13 Matching Results

Search Results

Advanced search parameters have been applied.

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-12-488, MCU-12-489, MCU-12-490, MCU-12-491, MCU-12-492 AND MCU-12-493: QUARTERLY SAMPLE FROM OCTOBER 2012

Description: Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-12-488, MCU-12-489, MCU-12-490, MCU-12-491, MCU-12-492 and MCU-12-493 received 24 October 2012 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is within tolerance but is trending upward compared to the {sup 137}Cs measurement made last year.
Date: January 16, 2013
Creator: Fondeur, F. F.; Peters, T. B. & Fink, S. D.
Partner: UNT Libraries Government Documents Department

Solvent hold tank sample results for MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 AND MCU-13-148: quarterly sample from January 2013

Description: Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 and MCU-13-148 received 29 January 2012 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2012.
Date: March 27, 2013
Creator: Fondeur, F. F. & Peters, T. B.
Partner: UNT Libraries Government Documents Department

Solvent Hold Tank Sample Results For MCU-13-814, MCU-13-815, MCU-13-816, MCU-13,817, MCU-13-818 And MCU-13-819: Quarterly Sample From May 2013

Description: Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-814, MCU-13-815, MCU-13-816, MCU-13-817, MCU-13-818 and MCU-13-819 received May 28, 2013 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine despite of the 272 g of TOA that was added to the solvent on June 5, 2013 based on the solvent containing a TOA level of 45% of nominal. A new TOA analysis method (HCl titration) has been used and its output was statistically similar to the results from the SVOA-TOA method. This method provides an independent method for measuring TOA and TiDG in MCU-NG solvent. An impurity containing a tert-butyl group was detected in the solvent and further analytical analysis is needed to identify it. SRNL recommends determining the impact of this impurity on the mass transfer ability of the solvent. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is above the results observed from the January 2013.
Date: August 13, 2013
Creator: Fondeur, F. F. & Taylor-Pashow, K. M.
Partner: UNT Libraries Government Documents Department

Results of Analysis of Macrobatch 3 Decontaminated Salt Solution Coalescer from May 2010

Description: SRNL analyzed the Decontamination Salt Solution (DSS) coalescer from MCU by several analytical methods. This unit was removed from service in May 2010. The results of these analyses indicate that there is very little evidence of fouling via excessive solids, either from the leaching studies or X-Ray Diffraction (XRD) analysis.
Date: December 18, 2012
Creator: Peters, T. B. & Fink, S. D.
Partner: UNT Libraries Government Documents Department

Results Of Routine Strip Effluent Hold Tank And Decontaminated Salt Solution Hold Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 5 Operations

Description: Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the ''microbatches'' of Integrated Salt Disposition Project (ISDP) Salt Batch (''Macrobatch'') 5 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and the previous set of results for Macrobatch 4 samples indicate generally consistent operations. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in the Actinide Removal process (ARP).
Date: April 30, 2013
Creator: Peters, T. B. & Fondeur, F. F.
Partner: UNT Libraries Government Documents Department

Sample results from the integrated salt disposition program macrobatch 6 tank 21H qualifications MST solids sample

Description: Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 6 processing. As part of this qualification work, SRNL performed an Actinide Removal Process (ARP) test. From this test, the residual monosodium titanate (MST) was analyzed for radionuclide uptake. The results of these analyses are reported and are within historical precedent.
Date: February 26, 2013
Creator: Peters, T. B.
Partner: UNT Libraries Government Documents Department

Sample Results From The Interim Salt Disposition Program Macrobatch 6 Tank 21H Qualification Samples

Description: Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 6 for the Interim Salt Disposition Project (ISDP). This document reports partial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 6 strategy are identified.
Date: December 20, 2012
Creator: Peters, T. B. & Fink, S. D.
Partner: UNT Libraries Government Documents Department

Sample Results from the Interim Salt Disposition Program Macrobatch 6 Tank 21H Qualification Samples

Description: Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 6 for the Interim Salt Disposition Project (ISDP). This document reports partial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 6 strategy are identified.
Date: December 11, 2012
Creator: Peters, T. B. & Fink, S. D.
Partner: UNT Libraries Government Documents Department

Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification Samples

Description: Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 7 for the Interim Salt Disposition Program (ISDP). An ARP and several ESS tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP/MCU. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. A demonstration of the monosodium titanate (0.2 g/L) removal of strontium and actinides provided acceptable 4 hour average decontamination factors for Pu and Sr of 3.22 and 18.4, respectively. The Four ESS tests also showed acceptable behavior with distribution ratios (D(Cs)) values of 15.96, 57.1, 58.6, and 65.6 for the MCU, cold blend, hot blend, and Next Generation Solvent (NGS), respectively. The predicted value for the MCU solvent was 13.2. Currently, there are no models that would allow a prediction of extraction behavior for the other three solvents. SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed. While no outstanding issues were noted, the presence of solids in the samples should be investigated in future work. It is possible that the solids may represent a potential reservoir of material (such as potassium) that could have an impact on MCU performance if they were to dissolve back into the feed solution. This salt batch is intended to be the first batch to be processed through MCU entirely using the new NGS-MCU solvent.
Date: August 8, 2013
Creator: Peters, T. B. & Washington, A. L. II
Partner: UNT Libraries Government Documents Department

Interim salt disposition program macrobatch 6 tank 21H qualification monosodium titanate and cesium mass transfer tests

Description: Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Interim Salt Disposition Program (ISDP) Batch 6 processing. This qualification material was a set of six samples from Tank 21H in October 2012. This sample was used as a real waste demonstration of the Actinide Removal Process (ARP) and the Extraction-Scrub-Strip (ESS) tests process. The Tank 21H sample was contacted with a reduced amount (0.2 g/L) of MST and characterized for strontium and actinide removal at 0 and 8 hour time intervals in this salt batch. {sup 237}Np and {sup 243}Am were both observed to be below detection limits in the source material, and so these results are not reported in this report. The plutonium and uranium samples had decontamination factor (DF) values that were on par or slightly better than we expected from Batch 5. The strontium DF values are slightly lower than expected but still in an acceptable range. The Extraction, Scrub, and Strip (ESS) testing demonstrated cesium removal, stripping and scrubbing within the acceptable range. Overall, the testing indicated that cesium removal is comparable to prior batches at MCU.
Date: February 25, 2013
Creator: Washington, A. L. II; Peters, T. B. & Fink, S. D.
Partner: UNT Libraries Government Documents Department

Results Of Initial Analyses Of The Macrobatch 7 Tank 21H Qualification Samples

Description: Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt (Macro) Batch 7 for the Interim Salt Disposition Program (ISDP) through ARP/MCU. This document reports the initial results of the analyses of samples of Tank 21H. Further results on the chemistry and other tests will be issued in the future. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. Based upon a SRNL settling test, the solids should settle well within the months-long settling period to be employed in Tank 21H. However, SRNL recommends analyzing the solids to provide input to OLI modeling in order to evaluate the impacts of these solids to present and future salt batches.
Date: July 8, 2013
Creator: Peters, T. B. & Washington, A. L. II
Partner: UNT Libraries Government Documents Department

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-1403/1404/1405/1406/1407/1408: QUARTERLY SAMPLE FROM SEPTEMBER 2013

Description: Savannah River National Laboratory (SRNL) analyzed solvent samples from the Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-1403, MCU-13-1404, MCU-13-1405, MCU-13-1406, MCU-13-1407, and MCU-13-1408 received on September 17, 2013 are reported. This sample was taken after the addition of the Next Generation Solvent (NGS) cocktail to produce a NGS-MCU blended solvent. The results show that the solvent contains a slight excess of Isopar� L and a deficit concentration of modifier and TiDG when compared to the target composition. Addition of TiDG trim is recommended. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is within tolerance and that the value has returned to levels observed in 2011. In contrast to what was observed in the heel prior to adding the NGS cocktail, no organic impurities were detected in these solvent samples.
Date: November 20, 2013
Creator: Fondeur, F. & Taylor-Pashow, K.
Partner: UNT Libraries Government Documents Department

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-189, MCU-13-190, AND MCU-13-191: QUARTERLY SAMPLE FROM SEPTEMBER 2013

Description: Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-189, MCU-13-190, and MCU-13-191 received on September 4, 2013 are reported. The results show that the solvent (remaining heel in the SHT tank) at MCU contains excess Isopar� L and a deficit concentration of modifier and trioctylamine when compared to the standard MCU solvent. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar� L trimming at this time. Since MCU is switching to NGS, there is no need to add TOA nor modifier. SRNL also analyzed the SHT sample for {{sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2011.
Date: October 31, 2013
Creator: Fondeur, F. & Taylor-Pashow, K.