54 Matching Results

Search Results

Advanced search parameters have been applied.

Supplement to Recommended Minimum Requirements for Plumbing: Progress Revision, May, 1931

Description: Report issued by the Bureau of Standards discussing revisions and supplements made to minimum plumbing requirements for residential and commercial buildings. The revisions and supplements to previous reports are presented. This report includes tables, and illustrations.
Date: 1931
Creator: United States. Bureau of Standards.
Partner: UNT Libraries Government Documents Department

Farm plumbing.

Description: Provides information regarding plumbing materials, pipes, fixtures, installation procedures, and installation costs.
Date: 1940
Creator: Warren, George M. (George Milton)
Partner: UNT Libraries Government Documents Department

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.

Description: This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.
Date: October 1, 2005
Creator: Black, Billy D.; Menicucci, David F. & Harrison, John (Florida Solar Energy Center)
Partner: UNT Libraries Government Documents Department

Plumbing : repairs and utilities

Description: "This manual prescribes materials and methods used to operate, maintain, and repair plumbing systems in Army buildings. Installation details covering alterations and additions to existing facilities are also discussed."
Date: December 1945
Creator: United States. War Department.
Partner: UNT Libraries Government Documents Department

Manufactured Residential Utility Wall System (ResCore),

Description: This paper describes the design and development of a manufactured residential utility wall system referred to as ResCore. ResCore is a self contained, manufactured, residential utility wall that provides complete rough-in of utilities (power, gas, water, and phone) and other functions (exhaust, combustion make-up air, refrigerant lines, etc.) to serve the kitchen, bath, utility, and laundry rooms. Auburn University, Department of Industrial Design faculty, students, supported by a team of graduate student researchers and the project`s advisory team, developed the ResCore. The project was accomplished through a research subcontract from the U.S. Department of Energy administered by the Oak Ridge National Laboratory. The ResCore wall system features a layered manufacturing technique that allows each major component group: structural, cold water, hot water, drain, gas, electric, etc. to be built as a separate subassembly and easily brought together for final assembly. The two structural layers are reinforced with bridging that adds strength and also permits firm attachment of plumbing pipes and other systems to the wall frame.
Date: December 31, 1997
Creator: Wendt, Robert; Lundell, Clark & Lau, Tin Man
Partner: UNT Libraries Government Documents Department

DEFORMATION OF SCORIA CONE BY CONDUIT PRESSURIZATION

Description: A simplified mechanical model is used to simulate the deformation of a scoria cone due to pressurization of magma in a feeder conduit. The scoria cone is modeled as consisting of a cone of stabilized scoria with an axial region of loose scoria (height h{sub 1}), all overlying a vertically oriented cylindrical conduit intruded into rhyolite tuff country rock. For our analyses, the conduit is filled with basalt magma, usually with the upper length (h{sub 2}) solidified. The style of deformation of the cone depends on both h{sub 1} and h{sub 2}. If magma is prevented from hydrofracturing out of the conduit (as, for example, might be the case if the magma is surrounded by a solidified, but plastically deformable layer acting as a gasket backed up by the brittle country rock) pressures in the magma can build to 10s of MPa. When h{sub 1} is 100 m, not unusual for a small isolated basaltic cinder cone, the magma pressure needed to destabilize the cone when molten magma extends all the way to the original ground surface (h{sub 2} = 0) is only about one-third of the pressure when the upper part of the conduit is solidified (h{sub 2} = 25m). In the former case, almost the entire upper third of the cone is at failure in tension when the configuration becomes unstable. In the latter case, small portions of the surface of the cone are failing in tension when instability occurs, but a large volume in the central core of the cone is failing in shear or compressions. These results may provide insight into the status of volcanic plumbing, either past or present, beneath scoria cones. Field observations at the Lathrop Wells volcano in southern Nevada identify structures at the outer edge just below the crater rim that appear ...
Date: August 26, 2005
Creator: Gaffney, E.S.; Damjanac, B.; Krier, D. & Valentine, G.
Partner: UNT Libraries Government Documents Department

90-Ton Triple Cylinder Jack Design

Description: The three D-Zero cryostats (2 EC and 1 CC) will rest on three carriages which in turn ride on a set of hardened ways in the center beam. A pair of Tychoway rollers will be fitted to each of the four corners of the three carriages to provide the rolling support. In the final design, the two EC cryostats will be able to roll out and away from the CC cryostat in order to provide access to the space between each cryostat for maintenance and repairs. The cryostat will be frequently accessed, about once a month. during a collider run. The heaviest cryostat weighs about 360 tons. The large roller weight in one position for such a long period of time, created a concern about the rollers dimpling the hardened ways or even suffering permanent deformations themselves. There is also the possibility that the vertical position of the cryostat will need to be adjusted to align it with the beam line or that the carriage and cryostat will have to be lifted to remove and service the rollers. A device or system was needed to (1) relieve the weight of the cryostats from the rollers and the hardened ways, and (2) minimally adjust the vertical position of the cryostats, if necessary, and/or service the rollers. Compact hydraulic jacks seemed to be the answer. The first and foremost criteria was capacity. It was desired that the jacks be rated to twice the actual load. A jack is to be placed beside each roller, giving a total of eight per cryostat. The load per jack for a 360 ton cryostat would then be 45 tons, leaving 90 tons as the required capacity. The second and equally important criteria to be met was size. After installation of the Tychoway rollers. room to mount ...
Date: September 26, 1988
Creator: Jaques, Al
Partner: UNT Libraries Government Documents Department

