Soil corrosion monitoring near a pipeline under CP
Description:
Electrochemical noise (EN), linear polarization resistance (LPR), and harmonic distortion analysis (HDA) were used with three-electrode probes to monitor the corrosion occurring in soil in dry and wet conditions near a gas pipeline under cathodic protection. The test site was a cathodic protection (CP) test station where impressed current CP was applied to a 2 in. (5.1 cm) diameter FBE coated steel pipe using an 84 in. (0.2 m) TA-2 high-silicon cast iron anode. Electrochemical measurements were…
more
Date:
January 1, 2005
Creator:
Bullard, Sophie J.; Covino, Bernard S., Jr.; Cramer, Stephen D.; Holcomb, Gordon R.; Ziomek-Moroz, Margaret; Locke, M. L. et al.
Item Type: