1,4-diphenylbutadiyne as a potential tritium getter

Description: Research on the acetylene compound 1,4-diphenylbutadiyne is an effort to develop an air-operative tritium gas scavenger. T/sub 2/ adds to the acetylene bond of the organic in the presence of a metal catalyst. The catalyst also stimulates the oxidation reaction as well. The butadiyne compound has shown good reaction efficiency at 300 ppM T/sub 2/ in static dry air. At this concentration 75% of the scavenged tritium was in the organic. This work has expanded to the investigation of liquid acetyle… more
Date: October 1, 1980
Creator: Miller, H. H.; Bissell, E. E.; Tsugawa, R. T. & Souers, P. C.
Partner: UNT Libraries Government Documents Department
open access

2-D Simulations of Drainage Winds and Diffusion Compared to Observations

Description: A vertically integrated dynamical drainage flow model is developed from conservation equations for momentum and mass in a terrain-following coordinate system. Wind fields from the dynamical model drive a Monte Carlo transport and diffusion model. The model needs only topographic data, an Eulerian or Lagrangian time scale and a surface drag coefficient for input data, and can be started with a motionless atmosphere. Model wind and diffusion predictions are compared to observations from the rugge… more
Date: May 29, 2001
Creator: Garrett, A. J.
Partner: UNT Libraries Government Documents Department
open access

10-MW demonstration of the gas suspension absorption process at TVA`s Center for Emissions Research. Final report

Description: The Tennessee Valley Authority (TVA) in cooperation with AirPol Inc., and the U.S. Department of Energy (DOE), has recently completed a successful 17-month test program with the AirPol Gas Suspension Absorption (GSA) flue gas desulfurization (FGD) process at TVA`s Center for Emissions Research (CER). This project was selected by DOE for funding in the third round of the Clean Coal Technology Program. This 10-MW demonstration of the GSA FGD system at the CER was the first application of this tec… more
Date: March 1995
Partner: UNT Libraries Government Documents Department
open access

A 12-MW-scale pilot study of in-duct scrubbing (IDS) using a rotary atomizer

Description: A low-cost, moderate-removal efficiency, flue gas desulfurization (FGD) technology was selected by the US Department of Energy for pilot demonstration in its Acid Rain Precursor Control Technology Initiative. The process, identified as In-Duct Scrubbing (IDS), applies rotary atomizer techniques developed for lime-based spray dryer FGD while utilizing existing flue gas ductwork and particulate collectors. IDS technology is anticipated to result in a dry desulfurization process with a moderate re… more
Date: November 1, 1989
Creator: Samuel, E. A.; Murphy, K. R. & Demian, A.
Partner: UNT Libraries Government Documents Department
open access

A 12-MW-scale pilot study of in-duct scrubbing (IDS) using a rotary atomizer

Description: A low-cost, moderate-removal efficiency, flue gas desulfurization (FGD) technology was selected by the US Department of Energy for pilot demonstration in its Acid Rain Precursor Control Technology Initiative. The process, identified as In-Duct Scrubbing (IDS), applies rotary atomizer techniques developed for lime-based spray dryer FGD while utilizing existing flue gas ductwork and particulate collectors. IDS technology is anticipated to result in a dry desulfurization process with a moderate re… more
Date: November 1, 1989
Creator: Samuel, E. A.; Murphy, K. R. & Demian, A.
Partner: UNT Libraries Government Documents Department
open access

50,000 mile methanol/gasoline blend fleet study: a progress report

Description: Seven current production automobiles are being used in a fleet study to obtain operational experience in using 10% methanol/90% gasoline blends as an automotive fuel. Data from chassis dynamometer tests (run according to the 1975--1978 Federal test procedure) have been obtained, showing fuel economy and exhaust emissions of carbon monoxide, oxides of nitrogen, unburned fuel, methanol, and aldehydes. These data are shown for each of the vehicles when operated on the 10% methanol blend, and on un… more
Date: January 1, 1979
Creator: Stamper, K. R.
Partner: UNT Libraries Government Documents Department
open access

100 Area Excavation Treatability Test Plan

Description: This test plan documents the requirements for a treatability study on field radionuclide analysis and dust control techniques. These systems will be used during remedial actions involving excavation. The data from this treatability study will be used to support the feasibility study (FS) process. Development and screening of remedial alternatives for the 100 Area, using existing data, have been completed and are documented in the 100 Area Feasibility Study, Phases 1 and 2 (DOE-RL 1992a). Based … more
Date: May 1, 1993
Partner: UNT Libraries Government Documents Department
open access

180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO sub x ) emissions from coal-fired boilers

Description: ABB CE's Low NOx Bulk Furnace Staging (LNBFS) System and Low NOx Concentric Firing System (LNCFS) are demonstrated in stepwise fashion. These systems incorporate the concept of advanced overfire air (AOFA), clustered coal nozzles, and offset air. A complete description of the installed technologies is provided in the following section. The primary objective of the Plant Lansing Smith demonstration is to determine the long-term effects of commercially available tangentially-fired low NOx combust… more
Date: January 1, 1991
Partner: UNT Libraries Government Documents Department
open access

180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Final report

Description: This report provides the key findings of the Innovative Clean Coal Technology (ICCT) demonstration project at Gulf Power`s Lansing Smith Unit No. 2 and the implications for other tangentially-fired boilers. L. Smith Unit No. 2 is a 180 MW tangentially-fired boiler burning Eastern Bituminous coal, which was retrofitted with Asea Brown Boveri/Combustion Engineering Services` (ABB/CE) LNCFS I, II, and III technologies. An extensive test program was carried-out with US Department of Energy, Souther… more
Date: February 1, 1994
Creator: Tavoulareas, E. S.; Hardman, R.; Eskinazi, D. & Smith, L.
Partner: UNT Libraries Government Documents Department
open access

180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report second quarter, 1991

Description: ABB CE`s Low NOx Bulk Furnace Staging (LNBFS) System and Low NOx Concentric Firing System (LNCFS) are demonstrated in stepwise fashion. These systems incorporate the concept of advanced overfire air (AOFA), clustered coal nozzles, and offset air. A complete description of the installed technologies is provided in the following section. The primary objective of the Plant Lansing Smith demonstration is to determine the long-term effects of commercially available tangentially-fired low NOx combust… more
Date: December 31, 1991
Partner: UNT Libraries Government Documents Department
open access

250 MW single train CFB cogeneration facility. Annual report, October 1993--September 1994

Description: This Technical Progress Report (Draft) is submitted pursuant to the Terms and Conditions of Cooperative Agreement No. DE-FC21-90MC27403 between the Department of Energy (Morgantown Energy Technology Center) and York County Energy Partners, L.P. a wholly owned project company of Air Products and Chemicals, Inc. covering the period from January 1994 to the present for the York County Energy Partners CFB Cogeneration Project. The Technical Progress Report summarizes the work performed during the m… more
Date: February 1, 1995
Partner: UNT Libraries Government Documents Department
open access

291-B-1 stack monitoring and sampling system annual system assessment report

Description: The B Plant 291-B-1 main stack exhausts gaseous effluents to the atmosphere from the 221-B Building canyon and cells, the No. 1 Vessel Ventilation System (VVS1), the 212-B Cask Station cell ventilation system, and, to a limited capacity, the 224-B Building. VVS1 collects offgases from various process tanks in 221-B Building, while the 224-B system maintains a negative pressure in out-of-service, sealed process tanks. B Plant Administration Manual, WHC-CM-7-5, Section 5.30 requires an annual sys… more
Date: December 16, 1994
Creator: Ridge, T. M.
Partner: UNT Libraries Government Documents Department
open access

296-B-5 Stack monitoring and sampling system annual system assessment report

Description: The B Plant Administration Manual requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with Stack 296-B-5 at B Plant. The sampling and monitoring system associated with stack 296-B-5 is functional and performing satisfactorily. This document is an annual assessment report of the systems associated with the 296-B-5 stack.
Date: February 1995
Creator: Ridge, T. M.
Partner: UNT Libraries Government Documents Department
open access

296-B-13 stack monitoring and sampling system: Annual system assessment report

Description: This report presents the details of the annual system assessment of the air pollution monitoring and sampling system for the 296-13 stack at the Hanford site. Topics discussed include; system description, system status, system aging, spare parts considerations, long term maintenance plan, trends, and items requiring action.
Date: May 16, 1995
Creator: Ridge, T.M.
Partner: UNT Libraries Government Documents Department
open access

