Stress analysis of portable safety platform (Core Sampler Truck)

Description: This document provides the stress analysis and evaluation of the portable platform of the rotary mode core sampler truck No. 2 (RMCST {number_sign}2). The platform comprises railing, posts, deck, legs, and a portable ladder; it is restrained from lateral motion by means of two brackets added to the drill-head service platform.
Date: March 30, 1995
Creator: Ziada, H. H.
Partner: UNT Libraries Government Documents Department

Data quality objective to support resolution of the organic fuel rich tank safety issue

Description: During years of Hanford process history, large quantities of complexants used in waste management operations as well as an unknown quantity of degradation products of the solvents used in fuel reprocessing and metal recovery were added to man of the 149 single-shell tanks. These waste tanks also contain a presumed stoichiometric excess of sodium nitrate/nitrite oxidizers, sufficient to exothermically oxidize the organic compounds if suitably initiated. This DQO identifies the questions that must be answered to appropriately disposition organic watchlist tanks, identifies a strategy to deal with false positive or negative judgements associated with analytical uncertainty, and list the analytes of concern to support dealing with organic watchlist concerns. Uncertainties associated with both assay limitations and matrix effects complicate selection of analytes. This results in requiring at least two independent measures of potential fuel reactivity.
Date: April 28, 1995
Creator: Buckley, L.L.
Partner: UNT Libraries Government Documents Department

Recycle Waste Collection Tank (RWCT) simulant testing in the PVTD feed preparation system

Description: (This is part of the radwaste vitrification program at Hanford.) RWCT was to routinely receive final canister decontamination sand blast frit and rinse water, Decontamination Waste Treatment Tank bottoms, and melter off-gas Submerged Bed Scrubber filter cake. In order to address the design needs of the RWCT system to meet performance levels, the PNL Vitrification Technology (PVTD) program used the Feed Preparation Test System (FPTS) to evaluate its equipment and performance for a simulant of RWCT slurry. (FPTS is an adaptation of the Defense Waste Processing Facility feed preparation system and represents the initially proposed Hanford Waste Vitrification Plant feed preparation system designed by Fluor-Daniel, Inc.) The following were determined: mixing performance, pump priming, pump performance, simulant flow characterization, evaporator and condenser performance, and ammonia dispersion. The RWCT test had two runs, one with and one without tank baffles.
Date: March 1, 1996
Creator: Abrigo, G.P.; Daume, J.T.; Halstead, S.D.; Myers, R.L.; Beckette, M.R.; Freeman, C.J. et al.
Partner: UNT Libraries Government Documents Department

Designation of waste receipt assay and storage portions of WRAP as a limited control facility

Description: This evaluation designates the waste receipt, storage, assay, and shiping portions of WRAP I as a Limited Control Facility. The technical basis for this designation comes from CSERs in other facilities The limits and controls for this CSER come from other facilities. This is deemed sufficient, since any fissile material being received at WRAP I, will come from those facilities, and as long as the limits for limited control are maintained, the areas considered in this CSER can be designated appropriately.
Date: September 20, 1996
Creator: Ruben, R.H.
Partner: UNT Libraries Government Documents Department

241-SY-101 mulitport riser acceptance for beneficial use

Description: This document formally demonstrates that the Acceptance for Beneficial USE (ABU) process for the SY tank farm Multiport Riser assembly has been properly completed in accordance with the ABU checklist. For each item required on the ABU checklist, a bibliography of the documentation prepared and released to satisfy the requirement is provided
Date: October 2, 1995
Creator: Mendoza, R.E.
Partner: UNT Libraries Government Documents Department

340 Waste handling facility deactivation plan

Description: This document provides an overview of both the present status of the 340 Complex (within Hanford`s 300 Area), and of tasks associated with the deactivation of segments associated with radioactive, mixed liquid waste receipt, storage, and shipping. The plan also describes activities that will allow portions of the 340 Complex to remain in service.
Date: December 27, 1996
Creator: Stordeur, R.T., Westinghouse Hanford
Partner: UNT Libraries Government Documents Department

340 Waste handling facility interim safety basis

Description: This document presents an interim safety basis for the 340 Waste Handling Facility classifying the 340 Facility as a Hazard Category 3 facility. The hazard analysis quantifies the operating safety envelop for this facility and demonstrates that the facility can be operated without a significant threat to onsite or offsite people.
Date: October 4, 1996
Creator: Stordeur, R.T.
Partner: UNT Libraries Government Documents Department

