96 Matching Results

Search Results

Advanced search parameters have been applied.

Monitoring and Commissioning Verification Algorithms for CHP Systems

Description: This document provides the algorithms for CHP system performance monitoring and commissioning verification (CxV). It starts by presenting system-level and component-level performance metrics, followed by descriptions of algorithms for performance monitoring and commissioning verification, using the metric presented earlier. Verification of commissioning is accomplished essentially by comparing actual measured performance to benchmarks for performance provided by the system integrator and/or component manufacturers. The results of these comparisons are then automatically interpreted to provide conclusions regarding whether the CHP system and its components have been properly commissioned and where problems are found, guidance is provided for corrections. A discussion of uncertainty handling is then provided, which is followed by a description of how simulations models can be used to generate data for testing the algorithms. A model is described for simulating a CHP system consisting of a micro-turbine, an exhaust-gas heat recovery unit that produces hot water, a absorption chiller and a cooling tower. The process for using this model for generating data for testing the algorithms for a selected set of faults is described. The next section applies the algorithms developed to CHP laboratory and field data to illustrate their use. The report then concludes with a discussion of the need for laboratory testing of the algorithms on a physical CHP systems and identification of the recommended next steps.
Date: March 31, 2008
Creator: Brambley, Michael R.; Katipamula, Srinivas & Jiang, Wei
Partner: UNT Libraries Government Documents Department

Heat loss from an open cavity

Description: Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating temperature, and receiver angle is presented. The resulting data is a source to evaluate the STEP measurements.
Date: December 1, 1995
Creator: McDonald, C.G.
Partner: UNT Libraries Government Documents Department

District cooling and heating development in Stamford, CT. Final report

Description: This report summarizes the development options for introducing district cooling and heating in downtown Stamford, Connecticut. A district energy system as defined for the Stamford project is the production of chilled and hot water at a central energy plant, and its distribution underground to participating building in the vicinity. The objective of the study was to investigate implementation of a district energy system in conjunction with cogeneration as a means to encourage energy conservation and provide the city with an economic development tool. Analysis of the system configuration focused on selecting an arrangement which offered a realistic opportunity for implementation. Three main alternatives were investigated: (1) construction of an 82 MW cogeneration plant and a district heating and cooling system to serve downtown buildings, (2) construction of a small (4 MW) in-fence cogeneration plant combined with cooling and heating, and (3) construction of a district cooling and heating plant to supply selected buildings. Option (1) was determined to be unfeasible at this time due to low electricity prices. The analysis demonstrated that alternatives (2) and (3) were feasible. A number of recommendations are made for detailed cost estimates and ownership, leasing, and financial issues. 12 figs., 10 tabs.
Date: December 1, 1994
Partner: UNT Libraries Government Documents Department

CHP REGIONAL APPLICATION CENTERS: A PRELIMINARY INVENTORY OF ACTIVITIES AND SELECTED RESULTS

Description: Eight Regional CHP Application Centers (RACs) are funded by the U.S. Department of Energy (DOE) to facilitate the development and deployment of Combined Heat and Power (CHP) technologies in all 50 states. The RACs build end-user awareness by providing CHP-related information to targeted markets through education and outreach; they work with the states and regulators to encourage the creation and adoption of favorable public policies; and they provide CHP users and prospective users with technical assistance and support on specific projects. The RACs were started by DOE as a pilot program in 2001 to support the National CHP Roadmap developed by industry to accelerate deployment of energy efficient CHP technologies (U.S. Combined Heat and Power Association 2001). The intent was to foster a regional presence to build market awareness, address policy issues, and facilitate project development. Oak Ridge National Laboratory (ORNL) has supported DOE with the RAC program since its inception. In 2007, ORNL led a cooperative effort involving DOE and some CHP industry stakeholders to establish quantitative metrics for measuring the RACs accomplishments. This effort incorporated the use of logic models to define and describe key RAC activities, outputs, and outcomes. Based on this detailed examination of RAC operations, potential metrics were identified associated with the various key sectors addressed by the RACs: policy makers; regulatory agencies; investor owned utilities; municipal and cooperative utilities; financiers; developers; and end users. The final product was reviewed by a panel of representatives from DOE, ORNL, RACs, and the private sector. The metrics developed through this effort focus on major RAC activities as well as on CHP installations and related outcomes. All eight RACs were contacted in August 2008 and asked to provide data for every year of Center operations for those metrics on which they kept records. In addition, data on CHP ...
Date: October 1, 2009
Creator: Schweitzer, Martin
Partner: UNT Libraries Government Documents Department

