Search Results

Advanced search parameters have been applied.
open access

Plutonium accident resistant container project

Description: The PARC (plutonium accident resistant container) project resulted in the design, development, and certification testing of a crashworthy air-transportable plutonium package (shipping container) for certification by the USNRC. This PAT-1 (plutonium air transportable) package survives a very severe sequential test program of impact, crush, puncture, slash, burn, and water immersion. There is also an individual hydrostatic pressure test. The package has a payload mass capacity of 2 kg of PuO2 and… more
Date: May 1, 1978
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Plutonium accident resistant container project. [Air transport]

Description: The PARC (plutonium accident resistant container) project resulted in the design, development, and certification testing of a crashworthy air-transportable plutonium package (shipping container) for certification by the USNRC (Nuclear Regulatory Commission). This PAT-1 (plutonium air transportable) package survives a very severe sequential test program of impact, crush, puncture, slash, burn, and water immersion. There is also an individual hydrostatic pressure test. The package has a payload m… more
Date: September 1, 1978
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

PAT-2 (Plutonium Air-Transportable Model 2) safety analysis report

Description: The PAT-2 package is designed for the safe transport of plutonium and/or uranium in small quantities. The PAT-2 package is resistant to severe accidents, including that of a high-speed jet aircraft crash, and is designed to withstand such environments as extreme impact, crushing, puncturing and slashing loads, severe hydrocarbon-fueled fires, and deep underwater immersion, with no escape of contents. The package meets the requirements of 10 CFR 71 for Fissile Class I packages with a cargo of 15… more
Date: July 1, 1981
Creator: Andersen, J. A.; Davis, E. J.; Duffey, T. A.; Dupree, S. A.; George, O. L. Jr. & Ortiz, Z.
Partner: UNT Libraries Government Documents Department
open access

Pu/U safeguards samples licensed for the PAT-2

Description: A development program for a Lightweight Air-transportable Accident Resistant Container (LAARC), to be used for the timely transport of plutonium or uranium safeguards samples to International Atomic Energy Agency (IAEA) laboratories, in support of the Non Proliferation Treaty (NPT), has resulted in the availability of the Plutonium Air Transportable Model 2 Package (PAT-2 Package). The PAT-2 can survive a severe aircraft crash and resulting fire, providing a virtually unassailable sealed pressu… more
Date: January 1, 1982
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Reduced-size plutonium sample processing and packaging for the PAT-2 package

Description: A light-water container for the air transport of plutonium safeguards samples, the PAT-2 package, has been developed in the USA and is now licensed by the US NRC (Certificate of Compliance) and the US DOT (IAEA Certificate of Competent Authority). The very limited available space in this package for plutonium-bearing samples required the design of small-size canisters to meet the needs of international safeguards. The suitability of a new small canister and vial for powder and solution samples … more
Date: January 1, 1982
Creator: Kuhn, E.; Deron, S.; Aigner, H. & Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Engineering task plan for determining breathing rates in singleshell tanks using tracer gas

Description: The testing of single shell tanks to determine breathing rates. Inert tracer gases helium, and sulfur hexafluoride will be injected into the tanks AX-103, BY-105, C-107 and U-103. Periodic samples will be taken over a three month interval to determine actual headspace breathing rates.
Date: April 2, 1997
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Engineering work plan and design basis for 241-SY ventilation improvements

Description: There are three tanks in the 241-SY tank farm. Tank 241-SY101 and 241-SY-103 are flammable gas watch list tanks. Tank 241-SY-102 is included in the ventilation improvement process in an effort to further control air flow in the tank farm. This tank farm has only one outlet ventilation port for all three tanks. Flammable gas is released (may be steady and/or periodic) from the waste in the primary tank vapor space. The gas is removed from the tank by an active ventilation system. However, mainta… more
Date: May 19, 1997
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Test plan for determining breathing rates in single shell tanksusing tracer gases. Revision 1

Description: This test plan specifies the requirements and conditions for the injection of tracer gas (Helium (He)) into single shell tanks to determine breathing rates using periodic sampling. The eight tanks which have been selected at the time this Test Plan was developed are A-101, AX-102, AX-103, BY-105, C-107, U-103 (U-103 is counted twice, once during the winter months and once during the summer), and U-105. Other tanks to be sampled will be assigned by Pacific Northwest National Laboratory (PNNL) at… more
Date: June 20, 1997
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
open access

Test plan for determining breathing rates in single shell tanksusing tracer gases. Revision 2

Description: This test plan specifies the requirements and conditions for the injection of tracer gases into eight tanks. Eight single shell tanks shall be injected with inert tracer gas, Helium (He), and then samples taken periodically to measure breathing rates. The eight tanks to be tested are; A-101, AX-102, AX-103, BY-105, C-107, U-103 (tested once in the winter and will be tested once in the summer), and U-105. The headspace of these tanks shall be sampled and analyzed periodically to obtain breathing… more
Date: June 26, 1997
Creator: Andersen, J. A.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen