3 Matching Results

Search Results

15 Mile Road/Edison Corridor Sewer Tunnel Failure Study, Detroit Area, Michigan

Description: Partial abstract: "The study consisted of field and laboratory investigations, construction evaluation, and geotechnical and structural analyses to determine the cause(s) of distress and failure of a 2600-ft section of 12-ft 9-in. diameter concrete-lined sanitary sewer tunnel in the Detroit, Mich., area. [...] The report includes summaries of all pertinent construction records, results of all pertinent past and current field and laboratory tests on construction and geotechnical materials, and detailed geotechnical and structural analyses based on observed conditions and measured parameters."
Date: January 1981
Creator: Albert, Dick; Hoff, George C.; Lorence, Brian; Mitchell, Gerald B.; Mlakar, Paul F.; Murphy, William L. et al.
Partner: UNT Libraries Government Documents Department

Deterioration and Repair of Concrete in the Lower Monumental Navigation Lock Wall

Description: "This report discusses surface deterioration and repairs of concrete in the Lower Monumental Lock on the Snake River in Washington. It includes discussion of laboratory studies, testing, construction, and field evaluation of the original concrete and of the various cementitious coatings used for repairs" (p. i).
Date: June 1981
Creator: Schrader, Ernest K.
Partner: UNT Libraries Government Documents Department