Determination of Coefficients of Reactivity. Test Results DL-S-151 (T-550132). Section I. Fourth Performance
Description:
The purpose of the test was to determine the temperature and pressure coefficients of reactivity at sere power. The value for the temperature coefficient at the operating temperature of 523 F with 556.6 EFPH plant operation was 2.5 (delta E/F) x 16(-4). The magnitude of the temperature coefficient at the plant operating temperature (523 F) indicated the reactor is very stable during normal operations. The pressure coefficient varied from values of 1.41(deltaE/psig) x 10(-6) at 1437 psig to a.57…
more
Date:
January 31, 1959
Creator:
Baird, John B.
Partner:
UNT Libraries Government Documents Department