Test report - caustic addition system operability test procedure

Description: This Operability Test Report documents the test results of test procedure WHC-SD-WM-OTP-167 ``Caustic Addition System Operability Test Procedure``. The Objective of the test was to verify the operability of the 241-AN-107 Caustic Addition System. The objective of the test was met
Date: October 13, 1995
Creator: Parazin, R.E.
Partner: UNT Libraries Government Documents Department

W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)

Description: Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.
Date: February 14, 1997
Creator: Watson, T.L., Fluor Daniel Hanford
Partner: UNT Libraries Government Documents Department

Baseline comparison report for Project W-058, Replacement of the cross-site transfer system. Revision 1

Description: This BCR compares the Project W-058 Functional Design Criteria with the Project W-058 Preliminary Design Requirements Document, and identifies the differences between the two documents in the mission definition, project requirements, system functions, and interfaces. Impacts these differences have on current project design are also discussed.
Date: December 1, 1995
Creator: Mendoza, D.P.
Partner: UNT Libraries Government Documents Department

Documentation associated with the WESF preparation for receiving 25 cesium capsules from the Applied Radiant Energy Corporation (ARECO)

Description: The purpose of this report is to compile all documentation associated with facility preparation of WESF to receive 25 cesium capsules from ARECO. The WESF validated it`s preparedness by completing a facility preparedness review using a performance indicator checklist.
Date: October 21, 1996
Creator: Pawlak, M.W.
Partner: UNT Libraries Government Documents Department

Final report for tank 241-BX-112, auger samples 95-Aug-047 and 95-Aug-048

Description: This document serves as the final report for Tank 241-BX-112. The auger samples were taken on Nov. 16 and 17, 1995. The report is broken into 2 parts; the nd part consists of the original 45-day safety screening report (including the DSC and TGA raw data). Prior to auger sampling, the vapor space of tank BX-112 was screened for flammability issues; the vapor space was found to be far below the lower explosive limit. The auger samples were taken to fully satisfy the DQO.
Date: February 29, 1996
Creator: Conner, J.M.
Partner: UNT Libraries Government Documents Department

Operational readiness review phase-1 final report for WRAP-1

Description: This report documents the Operational Readiness Review for WRAP-1 Phase-1 operations. The report includes all criteria, lines of inquiry with resulting Findings and Observations. The review included assessing operational capability of the organization and the computer controlled process and facility systems.
Date: December 27, 1996
Creator: Bowen, W., Westinghouse Hanford
Partner: UNT Libraries Government Documents Department

Engineering Task Plan for simulated riser installation by use of rotary drilling

Description: This task is being performed to demonstrate the feasibility of the best riser installation alternative identified in the Engineering Study. This Engineering Task Plan (ETP) will be the WHC project management plan for the riser installation demonstration activities.
Date: December 1, 1995
Creator: Barnes, G. A.
Partner: UNT Libraries Government Documents Department

TMACS system description

Description: This document provides a description of the Tank Monitor and Control System (TMACS). It is intended as an introduction for those persons unfamiliar with the system as well as a reference document for the users, maintenance personnel, and system designers. In addition to describing the system, the document outlines the associated drawing documentation, provides maintenance and spare parts information, and discusses other TMACS documents that provide additional detail
Date: October 17, 1995
Creator: Scaief, C.C.
Partner: UNT Libraries Government Documents Department

W-026 acceptance test report system integration equipment (SIE)(submittal {number_sign} 018.6.A)

Description: Acceptance testing of the System Integration Equipment (SIE) at Hanford was performed in two stages. The first was inconclusive, and resulted in a number of findings. These finding. are summarized as part of this report. The second stage of testing addressed these findings, and performed full system testing per the approved test procedure. This report includes summaries of all testing, results and finding.. Although the SIE did not in some cases perform as required for plant operations, it did perform per the system specification. (These discrepancies were noted and are addressed elsewhere.) Following testing, the system was formaLLy accepted. Documentation of this acceptance is incLuded in this report.
Date: January 27, 1997
Creator: Watson, T.L.
Partner: UNT Libraries Government Documents Department