This system will be undergoing maintenance April 18th between 9:00AM and 12:00PM CDT.

Search Results

open access

Diameter Measurements of Slugs Before and After Prolonged Heat Treatment

Description: Abstract: "Diameter measurements of 25 slugs taken before and after a prolonged heat treatment showed no evidence of differences that would indicate blistering. The average effects of the treatment was different for the various slugs. Large differences in diameter measurements between slugs. Large differences in diameter between slugs and significant differences between indices and positions were found."
Date: February 16, 1948
Creator: Bennett, Carl A. & Lane, J. J.
Partner: UNT Libraries Government Documents Department
open access

A Microdetermination of Uranium by Ferric Sulfate Titration

Description: Abstract: "Following nitrate removal by means of a three-stage hydrochloric acid digestion, uranium was reduced with chromous sulfate reagent. In an inert atmosphere, the quadrivalent uranium was titrated at 80-95[degrees] with standard ferric sulfate solution. The end point was obtained with a potentiometric cell including a platinum in-titrant reference electrode and a platinum indicator electrode. Application was made to various low leverl uranium solutions. For samples containing 1 - 12 mil… more
Date: February 16, 1949
Creator: Christopherson, E. W.
Partner: UNT Libraries Government Documents Department
open access

The Coulometric Titration of 8-Hydroxyquinoline

Description: Abstract: "A new method of determining 8-hydroxyquinoline by titration with electrolytucally-generated bromine has been developed. Results show good precision in the range 0.4 mg. to 1.6 mg. total 8-hydroxyquinoline, with 99% confidence limits of less than +/- 2%. An electronically-regulated constant current source, required by the method, is described. A new indicator system with high sensitivity to free bromine is discussed."
Date: June 16, 1949
Creator: Carson, W. N.
Partner: UNT Libraries Government Documents Department
open access

The Coulometric Determination of Acetic Acid

Description: Abstract: "Small amounts of acetic acid, equivalent to 400 ul. of 0.3 to 0.13 g/L. can be titrated coulonatrically in the presence of a 10 to 25-fold excess of HN03 in 70%, isopropanol. An accuracy of +/- 0.1% and a precision of +/- 8.5% (99% limite) are obtained.
Date: August 16, 1949
Creator: Carson, W. N. & Ko, Roy
Partner: UNT Libraries Government Documents Department
open access

Autoclaving of Anodized Slug Jackets

Description: The purpose of the test used to make this report was to determine if anodizing could become a part of the canning operation prior to autoclaving, other factors permitting, or if it must follow autoclaving.
Date: September 16, 1952
Creator: Dalrymple, R. S.
Partner: UNT Libraries Government Documents Department
open access

The Valve Actuated Pulse Column Design

Description: Abstract: "The valve-actuated pulse column is employed to give phase separation on each half cycle in the countercurrent flow cycle and provides independent control over each step in the cycle. The dependence on temperature of operation, on pulse frequency and amplitude, and on plate design and spacing has been studied for extraction and stripping of uranium with tributyl phosphate in a hydrocarbon diluent. It is found that the efficiency increases quite significantly as the temperature is rais… more
Date: February 16, 1953
Creator: Burger, L. L. & Clark, L. H.
Partner: UNT Libraries Government Documents Department
open access

A Description of the Acetone-Dye Solution Method of Demarcating a Leak Process Tubing While in the Pile

Description: Abstract: "A method has been devised and successfully used for marking a leaking pile process tube prior to its removal from the pile, such that subsequent location of the leak is more easily accomplished. An acetone solution of Testor's Dark Red Airplane Dope is poured into the suspect tube. The solution leaks from the hole and stains the surrounding area a light pink. To date the method has been used on tubes 3573F, 0486F, 0867F, and 3670F."
Date: July 16, 1952
Creator: DeHollander, W. R.
Partner: UNT Libraries Government Documents Department
open access

Tests and Application of Differential Pressure Micromanometer to 305 Building Instrumentation

Description: Report discussing tests conducted in an attempt to adapt a micromanometer for use in measuring variations of about 0.003 mm Hg in atmospheric pressure. Additionally, a method for making full use of the micromanometer sensitivity and extending its range is described.
Date: January 16, 1953
Creator: Hildreth, N. T.
Partner: UNT Libraries Government Documents Department
open access

Decontamination of Dissolver Vent Gases at Hanford

Description: The preceding report follows an extensive study made at Hanford of methods and equipment to remove effectively the dissolver vent gases.
Date: February 16, 1951
Creator: Blasewitz, A. G.; Carlisle, R. V.; Judson, B. F.; Katzer, M. F.; Kurtz, E. F.; Schmidt, W. C. et al.
Partner: UNT Libraries Government Documents Department
open access

Organic Continuous Cartridge for the Purex 2D Column

Description: This document covers work done in 3- and 4-inch-diameter glass columns directed toward the development of improved cartridges for the Purex Plant final uranium cycle extraction column, the 2D column. A nozzle plate cartridge for the extraction section and a mixed plate cartridge containing both stainless steel and fluorothene sieve plates for the scrub section were developed. In 3- and 4-inch-diameter glass columns these cartridges have a uranium extraction efficiency as good as or better than … more
Date: October 16, 1956
Creator: Hesson, G. M.
Partner: UNT Libraries Government Documents Department
open access

Minutes of Criticality Instrumentation Meeting Hanford Atomic Products Operation August 17 and 18, 1959

Description: At the request of the Hanford Operations Office of the Atomic Energy Commission, a criticality instrumentation meeting was held at Hanford on August 17 and 18, 1959. The purposes of the meeting were: (a) to review types of criticality control and/or alarm instrumentation at each site, their problems, shortcomings and potential obsolescence; (b) to discuss instrumentation in the area if approaching criticality; and (c) to consider for material balance purposes, the feasibility of devising instru… more
Date: September 16, 1959
Creator: Brown, C. L.
Partner: UNT Libraries Government Documents Department
open access

Exponential Pile Measurements in Water Moderated Lattices with Enriched Uranium Rods

Description: This paper presents the results of a series of buckling measurements involving the use of enriched uranium rods (1.007% by weight U²³⁵) in light water. The effect of replacing a water reflector with one of uranyl nitrate solution of two different concentrations, 536 and 188 grams of U per liter of solution was investigated for the 0.925" rods with the 1.74 H₂O/U-volume ratio in the core. Some information was also obtained on the extrapolation length to be used in unreflected cases. The applicat… more
Date: January 16, 1956
Creator: Clayton, E. D. & Neumann, H.
Partner: UNT Libraries Government Documents Department
open access

The Separation of Uranium and Plutonium Isotopes in Chemical Exchange Systems

Description: The purpose of this paper is to examine the theory and results of chemical exchange experiments for separation of heavy metal isotopes. The aim is to find a means of predicting those chemical exchange systems likely to produce large isotopic separation factors.
Date: May 16, 1955
Creator: Hahn, H. T.
Partner: UNT Libraries Government Documents Department
open access

Recommended Limit for Radioactive Liquid Disposal From Hanford Separations Plants to Surface Ponds

Description: The purpose of this report is to establish a practical control limit for the activity density (concentration) of radioactive material that may be permitted in large-volume waste waters discharged from the Hanford separations plants to open ponds on the surface of the ground nearby, in consideration of the radiological hazards,
Date: February 16, 1956
Creator: Clukey, H. V.
Partner: UNT Libraries Government Documents Department
open access

The Determination of Cu-64 in Reactor Effluent Water by Electrodeposition

Description: An analytical method for Cu-64 in reactor effluent has been studied based upon electrodeposition of the active copper with inert copper carrier. A two hour plating time was employed at a current density of 10 ma/sq cm and four volts across the cell. A stainless steel cathode plate was used. Carrier yields of greater than 80% were obtained with a standard deviation of the yield-corrected counting rate as low as 0.24%. Very little, if any contamination by other radioactive elements present wa… more
Date: September 16, 1953
Creator: Perkins, R. W. (Richard W.)
Partner: UNT Libraries Government Documents Department
open access

Some Comments on the Selection of Operating Temperatures for DPR

Description: The results of this investigation indicate that maximum electric power generation can be obtained by selecting the turbine steam temperature within a range of plus/minus 30 degrees C. from an "idealized" steam temperature. This "idealized" steam temperature is shown to depend primarily on the maximum permissible uranium temperature. The minimum available condenser temperature and the temperature rise of the coolant in the pile effect the selection of the turbine steam temperature to lesser ex… more
Date: November 16, 1953
Creator: Altmann, Manfred.
Partner: UNT Libraries Government Documents Department
open access

Filtration of Radioactive Aerosols by Glass Fibers: Part Two -- Appendices

Description: From introduction: "Five appendices, each of which pertains to a separate phase of the Filtration of Radioactive Aerosols by Glass Fibers program."
Date: April 16, 1951
Creator: Blasewitz, A. G.; Carlisle, R. V.; Judson, B. F.; Katzer, M. F.; Kurtz, E. F.; Schmidt, W. C. et al.
Partner: UNT Libraries Government Documents Department
open access

The Fission Cross Section f Factor of Pu²³⁹

Description: A presentation of the values for the Pu²³⁹ fission cross section f factor extended into a higher energy range than previously reported in BNL-250. The values were obtained by integrating the standard expression defining the f factor on the Hanford IBM-CPC equipment. The un-fit experimental data of Leonard, as corrected for resolution and doppler effect, was used above 0.03 ev being attached to an analytic fit applicable below this point. Results are shown on the accompanying graph.
Date: December 16, 1954
Creator: Stuart, G. W.
Partner: UNT Libraries Government Documents Department
open access

Specifications for WAPD Loop

Description: Specifications for the proposed in-pile loop to be placed in the Hanford Reactor. The the purpose of the proposed installation of an irradiation facility accounting to a high pressure, high temperature recirculating loop for the Westinghouse Atomic Power Division (WAPD) is to test the integrity of fuel specimens. This report, in support of the feasibility study, cost estimates, and schedule, presents design specifications for the loop.
Date: February 16, 1955
Creator: Berberet, J. A.
Partner: UNT Libraries Government Documents Department
open access

Preparation of Spherical Uranium Particles - Report of Invention

Description: This is a report of what may be an invention in a process or processes for preparing roughly spherical uranium metal particles suitable for use in matrix type nuclear reactor fuel elements.
Date: August 16, 1955
Creator: Roake, William Earl
Partner: UNT Libraries Government Documents Department
open access

A New Approach to Concatenation of Pulsed Columns

Description: A method of performing a series of solvent extractions using a minimum of pulse generators is briefly outlined.
Date: August 16, 1955
Creator: Ludlow, J. O.
Partner: UNT Libraries Government Documents Department
open access

An Evaluation of Monitoring Methods for NO and NO₂

Description: This report is a survey of methods for determining trace amounts of nitric oxide and nitrogen dioxide in air. The methods are evaluated in relation to their applicability to continuous monitoring procedures for these substances in stack gas and in air for human consumption.
Date: May 16, 1955
Creator: Kalkwarf, D. R.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen