9 Matching Results

Search Results

THE USE OF DI WATER TO MITIGATE DUSTING FOR ADDITION OF DWPF FRIT TO THE SLURRY MIX EVAPORATOR

Description: The Defense Waste Processing Facility (DPWF) presently is in the process to determine means to reduce water utilization in the Slurry Mix Evaporator (SME) process, thus reducing effluent and processing times. The frit slurry addition system mixes the dry frit with water, yielding approximately a 50 weight percent slurry containing frit and the other fraction water. This slurry is discharged into the SME and excess water is removed via boiling. To reduce this water load to the SME, DWPF has proposed using a pneumatic system in conveying the frit to the SME, in essence a dry delivery system. The problem associated with utilizing a dry delivery system with the existing frit is the generation of dust when discharged into the SME. The use of water has been shown to be effective in the mining industry as well in the DOE complex to mitigate dusting. The method employed by SRNL to determine the quantity of water to mitigate dusting in dry powders was effective, between a lab and bench scale tests. In those tests, it was shown that as high as five weight percent (wt%) of water addition was required to mitigate dust from batches of glass forming minerals used by the Waste Treatment Plant at Hanford, Washington. The same method used to determine the quantity of water to mitigate dusting was used in this task to determine the quantity of water to mitigate this dusting using as-received frit. The ability for water to mitigate dusting is due to its adhesive properties as shown in Figure 1-1. Wetting the frit particles allows for the smaller frit particles (including dust) to adhere to the larger frit particles or to agglomerate into large particles. Fluids other than water can also be used, but their adhesive properties are different than water and the quantity ...
Date: July 21, 2010
Creator: Hansen, E.
Partner: UNT Libraries Government Documents Department

Mixing Envelope D Sludge with LAW Intermediate Products with and without Glass Formers

Description: The Department of Energy (DOE) Office of River Protection is in the process of designing a waste treatment system to process the Hanford Reservation High Level Waste (HLW). Envelope D sludge slurries will be blended with the concentrated Cs/Ts eluates, and the Sr/TRU intermediates separated from Envelope A, B, and C feeds. This study produced two washed simulated sludges (representing tanks 241-AZ-101 and 241-AZ-102 sludge), a Sr/TRU washed precipitate produced from tank 241-AN-107 simulant, and a concentrated blended eluate simulant based upon eluates from processing 241-AZ-102 supernate.
Date: September 21, 2001
Creator: Hansen, E.K.
Partner: UNT Libraries Government Documents Department

Cygnus PFL Switch Jitter

Description: The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources: Cygnus 1 and Cygnus 2. Each source has the following X-ray output: 1-mm diameter spot size, 4 rads at 1 m, 50-ns full-widthhalf-maximum. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. This Radiographic Facility is located in an underground tunnel test area at the Nevada Test Site (NTS). The sources were developed to produce high-resolution images on subcritical tests performed at NTS. Subcritical tests are single-shot, high-value events. For this application, it is desirable to maintain a high level of reproducibility in source output. The major components of the Cygnus machines are Marx generator, water-filled pulse forming line (PFL), water-filled coaxial transmission line, threecell inductive voltage adder, and rod-pinch diode. A primary source of fluctuation in Cygnus shot-to-shot performance may be jitter in breakdown of the main PFL switch, which is a “self-break” switch. The PFL switch breakdown time determines the peak PFL charging voltage, which ultimately affects the source X-ray spectrum and dose. Therefore, PFL switch jitter may contribute to shot-to-shot variation in these parameters, which are crucial to radiographic quality. In this paper we will present PFL switch jitter analysis for both Cygnus machines and present the correlation with dose. For this analysis, the PFL switch on each machine was maintained at a single gap setting, which has been used for the majority of shots at NTS. In addition the PFL switch performance for one larger switch gap setting will be examined.
Date: July 21, 2007
Creator: Mitton, C.; Corrow, G. & Henderson, D.
Partner: UNT Libraries Government Documents Department