Specification of Selected Performance Monitoring and Commissioning Verification Algorithms for CHP Systems

Description: Pacific Northwest National Laboratory (PNNL) is assisting the U.S. Department of Energy (DOE) Distributed Energy (DE) Program by developing advanced control algorithms that would lead to development of tools to enhance performance and reliability, and reduce emissions of distributed energy technologies, including combined heat and power technologies. This report documents phase 2 of the program, providing a detailed functional specification for algorithms for performance monitoring and commissioning verification, scheduled for development in FY 2006. The report identifies the systems for which algorithms will be developed, the specific functions of each algorithm, metrics which the algorithms will output, and inputs required by each algorithm.
Date: October 6, 2006
Creator: Brambley, Michael R. & Katipamula, Srinivas
Partner: UNT Libraries Government Documents Department

THERMODYNAMICS OF PARTIALLY FROZEN COOLING LAKES

Description: The Rochester Institute of Technology (RIT) collected visible, SWIR, MWIR and LWIR imagery of the Midland (Michigan) Cogeneration Ventures Plant from aircraft during the winter of 2008-2009. RIT also made ground-based measurements of lake water and ice temperatures, ice thickness and atmospheric variables. The Savannah River National Laboratory (SRNL) used the data collected by RIT and a 3-D hydrodynamic code to simulate the Midland cooling lake. The hydrodynamic code was able to reproduce the time distribution of ice coverage on the lake during the entire winter. The simulations and data show that the amount of ice coverage is almost linearly proportional to the rate at which heat is injected into the lake (Q). Very rapid melting of ice occurs when strong winds accelerate the movement of warm water underneath the ice. A snow layer on top of the ice acts as an insulator and decreases the rate of heat loss from the water below the ice to the atmosphere above. The simulated ice cover on the lake was not highly sensitive to the thickness of the snow layer. The simplicity of the relationship between ice cover and Q and the weak responses of ice cover to snow depth over the ice are probably attributable to the negative feedback loop that exists between ice cover and heat loss to the atmosphere.
Date: January 5, 2010
Creator: Garrett, A.; Casterline, M. & Salvaggio, C.
Partner: UNT Libraries Government Documents Department

Coal Air Turbine ``CAT`` program invention 604. Eighth quarter project report and final for the project, August--September 1996

Description: The primary objective of this ``CAT`` project is to complete a conceptual design of this unique new combination of existing technology with cost estimates to show that the ``CAT`` system offers the economic incentive with low technical risk for a plant to be built which will demonstrate its viability. The technologies involved in the components of a ``CAT`` plant are proven, and the integration of the components into a complete plant is the only new developmental activity involved. Industry and the Federal General Services Administration (GSA), require the demonstration of a ``commercial plant`` before the viability of a new concept is accepted. To satisfy this requirement the construction of a plant of commercially viable size in excess of 15 MW if cogeneration and above 30 MW if all power, is proposed. This plant will produce economical power and heat for the owner. The plant will operate for a full commercial life and continue as an operating demonstration of the viability of the technology, gathering long term life and maintenance data, all adding to the credibility of the concept.
Date: September 30, 1996
Creator: Foster-Pegg, R.W.
Partner: UNT Libraries Government Documents Department

Thermoacoustic co-generation unit. Final report

Description: The combination of a thermoacoustic engine with a STAR alternator promises to comprise a simple, reliable combustion-powered electric generator. In this CRADA, the authors married these two technologies for the first time, to learn what technical issues arise in the combination. The results are encouraging, but the work is not yet complete.
Date: December 9, 1997
Creator: Swift, G.W. & Corey, J.
Partner: UNT Libraries Government Documents Department

Effects of a shortened depreciation schedule on the investment costs for combined heat and power

Description: We investigate and compare several generic depreciation methods to assess the effectiveness of possible policy measures with respect to the depreciation schedules for investments in combined heat and power plants in the United States. We assess the different depreciation methods for CHP projects of various sizes (ranging from 1 MW to 100 MW). We evaluate the impact of different depreciation schedules on the tax shield, and the resulting tax savings to potential investors. We show that a shorter depreciation cycle could have a substantial impact on the cost of producing power, making cogeneration more attractive. The savings amount to approximately 6-7 percent of capital and fixed operation and maintenance costs, when changing from the current system to a 7 year depreciation scheme with switchover from declining balance to straight line depreciation. Suggestions for further research to improve the analysis are given.
Date: November 15, 2001
Creator: Kranz, Nicole & Worrell, Ernst
Partner: UNT Libraries Government Documents Department

