NACA Conference on Aerodynamics of High Speed Aircraft

Description: This document contains reproductions of technical papers presented by staff members of the NACA Laboratories at the NACA Conference on Aerodynamics of High-Speed Aircraft held at the Langley Aeronautical Laboratory November 1, 2, and 3, 1955. The primary purpose of the conference was to convey to contractors of the military services and others concerned with the design of aircraft the results of recent research and to provide those attending with an opportunity to discuss these results. The papers in this document are in the same form in which they were orally presented at the conference to facilitate their prompt distribution. The original presentation and this record are considered as complementary to, rather than as substitutes for, the Committee's more complete and formal reports.
Date: November 1, 1955
Partner: UNT Libraries Government Documents Department

Analysis of a Pneumatic Probe for Measuring Exhaust-Gas Temperatures with Some Preliminary Experimental Results

Description: A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy.
Date: May 21, 1952
Creator: Scadron, Marvin D.
Partner: UNT Libraries Government Documents Department

Investigation of Ejection Releases of an MB-1 Rocket from a 0.04956-Scaled Model of the Convair F-106A Airplane at Several Mach Numbers and Simulated Altitudes

Description: As a continuation of an investigation of the ejection release characteristics of an internally carried MB-1 rocket in the Convair F-106A airplane, fin modifications at additional Mach numbers and simulated altitudes have been studied in the 27- by 27-inch preflight jet of the Langley Pilotless Aircraft Research Station at Wallops Island, Va. The MB-1 rocket was ejected with fins open, fins closed, fins closed with a shroud around the fins, and fins folded with a "boattail" placed in between the fins. Dynamically scaled models (0.0^956 scale) were tested at simulated altitudes of 12,000, 18,850, and 27,500 feet at subsonic Mach numbers and at 18,850, 27,500, and 40,000 feet for Mach numbers of 1-39, 1-59, and 1.98. Successful ejections can be obtained for over 10 store diameters from release point by the use of a shroud around the folded fins with the proper ejection velocity and nose-down pitching moment at release. In one case investigated it was found desirable to close off the front one-third of the bomb bay. It appeared that the fins should be opened after release and within 5 "to 6 rocket diameters if no modifications are made on the rocket. An increase in fuselage angle of attack caused higher nose-up pitch rates after release.
Date: August 22, 1957
Creator: Lee, J. B. & Basford, R. C.
Partner: UNT Libraries Government Documents Department

Investigations of Air-Cooled Turbine Rotors for Turbojet Engines. 1: Experimental Disk Temperature Distribution in Modified J33 Split-Disk Rotor at Speeds up to 6000 RPM

Description: An experimental investigation is being conducted at the Lewis laboratory to establish general principles for the design of noncritical turbine rotor configurations. This investigation includes evaluation of cooling effectiveness, structural stability, cooling-air flow distribution characteristics, and methods of supplying cooling air to the turbine rotor blades. Prior to design of a noncritical rotor, a standard turbine rotor of a commerical turbojet engine was split in the plane of rotation and machined to provide a passage for distributing cooling air to the base of each blade. The rotor was fitted with nontwisted, hollow, aircooled blades containing nine tubes in the coolant passage. In the investigation reported herein, the modified turbine rotor operated successfully up to speeds of 6000 rpm with ratios of cooling-air to combustion-gas flow as low as 0.02. The disk temperatures observed at these conditions were below 450 0 F when cooling air at 100 F was used from the laboratory air system. The calculated disk temperatures based on the correlation method presented for rated engine conditions were well below 1000 F at a cooling-air flow ratio of 0.02, which is considered adequate for a noncritical rotor. An appreciable difference in temperature level existed between the forward and rear disks. This temperature difference probably introduced undesirable disk stress distributions as a result of the relative elongations of the two disks. This investigation was terminated at 6000 rpm so that slight changes in the engine configuration could be made to relieve this condition.
Date: January 9, 1952
Creator: Schramm, Wilson B. & Ziemer, Robert R.
Partner: UNT Libraries Government Documents Department

Experimental and Analytical Study of Balanced-Diaphragm Fuel Distributors for Gas-Turbine Engines

Description: A method of distributing fuel equally to a plurality of spray nozzles in a gas-turbine engine by means of balanced-diaphragm fuel distributors is presented. The experimental performance of three of eight possible distributor arrangements are discussed. An analysis of all eight arrangements is included. Criterions are given for choosing a fuel-distributor arrangement to meet specific fuel-system requirements of fuel-distribution accuracy, spray-nozzle pressure variations, and fuel-system pressures. Data obtained with a model of one distributor arrangement indicated a maximum deviation from perfect distribution of 3.3 percent for a 44 to 1 range (19.5 to 862 lb/hr) of fuel-flow rates. The maximum distributor pressure drop was 125 pounds per square inch. The method used to obtain the required wide range of flow control in the distributor valves consisted in varying the length of a constant-area flow path.
Date: August 14, 1950
Creator: Straight, David M. & Gold, Harold