IMPACT OF ALUMINATE IONS ON THE PROPERTIES OF SALTSTONE GROUT MIXES

Description: It is important to identify and control the operational and compositional variables that impact the important processing and performance properties of Saltstone grout mixes. The grout that is produced at the Saltstone Production Facility (SPF) is referred to as Saltstone and is a waste form that immobilizes low concentrations of radionuclides as well as certain toxic metals. The Saltstone will be disposed of in vaults at Savannah River Site (SRS). An effort referred to as the Saltstone Variability Study has been initiated to achieve this goal. The protocols developed in this variability study are also ideally suited as a tool to assess the impact of proposed changes to the processing flow sheet for Liquid Waste Operations at SRS. One such proposal that is currently under consideration is to introduce a leaching step in the treatment of the High Level Waste (HLW) sludge to remove aluminum prior to vitrification at the Defense Waste Processing Facility (DWPF). This leachate would significantly increase the soluble aluminate concentration in the salt feed that will be processed at the SPF. Consequently, an initial study of the impact of increased aluminate concentration on the Saltstone grout properties was performed. Prior work by Lukens (1) showed that aluminate in the salt solutions increases the amount of heat generation.
Date: February 21, 2008
Creator: Harbour, J; Tommy Edwards, T; Erich Hansen, E & Vickie Williams, V
Partner: UNT Libraries Government Documents Department

PREPARATION AND CHARACTERIZATION OF POROUS WALLED HOLLOW GLASS MICROSPHERES

Description: Porous-walled hollow glass microspheres (PWHGMs) of a modified alkali borosilicate composition have been successfully fabricated by combining the technology of producing hollow glass microspheres (HGMs) with the knowledge associated with porous glasses. HGMs are first formed by a powder glass--flame process, which are then transformed to PWHGMs by heat treatment and subsequent treatment in acid. Pore diameter and pore volume are most influenced by heat treatment temperature. Pore diameter is increased by a factor of 10 when samples are heat treated prior to acid leaching; 100 {angstrom} in non-heat treated samples to 1000 {angstrom} in samples heat treated at 600 C for 8 hours. As heat treatment time is increased from 8 hours to 24 hours there is a slight shift increase in pore diameter and little or no change in pore volume.
Date: April 21, 2008
Creator: Raszewski, F; Erich Hansen, E; Ray Schumacher, R & David Peeler, D
Partner: UNT Libraries Government Documents Department

A new method to generate dust with astrophysical properties

Description: In interstellar and interplanetary space, the size distribution and composition of dust grains play an important role. For example, dust grains determine optical and ultraviolet extinction levels in astronomical observations, dominate the cooling rate of our Galaxy, and sets the thermal balance and radiative cooling rates in molecular clouds, which are the birth place of stars. Dust grains are also a source of damage and failure to space hardware and thus present a hazard to space flight. To model the size distribution and composition of dust grains, and their effect in the above scenarios, it is vital to understand the mechanism of dust-shock interaction. We demonstrate a new experiment which employs a laser to subject dust grains to pressure spikes similar to those of colliding astrophysical dust, and which accelerates the grains to astrophysical velocities. The new method generates much larger data sets than earlier methods; we show how large quantities (thousands) of grains are accelerated at once, rather than accelerating individual grains, as is the case of earlier methods using electric fields.
Date: April 21, 2010
Creator: Hansen, J F; van Breugel, W; Bringa, E M; Graham, G A; Remington, B A; Taylor, E A et al.
Partner: UNT Libraries Government Documents Department

Transportable Vitrification System: Operational experience gained during vitrification of simulated mixed waste

Description: The Transportable Vitrification System (TVS) is a large-scale, fully-integrated, transportable, vitrification system for the treatment of low-level nuclear and mixed wastes in the form of sludges, soils, incinerator ash, and similar waste streams. The TVS was built to demonstrate the vitrification of actual mixed waste at U. S. Department of Energy (DOE) sites. Currently, Westinghouse Savannah River Company (WSRC) is working with Lockheed Martin Energy Systems (LMES) to apply field scale vitrification to actual mixed waste at Oak Ridge Reservation`s (ORR) K-25 Site. Prior to the application of the TVS to actual mixed waste it was tested on simulated K-25 B and C Pond waste at Clemson University. This paper describes the results of that testing and preparations for the demonstration on actual mixed waste.
Date: November 21, 1996
Creator: Whitehouse, J.C.; Burket, P.R.; Crowley, D.A.; Hansen, E.K.; Jantzen, C.M.; Smith, M.E. et al.
Partner: UNT Libraries Government Documents Department

Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems

Description: This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested.
Date: September 21, 1999
Creator: McNutt, P.; Kroposki, B.; Hansen, R.; DeBlasio, R. (National Renewable Energy Laboratory); Thomas, M. (Sandia National Laboratories); Durand, S. (Florida Solar Energy Center) et al.
Partner: UNT Libraries Government Documents Department