American Recovery and Reinvestment Act, Federal Energy Management Program, Technical Assistance Project 228 - US Army Installation Management Command - Pacific Region, Honolulu, Hawaii

Description: This report documents the activities of a resource efficiency manager that served the US Army Installation Management Command - Pacific Region during the period November 23, 2009 and August 31, 2010.
Date: September 30, 2010
Creator: Arends, J. & Sandusky, William F.
Partner: UNT Libraries Government Documents Department

Opportunities for Combined Heat and Power in Data Centers

Description: Data centers represent a rapidly growing and very energy intensive activity in commercial, educational, and government facilities. In the last five years the growth of this sector was the electric power equivalent to seven new coal-fired power plants. Data centers consume 1.5% of the total power in the U.S. Growth over the next five to ten years is expected to require a similar increase in power generation. This energy consumption is concentrated in buildings that are 10-40 times more energy intensive than a typical office building. The sheer size of the market, the concentrated energy consumption per facility, and the tendency of facilities to cluster in 'high-tech' centers all contribute to a potential power infrastructure crisis for the industry. Meeting the energy needs of data centers is a moving target. Computing power is advancing rapidly, which reduces the energy requirements for data centers. A lot of work is going into improving the computing power of servers and other processing equipment. However, this increase in computing power is increasing the power densities of this equipment. While fewer pieces of equipment may be needed to meet a given data processing load, the energy density of a facility designed to house this higher efficiency equipment will be as high as or higher than it is today. In other words, while the data center of the future may have the IT power of ten data centers of today, it is also going to have higher power requirements and higher power densities. This report analyzes the opportunities for CHP technologies to assist primary power in making the data center more cost-effective and energy efficient. Broader application of CHP will lower the demand for electricity from central stations and reduce the pressure on electric transmission and distribution infrastructure. This report is organized into the following sections: ...
Date: March 1, 2009
Creator: Darrow, Ken & Hedman, Bruce
Partner: UNT Libraries Government Documents Department

National Account Energy Alliance Final Report for the Ritz Carlton, San Francisco Combined Heat and Power Project

Description: Under collaboration between DOE and the Gas Technology Institute (GTI), UTC Power partnered with Host Hotels and Resorts to install and operate a PureComfort 240M Cooling, Heating and Power (CHP) System at the Ritz-Carlton, San Francisco. This packaged CHP system integrated four microturbines, a double-effect absorption chiller, two fuel gas boosters, and the control hardware and software to ensure that the system operated predictably, reliably, and safely. The chiller, directly energized by the recycled hot exhaust from the microturbines, could be configured to provide either chilled or hot water. As installed, the system was capable of providing up to 227 kW of net electrical power and 142 RT of chilled water at a 59F ambient temperature.
Date: November 1, 2007
Creator: Rosfjord, Thomas J.
Partner: UNT Libraries Government Documents Department

CHP REGIONAL APPLICATION CENTERS: ACTIVITIES AND SELECTED RESULTS

Description: Between 2001 and 2005, the U.S. Department of Energy (DOE) created a set of eight Regional Application Centers (RACs) to facilitate the development and deployment of Combined Heat and Power (CHP) technologies. By utilizing the thermal energy that is normally wasted when electricity is produced at central generating stations, Combined Heat and Power installations can save substantial amounts of energy compared to more traditional technologies. In addition, the location of CHP facilities at or near the point of consumption greatly reduces or eliminates electric transmission and distribution losses. The regional nature of the RACs allows each one to design and provide services that are most relevant to the specific economic and market conditions in its particular geographic area. Between them, the eight RACs provide services to all 50 states and the District of Columbia. Through the end of the federal 2009 fiscal year (FY 2009), the primary focus of the RACs was on providing CHP-related information to targeted markets, encouraging the creation and adoption of public policies and incentives favorable to CHP, and providing CHP users and prospective users with technical assistance and support on specific projects. Beginning with the 2010 fiscal year, the focus of the regional centers broadened to include district energy and waste heat recovery and these entities became formally known as Clean Energy Application Centers, as required by the Energy Independence and Security Act (EISA) of 2007. In 2007, ORNL led a cooperative effort to establish metrics to quantify the RACs accomplishments. That effort began with the development of a detailed logic model describing RAC operations and outcomes, which provided a basis for identifying important activities and accomplishments to track. A data collection spreadsheet soliciting information on those activities for FY 2008 and all previous years of RAC operations was developed and sent to the RACs ...
Date: August 1, 2010
Creator: Schweitzer, Martin
Partner: UNT Libraries Government Documents Department

Efficiency and supply resource options for the upgrade of the Plzen district heating system

Description: We examined options for meeting the district heating system steam and hot water heating loads associated with the Plzefi Central Heating Plant, two interconnected boilers serving the Kosutka and Bory regions, and the distributed systems in the Letna/Doubravka and Svetovar regions. The assessment applied integrated resource planning to combine the separate supply and demand-side assessments conducted for the system. Four system load scenarios were examined-high and low growth with and without programmatic efficiency. Hot water loads ranged from the current level of 277 megawatts thermal (MW{sub t}) to 320 MW{sub t} in a high growth scenario without efficiency to 253 MW{sub t} in a low growth scenario with programmatic efficiency. The high growth scenario includes an addition of approximately 50 MW{sub t} load from the connection of distributed boilers. An additional 250 MW{sub t} load served by distributed boilers may provide additional potential for system expansion. Steam loads are projected to increase from 93 MW{sub t} to 100 MW{sub t} in the high growth scenario and. decrease to 89 MW{sub t}, in the low growth scenario. Two system expansion cases were considered. The moderate system expansion provided for the Heat Line East I connection to serve the Letna/Doubravka region and the fall system expansion case further provided for the Heat Line East II connection to serve the Svetovar region. In the moderate case, the life of the Svetovar plant is extended to continue as a stand-alone system. Four central plant supply configurations providing for additional cogeneration capacity were applied to the load scenarios: 1. Life extension to existing facilities with a new coal-fired cogeneration unit in 2003, 2. Retirement of some existing units and a new coal-fired cogeneration unit in 1997, 3. Retirement of some existing units and a new gas- fired cogeneration unit in 1997, 4. Gas: Retirement of ...
Date: June 1, 1996
Partner: UNT Libraries Government Documents Department

ADVANCED GASIFICATION-BASED FUEL CONVERSION AND ELECTRIC ENERGY PRODUCTION SYSTEM

Description: Boise Cascade Corporation and the Gas Technology Institute (GTI) are cooperating to develop, demonstrate and place in continuous operation an advanced biomass gasification-based power generation system suitable for near-term commercial deployment in the Forest Products Industry. The system will be used in conjunction with, rather than in place of, existing wood waste fired boilers and flue gas cleanup systems. The novel system will include three advanced technological components based on GTI's RENUGAS{reg_sign} and METHANE de-NOX{reg_sign} technologies, and a gas turbine-based power generation concept developed in DOE's High Performance Power System (HIPPS) program. The system has, as its objective, to avoid the major hurdles of high-pressure gasification, i.e., high-pressure fuel feeding and ash removal, and hot gas cleaning that are typical for conventional IGCC power generation. It aims to also minimize capital intensity and technology risks. The system is intended to meet the immediate needs of the forest products industry for highly efficient and environmentally friendly electricity and steam generation systems utilizing existing wood waste as fuel resources.
Date: January 1, 2002
Creator: Rabovitser, Joseph & Bryan, Bruce
Partner: UNT Libraries Government Documents Department

Small-scale AFBC hot air gas turbine power cycle

Description: The Energy and Environmental Research Corporation (EER), the Ohio Agricultural Research and Development Center (OARDC), the Will-Burt Company (W-B) and the US Department of Energy (DOE) have successfully developed and completed pilot plant tests on a small scale atmospheric fluidized bed combustion (AFBC) system. This system can be used to generate electricity, and/or hot water, steam. Following successful pilot plant operation, commercial demonstration will take place at Cedar Lane Farms (CLF), near Wooster, Ohio. The system demonstration will be completed by the end of 1995. The project is being funded through a cooperative effort between the DOE, EER, W-B, OARDC, CLF and the Ohio Coal Development Office (OCDO). The small scale AFBC, has no internal heat transfer surfaces in the fluid bed proper. Combining the combustor with a hot air gas turbine (HAGT) for electrical power generation, can give a relatively high overall system thermal efficiency. Using a novel method of recovering waste heat from the gas turbine, a gross heat rate of 13,500 Btu/kWhr ({approximately}25% efficiency) can be achieved for a small 1.5 MW{sub e} plant. A low technology industrial recuperation type gas turbine is used that operates with an inlet blade temperature of 1,450 F and a compression ratio of 3.9:1. The AFBC-HAGT technology can be used to generate power for remote rural communities to replace diesel generators, or can be used for small industrial co-generation applications.
Date: December 31, 1995
Creator: Ashworth, R.A.; Keener, H.M. & Hall, A.W.
Partner: UNT Libraries Government Documents Department

Preliminary business plan: District Heating Company for the city of Handlova, Slovakia

Description: The city of Handlova, Slovakia, needs to replace its district heating system, which is old, unreliable, and expensive to maintain. The current plant is owned by a state-run utility, the Slovensky Energeticky Podnik (SEP). The plan is to privatize the heating plant, acquire capital to rehabilitate the central plant (converting it to a cogeneration facility), install a new hot-water distribution system, and implement an extensive energy efficiency effort in the residential buildings on the system. System capacity is 100 MWt, with annual heat sales estimated to be 450,000 gigajoules per year (GJ/yr). The capital necessary for system improvements is estimated to be 465 million Slovakian Krowns (SK) (in 1997 price levels). The total market value of existing fixed assets that will survive the rehabilitation effort as part of the new systems is estimated at 342 million SK. There has been substantial analysis and preparation for this activity, which is documented in demand-side and supply-side technical and economic analyses, an integrated demand/supply report, and this preliminary business plan. The preparation includes investigation of ownership, management, and technology alternatives; estimation of the market value of existing assets and investment requirements; and forecasting of future cash flows. These preliminary projections indicate that the cost of heating from the new system will be reasonable from both a cost per unit of energy basis (SK/GJ) and, form the perspective of an apartment dweller in Handlova, on a total cost per year basis. Delivering heat at the projected cost will, however, require a substantial change in the way that the heating plant is run, with proportionally very large reductions in labor, operations and maintenance, and overhead charges. In addition, there will need to be significant revenues from the sale of electricity to the national grid.
Date: June 1, 1996
Partner: UNT Libraries Government Documents Department

The solar thermal report. Volume 3, Number 5

Description: This report is published by the Jet Propulsion Laboratory for the DOE Solar Thermal Technology Division to provide an account of work sponsored by the Division and to aid the community of people interested in solar thermal technology in gaining access to technical information. Contents include articles entitled the following: Solar system supplies thermal energy for producing chemicals at USS plant; Solar thermal power module designed for small community market; Roof-mounted trough system supplies process heat for Caterpillar plant; Solar thermal update -- 10 MW(e) pilot plant and 3-MW(t) total energy system; Solar steam processes crude oil; New York investigates solar ponds as a source of thermal energy; On-farm solar -- Finding new uses for the sun; and Topical index of solar thermal report articles.
Date: September 1, 1982
Partner: UNT Libraries Government Documents Department

Innovative hybrid gas/electric chiller cogeneration

Description: January Progress--A kick-off meeting was held in San Diego with Alturdyne on January 21st. The proposed hybrid gas/electric chiller/cogenerator design concept was discussed in detail. The requirements and functionality of the key component, a variable speed, constant frequency motor/generator was presented. Variations of the proposed design were also discussed based on their technical feasibility, cost and market potential. The discussion is documented in a Trip Report. February Progress--After significant GRI/Alturdyne discussion regarding alternative product design concepts, the team made a decision to continue with the proposed product design, a hybrid chiller capable of also providing emergency power. The primary benefits are: (a) the flexibility and operating cost savings associated with the product's dual fuel capability and (b) the emergency power feature. A variable speed, constant frequency motor/generator would significantly increase the cost of the product while providing marginal benefit. (The variable speed, constant frequency motor generator is estimated to cost $25,000 versus $4,000 for a constant speed version). In addition, the interconnection requirements to the electric grid would significantly limit market penetration of the product. We will proceed with a motor/generator design capable of serving as the electric prime mover for the compressor as well as the generator for emergency power needs. This component design is being discussed with two motor manufacturers. The first generation motor/generator will not be a variable speed, constant frequency design. The variable speed, constant frequency capability can be an advancement that is included at a later time. The induction motor/synchronous generator starts as a wound rotor motor with a brushless exciter and control electronics to switch between induction mode and synchronous mode. The exciter is a three-phase exciter with three phase rotating diode assembly. In the induction motor mode, the field windings are shorted out by SCRs located across the field. In the synchronous mode, ...
Date: April 1, 2000
Creator: Nowakowski, G.
Partner: UNT Libraries Government Documents Department

Establishment of the International Power Institute

Description: Building on the two previous trips to Central America last year, International Power Institute (IPI) and its partner Tennessee Valley Infrastructure Group (TVIG) have focused their attention this quarter on project sites in Honduras. TVIG's unit--an Integrated Infrastructure Platform or IIP--combines water and electricity production in a single integrated unit, thereby providing both products at a lower cost than could be attained for each one separately. Because of the unmet demand for clean drinking water and electricity in remote towns throughout the developing world, the need for such units is widespread. Previous visits to Honduras have resulted in strong in-country commercial interest, support in the form of memorandums of understanding by key government agencies, and identification of four prospective project sites for IIP installations. From March 5 to March 15 and with IPI support and participation, representatives from the TVIG, Tennessee Valley Authority (TVA), IPI, and market research firm International Business Initiatives (IBI) conducted an intensive survey of project opportunities in the four communities, to establish how IIPs might help these four communities enhance their economic development, A key aspect of the projects examined is the need to make them economically self-supporting so that they will be viable in the private sector. Summary of specific project site studies follow here, and feasibility studies for the four sites are included as attachments.
Date: April 29, 2000
Creator: Coles, Julius E.
Partner: UNT Libraries Government Documents Department

Minnesota Agri-Power Project. Quarterly report, January--March, 1998

Description: The Minnesota Valley Alfalfa Producers propose to build an alfalfa processing plant integrated with an advanced power plant system at the Granite Falls, Minnesota industrial park to provide 75 MW of base load electric power and a competitively priced source of value added alfalfa based products. This project utilizes air blown fluidized bed gasification technology to process alfalfa stems and another biomass to produce a hot, clean, low heating value gas that will be used in a gas turbine. Exhaust heat from the gas turbine will be used to generate steam to power a steam turbine and provide steam for the processing of the alfalfa leaf into a wide range of products including alfalfa leaf meal, a protein source for livestock. This progress report describes feedstock testing, feedstock supply system, performance guarantees, sales contracts, environmental permits, education, environment, economy, and project coordination and control.
Date: May 1, 1998
Creator: Wilbur, D.
Partner: UNT Libraries Government Documents Department

Global carbon impacts of using forest harvest residues for district heating in Vermont

Description: Forests in Vermont are selectively logged periodically to generate wood products and useful energy. Carbon remains stored in the wood products during their lifetime and in fossil fuel displaced by using these products in place of energy-intensive products. Additional carbon is sequestered by new forest growth, and the forest inventory is sustained using this procedure. A significant portion of the harvest residue can be used as biofuel in central plants to generate electricity and thermal energy, which also displaces the use of fossil fuels. The impact of this action on the global carbon balance was analyzed using a model derived from the Graz/Oak Ridge Carbon Accounting Model (GORCAM). The analysis showed that when forests are harvested only to manufacture wood products, more than 100 years are required to match the sequestered carbon present if the forest is left undisturbed. If part of the harvest residue is collected and used as biofuel in place of oil or natural gas, it is possible to reduce this time to about 90 years, but it is usually longer. Given that harvesting the forest for products will continue, carbon emission benefits relative to this practice can start within 10 to 70 years if part of the harvest residue is used as biofuel. This time is usually higher for electric generation plants, but it can be reduced substantially by converting to cogeneration operation. Cogeneration makes possible a ratio of carbon emission reduction for district heating to carbon emission increase for electricity generation in the range of 3 to 5. Additional sequestering benefits can be realized by using discarded wood products as biofuels.
Date: July 1, 1998
Creator: McLain, H.A.
Partner: UNT Libraries Government Documents Department

Coal air turbine {open_quotes}CAT{close_quotes} program invention 604. Fourth quarter project report, July 1995--September 1995

Description: A coal air turbine `CAT` generates electric power and heat from coal combustion. The purpose of this project is the conceptual design of a `CAT` plant, and to make a comparison of the capital cost and and cost of power and steam from the `CAT` plant with power produced by alternate plants at the same site. Three configurations investigated include: condensing plant utilizing coal fuel and a condenser tower, or river, for cooling; a cogeneration plant utilizing coal and a steam turbine; and a cogeneration plant utilizing steam export and injection with waste coal fuel.
Date: October 31, 1995
Creator: Foster-Pegg, R.W.
Partner: UNT Libraries Government Documents Department