open access

Review of state-of-the-art of solar collector corrosion processes. Task 1 of solar collector studies for solar heating and cooling applications. Final technical progress report

Description: The state-of-the-art of solar collector corrosion processes is reviewed, and Task 1 of a current research program on use of aqueous heat transfer fluids for solar heating and cooling is summarized. The review of available published literature has indicated that lack of quantitative information exists relative to collector corrosion at the present time, particularly for the higher temperature applications of solar heating and cooling compared to domestic water heating. Solar collector systems ar… more
Date: April 11, 1980
Creator: Clifford, J E & Diegle, R B
Partner: UNT Libraries Government Documents Department
open access

Solar hot water demonstration project at Red Star Industrial Laundry, Fresno, California

Description: The Final Report of the Solar Hot Water System located at the Red Star Industrial Laundry, 3333 Sabre Avenue, Fresno, California, is presented. The system was designed as an integrated wastewater heat recovery and solar preheating system to supply a part of the hot water requirements. It was estimated that the natural gas demand for hot water heating could be reduced by 56 percent (44 percent heat reclamation and 12 percent solar). The system consists of a 16,500 gallon tube-and-shell wastewate… more
Date: July 1, 1980
Partner: UNT Libraries Government Documents Department
open access

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

Description: The solar energy hot water system installed in the Days Inns of America, Inc., Days Inn Motel (120 rooms) I-95 and Cagle Road, Jacksonville, Florida, is described. The solar system was designed by ILI, Incorporated to provide 65 percent of the hot water demand. The system is one of eleven systems planned under this grant. Water (in the Solar Energy Products, Model CU-30ww liquid flat plate collector (900 square feet) system) automatically drains into the 1000 gallon lined and vented steel stora… more
Date: September 1, 1980
Partner: UNT Libraries Government Documents Department
open access

Thermal energy storage for power generation

Description: Studies strongly indicate that the United States will face widespread electrical power constraints in the 1990s, with most regions of the country experiencing capacity shortages by the year 2000. In many cases, the demand for increased power will occur during intermediate and peak demand periods. Much of this demand is expected to be met by oil- and natural gas-fired Brayton cycle turbines and combined-cycle plants. While natural gas is currently plentiful and reasonably priced, the availabilit… more
Date: October 1, 1989
Creator: Drost, M. K.; Antoniak, Z. I.; Brown, D. R. & Sathyanarayana, K.
Partner: UNT Libraries Government Documents Department
open access

Coal Technology Program. Progress report for November 1977

Description: A block of Pittsburgh seam bituminous coal and a block of Wyodak subbituminous coal were pyrolyzed under reducing gas in support of in situ gasification. Information from previously completed block pyrolysis of bituminous coal under an argon atmosphere show that differences in evolved gas result from differences in heating rates. Compared to block pyrolysis at 0.3 C/sup 0//min, block pyrolysis at 3 C/sup 0//min produces less gas but gas with a higher heating value, yielding a higher overall pyr… more
Date: January 1, 1978
Partner: UNT Libraries Government Documents Department
open access

OTEC-1 Power System Test Program: test plan for first deployment

Description: This report describes in detail all tests planned for the first eight-month deployment of OTEC-1, a test facility constructed by the US Department of Energy in order to test heat exchangers for closed-cycle power plants using ocean thermal energy. Tests to be performed during the first-deployment period are aimed primarily at determining (1) the effectiveness of countermeasures in preventing biofouling of the heat exchanters, (2) the extent of environmental impacts associated with operation of … more
Date: March 1, 1980
Partner: UNT Libraries Government Documents Department
open access

Prevention of biofouling on heat transfer surfaces of ocean thermal energy converters. Progress report, May 1, 1975--November 30, 1975

Description: The objectives of the program were to develop chemical processes utilizing a combination of certain fluorochemicals and tribulyltin based toxicants for treating the surfaces of metals which may be used to fabricate OTEC heat exchangers, and to demonstrate the effectiveness of these surface treatments as antibiofoulants. Aluminium alloy No. 3003-H14 and titanium were testd, neither of which proved satisfactory. (WDM)
Date: December 1, 1975
Creator: Ostrozynski, R.L. & Jones, P.E.
Partner: UNT Libraries Government Documents Department
open access

Coarse-node computations with an adaptive node structure

Description: The analysis with COMMIX of liquid metal reactor (LMR) intermediate heat exchanger (IHX) transients that are characterized by low flows, and especially imbalanced low flows, shows that if a coarse-node structure is used the predicted temperatures are significantly different than those given by a fine-node structure. If a fine-node structure is used, for problems that involve a large part of the plant, the computation time becomes excessive. This paper presents an improved version of an adaptive… more
Date: January 1, 1988
Creator: Tzanos, C.P.
Partner: UNT Libraries Government Documents Department
open access

Stirling total energy systems study. Final report, May 15, 1976--June 13, 1977

Description: The application of Stirling cycle prime movers to total energy power generation systems was investigated. Electrical, heating, and cooling demand profiles for a typical residential complex, hospital, and office building were studied, and alternative Stirling total energy systems were conceptualized for each site. These were analyzed in detail and contrasted with purchased-power systems for these sites to determine fuel-energy savings and investment attractiveness. The residential complex and ho… more
Date: August 1, 1977
Creator: Lehrfeld, D.
Partner: UNT Libraries Government Documents Department
open access

Economic impact of using nonmetallic materials in low to intermediate temperature geothermal well construction. Volume 1

Description: The results are presented of an exhaustive literature search and evaluation concerning the properties and economics of commercially available nonmetallic well casing and screens. These materials were studied in terms of their use in low to intermediate temperature geothermal well construction.
Date: December 1, 1979
Partner: UNT Libraries Government Documents Department
open access

Thin polymer icemaker development and test program

Description: We have constructed and tested a small device to produce ice in ice/water mixtures using a cold fluid as the heat sink. The device is a flexible heat exchanger constructed from a thin film of a suitable polymer. When filled with circulating liquid coolant the heat exchanger consists of an inflated series of parallel tubes; ice forms on the outside in complementary half cylinders. When the circulation is cut off, gravity drains the coolant and the static head of the water bath crushes the tubes,… more
Date: August 1, 1991
Creator: Leigh, R.W. (Pratt Inst., Brooklyn, NY (United States))
Partner: UNT Libraries Government Documents Department
open access

Improved ceramic heat exchanger material

Description: Various ceramic materials in the form of small, monolithic bars were screened as candidate materials in heat exchanger structures for automotive gas turbine engines. The material finally selected consists of 60 w/o* petalite (LAS) and 40 w/o of a recrystallizable glass which converts during thermal processing to cordierite (MAS). This new material, GE-3200, was fabricated by Coors Porcelain Company into a circular honeycomb structure 53.3 cm diameter and 10.2 cm thick (21'' x 4'') and having 69… more
Date: November 1, 1977
Creator: Rauch, H. W., Sr.
Partner: UNT Libraries Government Documents Department
open access

Application of direct contact heat exchangers to geothermal power production cycles. Project review, December 1, 1974--May 31, 1977

Description: Work performed on the development of direct contact heat exchanger power cycles for geothermal applications is reviewed. The period covered in the report is from the inception of the project in 1974 through May 31, 1977. Results from a large experimental program on heat exchanger develpment as well as from many analyses of components and cycle performance and economics are given. A number of working fluids and operating conditions have been considered, and no major obstacles for the implementat… more
Date: January 1, 1977
Creator: Jacobs, H. R.; Boehm, R. F. & Hansen, A. C.
Partner: UNT Libraries Government Documents Department
open access

Advanced materials for geothermal energy processes

Description: The primary goal of the geothermal materials program is to ensure that the private sector development of geothermal energy resources is not constrained by the availability of technologically and economically viable materials of construction. This requires the performance of long-term high risk GHTD-sponsored materials R and D. Ongoing programs described include high temperature elastomers for dynamic sealing applications, advanced materials for lost circulation control, waste utilization and di… more
Date: August 1, 1985
Creator: Kukacka, L. E.
Partner: UNT Libraries Government Documents Department
open access

High temperature recuperator tests. Final report

Description: A demonstration and test program was conducted on a high temperature, two pass ceramic tube recuperator. Data pertaining to heat exchanger performance characteristics were collected and compared with calculated values. The effect of improved heat exchanger effectiveness on system fuel consumption was demonstrated. Changes in fuel flow as a function of combustion air preheat while maintaining a given heat load were demonstrated. The effects of excess air on fuel consumption with and without syst… more
Date: May 1, 1980
Creator: Bjerklie, J. W. & Penty, R. A.
Partner: UNT Libraries Government Documents Department
open access

Kilowatt isotope power system. Component test procedure for the ground demonstration system radiator bypass valve

Description: This test procedure provides a detailed description of the verification methods which shall be used in the developmental program to be conducted on the Kilowatt Isotope Power System (KIPS) Radiator Bypass Valve, to fulfill the requirements of the Ground Demonstration System Design Criteria. The test objective is to demonstrate the bypass flow characteristics of the valve as a function of the Jet Condensor Inlet Temperature. To accomplish the test objective the pump discharge temperature (TPO) w… more
Date: April 1, 1977
Partner: UNT Libraries Government Documents Department
open access

Impacts of the national energy programme on solar economics

Description: The National Energy Plan (NEP) sets as a goal the use of solar energy in two and a half million homes in 1985. A key provision of the NEP (as well as congressional alternatives) provides for the subsidization of solar equipment. The extent to which these subsidies (income tax credits) might offset the impact of continued energy-price control is examined. Regional prices and availability of conventional energy sources (oil, gas, and electricity) were compiled to obtain a current and consistent s… more
Date: January 1, 1978
Creator: Ben-David, S.; Noll, S.; Roach, F. & Schulze, W.
Partner: UNT Libraries Government Documents Department
open access

Initial results from the first Los Alamos hot dry rock energy system

Description: The pressurized-water loop for extraction of natural heat from dry crustal rock is, as this is written, eight weeks into its initial long-term continuous circulation test. During most of this time, flow-impedance through the man-made fracture system has decreased continuously so that, with a nearly constant pressure difference between injection and recovery wells, flow rate has increased steadily to the maximum capacity of the surface piping--about 16 liters per second. Temperature of water ent… more
Date: January 1, 1978
Creator: Smith, M.C.
Partner: UNT Libraries Government Documents Department
open access

Critical Technology List update. Final technical report

Description: ICRC has reviewed and updated its List of critical technology. The List comprises all proposed SRC-I Demonstration Plant equipment whose use has been determined to involve some degree of potential safety, performance, or environmental risk. ICRC has subjected equipment on the Critical Technology c to special technical review to ensure the highest possible level of quality and lowest cost commensurate with acceptable overall risks. Equipment or equipment systems still considered to be high risk … more
Date: March 1, 1983
Partner: UNT Libraries Government Documents Department
open access

Literature review of the saturation state of seawater with respect to calcium carbonate and its possible significance for scale formation on OTEC heat exchangers

Description: An investigation of available data on the saturation state of seawater with respect to calcium carbonate and its possible significance for scale formation on Ocean Thermal Energy Conversion (OTEC) heat exchangers has been carried out. Pertinent oceanographic data is lacking at or near potential OTEC sites for the calculation of the degree of saturation of seawater with respect to calcium carbonate. Consequently, only ''extrapolated'' saturation values can be used. These indicate that near surfa… more
Date: April 5, 1978
Creator: Morse, J. W.; de Kanel, J. & Craig, Jr., H. L.
Partner: UNT Libraries Government Documents Department
open access

The dry heat exchanger calorimeter system

Description: A radiometric isothermal heat flow calorimeter and preconditioner system that uses air instead of water as the heat exchange medium has been developed at Mound. The dry heat exchanger calorimeter is 42 inches high by 18 inches in diameter and the preconditioner is a 22 inch cube, making it extremely compact compared to existing units. The new system is ideally suited for transportable, stand-alone, or glovebox applications. Preliminary tests of the system have produced sample measurements with … more
Date: January 1, 1991
Creator: Renz, D. P.; Wetzel, J. R.; James, S. J.; Kasperski, P. W. & Duff, M. F.
Partner: UNT Libraries Government Documents Department