WR15 Microwave Calorimeter and Bolometer Unit

Description: Descriptions of the principal changes in the calorimeter and bolometer unit from the WR28 models of a microwave serving as National Bureau of Standards standard for power measurements in the frequency range 50 to 75 GHz.
Date: May 1972
Creator: Harvey, Morris E.
Partner: UNT Libraries Government Documents Department

WR 10 Millimeter Wave Microcalorimeter

Description: Abstract: A microcalorimeter has been built in WR 10 waveguide, 75-110 GHz, to serve as a power standard at the National Bureau of Standards (NBS). Included here is an evaluation of the errors in using the microcalorimeter for the measurement of effective efficiency of bolometer mounts. The error analysis shows a systematic uncertainty of +/- .83 percent and a random uncertainty of .37 percent.
Date: June 1981
Creator: Weidman, Manly P. & Hudson, Paul A.
Partner: UNT Libraries Government Documents Department

User's Guide for the Cone Calorimeter

Description: Abstract: This document provides instructions for users of the Cone Calorimeter in installing, operating, maintaining, and repairing the instrument. It is intended for training new operators at NBS and at other laboratories. The troubleshooting and repair sections will be a useful reference section even for experienced operators, since remedies for a large number of potential instrument malfunctions are outlined there.
Date: 1988
Creator: Twilley, William H. & Babrauskas, Vytenis
Partner: UNT Libraries Government Documents Department

Test and Evaluation of the Argonne BPAC10 Series Air Chamber Calorimeter Designed for 20 Minute Measurements

Description: This paper is the final report on DOE-OSS Task ANLE88002 Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software and discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software.
Date: October 1990
Creator: Perry, R. B.; Fiarman, Sidney; Jung, Erwin A. & Cremers, Teresa
Partner: UNT Libraries Government Documents Department

Coal Liquefaction Support Studies

Description: A development program is being carried out to obtain information applicable to the SYNTHOIL process for converting coal to liquid fuel of low sulfur content. This report presents information on (1) the design of a calorimeter to measure heat of reaction of hydrogen with coal slurries, (2) the design of apparatus and calculations for measuring coefficients of heat transfer from SYNTHOIL process feed and effluent products to process vessel walls, (3) tests on the use of additives to facilitate the removal of solids from oil produced in coal liquefaction processes, and (4) the design and construction of a test unit for evaluating new catalysts for coal liquefaction processes.
Date: 1976?
Creator: Fischer, J.; Bump, T. R.; Mulcahey, T. P.; Jonke, A. A.; Lo, R.; Nandi, S. et al.
Partner: UNT Libraries Government Documents Department

Coal Liquefaction Support Studies

Description: A development program is being carried out to obtain information applicable to the SYNTHOIL process for converting coal to liquid fuel of low sulfur content. This report presents information on (1) the design of a calorimeter to measure heat of reaction of hydrogen with coal slurries, (2) the design of apparatus and calculations for measuring coefficients of heat transfer from SYNTHOIL process feed and effluent products to process vessel walls, (3) tests on the use of additives to facilitate the removal of solids from oil produced in coal liquefaction processes, and (4) the design and construction of a test unit for evaluating new catalysts for coal liquefaction processes.
Date: 1977?
Creator: Fischer, J.; Bump, T. R.; Mulcahey, T. P.; Jonke, A. A.; Lo, R.; Nandi, S. et al.
Partner: UNT Libraries Government Documents Department

Coal Liquefaction Support Studies

Description: A development program is being carried out to obtain information applicable to the SYNTHOIL process for converting coal to liquid fuel of low sulfur content. This report presents information on (1) the design of a calorimeter to measure heat of reaction of hydrogen with coal slurries, (2) the design of apparatus and calculations for measuring coefficients of heat transfer from SYNTHOIL process feed and effluent products to process vessel walls, (3) tests on the use of additives to facilitate the removal of solids from oil produced in coal liquefaction processes, and (4) the design and construction of a test unit for evaluating new catalysts for coal liquefaction processes.
Date: 1977?
Creator: Fischer, J.; Bump, T. R.; Mulcahey, T. P.; Jonke, A. A.; Lo, R.; Nandi, S. et al.
Partner: UNT Libraries Government Documents Department

Coal Liquefaction Support Studies

Description: A development program is being carried out to obtain information applicable to the SYNTHOIL process for converting coal to liquid fuel of low sulfur content. This report presents information on (1) the design of a calorimeter to measure heat of reaction of hydrogen with coal slurries, (2) the design of apparatus and calculations for measuring coefficients of heat transfer from SYNTHOIL process feed and effluent products to process vessel walls, (3) tests on the use of additives to facilitate the removal of solids from oil produced in coal liquefaction processes, and (4) the design and construction of a test unit for evaluating new catalysts for coal liquefaction processes.
Date: 1976?
Creator: Fischer, J.; Bump, T. R.; Mulcahey, T. P.; Jonke, A. A.; Lo, R.; Nandi, S. et al.
Partner: UNT Libraries Government Documents Department