Remaining Sites Verification Package for 132-D-2, 117-D Filter Building, Waste Site Reclassification Form 2005-024

Description: The 132-D-2 site (117-D Filter Building) and associated below-grade ductwork were decommissioned and demolished in two phases in 1985 and 1986, with a portion of the rubble left in situ beneath clean fill at least 1 m (3.3 ft) thick. Decommissioning included removal of contaminated equipment, including filters. Residual concentrations support future land uses that can be represented by a rural-residential scenario and pose no threat to groundwater or the Columbia River based on RESRAD modeling.
Date: May 9, 2006
Creator: Carlson, R. A.
Partner: UNT Libraries Government Documents Department

Remaining Sites Verification Package for 132-H-1, 116-H Reactor Stack Burial Site, Waste Site Reclassification Form 2006-053

Description: The 132-H-1 waste site includes the 116-H exhaust stack burial trench and the buried stack foundation (which contains an embedded vertical 15-cm (6-in) condensate drain line). The 116-H reactor exhaust stack and foundation were decommissioned and demolished using explosives in 1983, with the rubble buried in situ beneath clean fill at least 1 m (3.3 ft) thick. Residual concentrations support future land uses that can be represented by a rural-residential scenario and pose no threat to groundwater or the Columbia River based on RESRAD modeling.
Date: June 26, 2007
Creator: Dittmer, L. M.
Partner: UNT Libraries Government Documents Department

Remaining Sites Verification Package for the 100-F-36, 108-F Biological Laboratory, and for the 116-F-15, 108-F Radiation Crib, Waste Site Reclassification Form 2007-002

Description: The 100-F-36 waste site is the location of the former 108-F Biological Laboratory. The building was closed in 1973, decontaminated, decommissioned, and eventually demolished in 1999. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.
Date: May 24, 2007
Creator: Dittmer, L. M.
Partner: UNT Libraries Government Documents Department

Remaining Sites Verification Package for the 132-F-1, 141-F Chronic Feeding Sheep Barn, Waste Site Reclassification Form 2006-029

Description: The 132-F-1 site is the former location of the 141-F Chronic Feeding Sheep Barn that was part of the experimental animal farm at the 100-F Area. It was an L-shaped concrete block building with a concrete floor and concrete animal pens located both inside and outside the building. The 141-F Building was demolished in 1977 following relocation of animal research to the 300 Area. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.
Date: August 23, 2006
Creator: Dittmer, L. M.