Modified Purification System Performance Test. Core 1, Seed 2. Test Results T-641124-A. Section 2
Description:
The effectiveness of purification in controlling plant radioactivation rates was determined through comparison of the actual effects produced from plant operation with and without purification. With the purification system in service, there was no appreciable difficulty in maintaining the reactor coolant within reference water specifications. In addition, there was no discernible increase of crud deposition in the coolant system as determined by direct radiation measurements of the purification…