340 Facility compliance assessment

Description: This study provides an environmental compliance evaluation of the RLWS and the RPS systems of the 340 Facility. The emphasis of the evaluation centers on compliance with WAC requirements for hazardous and mixed waste facilities, federal regulations, and Westinghouse Hanford Company (WHC) requirements pertinent to the operation of the 340 Facility. The 340 Facility is not covered under either an interim status Part A permit or a RCRA Part B permit. The detailed discussion of compliance deficienc… more
Date: October 1, 1993
Creator: English, S. L.
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide emissions from coal-fired boilers

Description: Technology project demonstrating advanced wall-fired combustion techniques for the reduction of nitrogen oxide NOx emissions from coal-fired boilers. The primary objective of the demonstration is to determine the long-term NOx reduction performance of advanced overfire air (AOFA), low NOx burners (LNB), and advanced digital control/optimization methodologies applied in a stepwise fashion to a 500 MW boiler. The focus of this paper is to report (1) on the installation of three on-line carbon-in-… more
Date: September 1, 1995
Creator: Sorge, J.N.; Menzies, B.; Smouse, S.M. & Stallings, J.W.
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide emissions from coal-fired boilers

Description: This paper discusses the technical progress of a US Department of Energy Innovative Clean Coal Technology project demonstrating advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The primary objective of the demonstration is to determine the long-term NOx reduction performance of advanced overfire air (AOFA), low NOx burners (LNB), and advanced digital control/optimization methodologies applied in a stepwise fashion to a 500 MW… more
Date: November 1, 1994
Creator: Sorge, John N. & Wilson, Steve M.
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO[sub x]) emissions from coal-fired boilers

Description: The project provides a stepwise retrofit of an advanced overfire air (AOFA) system followed by low NO[sub x] burners (LNB). During each test phase of the project, diagnostic, performance, long-term, and verification testing will be performed. These tests are used to quantify the NO[sub x] reductions of each technology and evaluate the effects of those reductions on other combustion parameters such as particulatecharacteristics and boiler efficiency. Baseline, AOFA, and LNB without AOFA test seg… more
Date: January 1, 1992
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal fired boilers. Second quarterly technical progress report, [April--June 1993]

Description: The primary goal of this project is the characterization of the low NO{sub x} combustion equipment through the collection and analysis of long-term emissions data. A target of achieving fifty percent NO{sub x} reduction using combustion modifications has been established for the project. The project provides a stepwise retrofit of an advanced overfire air (AOFA) system followed by low NO{sub x} burners (LNB). During each test phase of the project, diagnostic, performance, long-term and verifica… more
Date: December 31, 1993
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report, fourth quarter 1995

Description: This document discusses the technical progress of a US Department of Energy (DOE) Innovative Clean Coal Technology (ICCT) Project demonstrating advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 (500 MW) near Rome, Georgia. Specifically, the objectives of the projects are: (1) demonstrate in a logical stepwise fashion the short-term NO{sub x} r… more
Date: December 31, 1995
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report, second quarter 1994, April 1994--June 1994

Description: This quarterly report discusses the technical progress of an Innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NOx combustion equipment through the collection and analysis of long-term emissions dat… more
Date: September 1, 1995
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report, second quarter 1995

Description: This quarterly report discusses the technical progress of an Innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NO{sub x} combustion equipment through the collection and analysis of long-term e… more
Date: December 31, 1995
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report, third quarter 1994, July 1994--September 1994

Description: This quarterly report discusses the technical progress of an Innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NOx combustion equipment through the collection and analysis of long-term emissions dat… more
Date: September 1, 1995
Partner: UNT Libraries Government Documents Department
open access

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Third quarterly progress report, 1992: Innovative Clean Coal Technology (ICCT)

Description: The project provides a stepwise retrofit of an advanced overfire air (AOFA) system followed by low NO{sub x} burners (LNB). During each test phase of the project, diagnostic, performance, long-term, and verification testing will be performed. These tests are used to quantify the NO{sub x} reductions of each technology and evaluate the effects of those reductions on other combustion parameters such as particulatecharacteristics and boiler efficiency. Baseline, AOFA, and LNB without AOFA test seg… more
Date: December 31, 1992
Partner: UNT Libraries Government Documents Department