[News Script: Lady plumber]

Description: Script from the WBAP-TV/NBC station in Fort Worth, Texas, covering a news story about the first female plumber in Texas that works for the Peerless Plumbing Company in Dallas.
Date: July 20, 1961
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections

1992-1993 Bonneville Appliance Efficiency Program: Showerhead Evaluation Volume II - Appendices

Description: This report included the appendices for 1992-1993 Bonneville appliance efficiency program: showerhead evaluation. It consists of nine appendices, titled: Bonneville documents; overview of research projects; Puget Power and Light persistence study; hot-water flow analyses and assumptions documentation; regional end-use metering program; showerhead and faucet aerator performance assessment; Bonneville showerhead program distribution methods by participating utility; water- and energy-saving measure distribution methods literature review; REMP study load shape results.
Date: January 1, 1995
Creator: Warwick, W.M.
Partner: UNT Libraries Government Documents Department

NORTH PORTAL-HOT WATER CALCULATION-SHOP BUILDING #5006

Description: The purpose of this design analysis and calculation is to determine the demand for domestic cold water and to size the supply main for the Shop Building No.5006 in accordance with the Uniform Plumbing Code (UPC) (Section 4.4.1) and the U.S. Department of Energy, Order 6430.1A-1540 (Section 4.4.2).
Date: January 25, 2006
Creator: Blackstone, R.
Partner: UNT Libraries Government Documents Department

NORTH PORTAL-SANITARY SEWER CALCULATION-SHOP BUILDING #5006

Description: The purpose of this design calculation is to determine the demand on the waste system and to size the sanitary sewer line serving the Shop Building No.5006 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2).
Date: January 24, 1996
Creator: Blackstone, S.
Partner: UNT Libraries Government Documents Department

NORTH PORTAL - DOMESTIC COLD WATER CALCULATION - CHANGE HOUSE FACILITY #5008

Description: The purpose of this design analysis and calculation is to determine the demand for domestic cold water and to size the supply main piping for the Change House Facility No.5008 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2).
Date: March 2, 2000
Creator: Mastilovic, S.
Partner: UNT Libraries Government Documents Department

Grain Refinement of Permanent Mold Cast Copper Base Alloys

Description: Grain refinement is a well established process for many cast and wrought alloys. The mechanical properties of various alloys could be enhanced by reducing the grain size. Refinement is also known to improve casting characteristics such as fluidity and hot tearing. Grain refinement of copper-base alloys is not widely used, especially in sand casting process. However, in permanent mold casting of copper alloys it is now common to use grain refinement to counteract the problem of severe hot tearing which also improves the pressure tightness of plumbing components. The mechanism of grain refinement in copper-base alloys is not well understood. The issues to be studied include the effect of minor alloy additions on the microstructure, their interaction with the grain refiner, effect of cooling rate, and loss of grain refinement (fading). In this investigation, efforts were made to explore and understand grain refinement of copper alloys, especially in permanent mold casting conditions.
Date: April 1, 2005
Creator: M.Sadayappan; J.P.Thomson; M.Elboujdaini; Gu, G.Ping & Sahoo, M.
Partner: UNT Libraries Government Documents Department

Subduction Controls of Hf and Nd Isotopes in Lavas of the Aleutian Island Arc

Description: The Hf and Nd isotopic compositions of 71 Quaternary lavas collected from locations along the full length of the Aleutian island arc are used to constrain the sources of Aleutian magmas and to provide insight into the geochemical behavior of Nd and Hf and related elements in the Aleutian subduction-magmatic system. Isotopic compositions of Aleutian lavas fall approximately at the center of, and form a trend parallel to, the terrestrial Hf-Nd isotopic array with {var_epsilon}{sub Hf} of +12.0 to +15.5 and {var_epsilon}{sub Nd} of +6.5 to +10.5. Basalts, andesites, and dacites within volcanic centers or in nearby volcanoes generally all have similar isotopic compositions, indicating that there is little measurable effect of crustal or other lithospheric assimilation within the volcanic plumbing systems of Aleutian volcanoes. Hafnium isotopic compositions have a clear pattern of along-arc increase that is continuous from the eastern-most locations near Cold Bay to Piip Seamount in the western-most part of the arc. This pattern is interpreted to reflect a westward decrease in the subducted sediment component present in Aleutian lavas, reflecting progressively lower rates of subduction westward as well as decreasing availability of trench sediment. Binary bulk mixing models (sediment + peridotite) demonstrate that 1-2% of the Hf in Aleutian lavas is derived from subducted sediment, indicating that Hf is mobilized out of the subducted sediment with an efficiency that is similar to that of Sr, Pb and Nd. Low published solubility for Hf and Nd in aqueous subduction fluids lead us to conclude that these elements are mobilized out of the subducted component and transferred to the mantle wedge as bulk sediment or as a silicate melt. Neodymium isotopes also generally increase from east to west, but the pattern is absent in the eastern third of the arc, where the sediment flux is high and increases ...
Date: August 29, 2010
Creator: Yogodzinski, Gene; Vervoort, Jeffery; Brown, Shaun Tyler & Gerseny, Megan
Partner: UNT Libraries Government Documents Department