3 Matching Results

Search Results

Advanced search parameters have been applied.

Selected Component Failure Rate Values from Fusion Safety Assessment Tasks

Description: This report is a compilation of component failure rate and repair rate values that can be used in magnetic fusion safety assessment tasks. Several safety systems are examined, such as gas cleanup systems and plasma shutdown systems. Vacuum system component reliability values, including large vacuum chambers, have been reviewed. Values for water cooling system components have also been reported here. The report concludes with the examination of some equipment important to personnel safety, atmospheres, combustible gases, and airborne releases of radioactivity. These data should be useful to system designers to calculate scoping values for the availability and repair intervals for their systems, and for probabilistic safety or risk analysts to assess fusion systems for safety of the public and the workers.
Date: September 1, 1998
Creator: Cadwallader, Lee Charles
Partner: UNT Libraries Government Documents Department

Ventilation Systems Operating Experience Review for Fusion Applications

Description: This report is a collection and review of system operation and failure experiences for air ventilation systems in nuclear facilities. These experiences are applicable for magnetic and inertial fusion facilities since air ventilation systems are support systems that can be considered generic to nuclear facilities. The report contains descriptions of ventilation system components, operating experiences with these systems, component failure rates, and component repair times. Since ventilation systems have a role in mitigating accident releases in nuclear facilities, these data are useful in safety analysis and risk assessment of public safety. An effort has also been given to identifying any safety issues with personnel operating or maintaining ventilation systems. Finally, the recommended failure data were compared to an independent data set to determine the accuracy of individual values. This comparison is useful for the International Energy Agency task on fusion component failure rate data collection.
Date: December 1, 1999
Creator: Cadwallader, Lee Charles
Partner: UNT Libraries Government Documents Department

Selected component failure rate values from fusion safety assessment tasks

Description: This report is a compilation of component failure rate and repair rate values that can be used in magnetic fusion safety assessment tasks. Several safety systems are examined, such as gas cleanup systems and plasma shutdown systems. Vacuum system component reliability values, including large vacuum chambers, have been reviewed. Values for water cooling system components have also been reported here. The report concludes with the examination of some equipment important to personnel safety, atmospheres, combustible gases, and airborne releases of radioactivity. These data should be useful to system designers to calculate scoping values for the availability and repair intervals for their systems, and for probabilistic safety or risk analysts to assess fusion systems for safety of the public and the workers.
Date: September 1, 1998
Creator: Cadwallader, L.C.
Partner: UNT Libraries Government Documents Department