Search Results

Advanced search parameters have been applied.
open access

Studies of evaporative and conventional cooling of an energy conserving California house

Description: For cooling a Sacramento, California home, (1) higher thermostat settings, (2) insulation (3) ''solar control'' window shades, and (4) the use of an evaporative cooler in the place of a vapor compression cycle air conditioner are studied. A computer program TWOZONE is used to evaluate the effect on energy consumption and peak power. It is calculated that the peak cooling load can be reduced by a factor of 5 or more and the total energy by a factor of 20 or more.
Date: March 1, 1978
Creator: Gates, S.D.; Baughn, J. & Rosenfeld, A.H.
Partner: UNT Libraries Government Documents Department
open access

Heating/daylighting prototype development. Phase I, Passive and Hybrid Solar Manufactured Building Project. Interim report and project status report No. 1, 1 October 1979-29 February 1980

Description: Climatological data, both representative (typical) and extreme conditions, relevant to building energy use in Grandview, Missouri are presented. The energy-related characteristics of a particular building and its use are merged with ambient weather conditions. The graphs depict daily fluctuations in the major categories of building heating/cooling load for the experimental building (Roof Runner facility) at Butler Research Center. Data input include hourly weather and building occupancy schedul… more
Date: March 31, 1980
Creator: Snyder, M.; Fraker, H.; Lindsey, L.; Braham, W.; Hallagan, W. & Huffman, J.
Partner: UNT Libraries Government Documents Department
open access

Optimal forced-air distribution in new housing

Description: This paper summarizes a system integration approach to residential heating, cooling, and ventilation, embodied in a tight building envelope with precooling and dehumidification of forced ventilation air, and with ducts in the conditioned space.
Date: May 1, 1992
Creator: Andrews, J. W.
Partner: UNT Libraries Government Documents Department
open access

Phoenix City of Colorado Springs Solar Assisted Heat Pump Project. Technical report, July 1--September 1977

Description: The work completed to date in documenting the design of packaged Solar Assisted Optimized Heat Pump (SAOHP) systems as a step towards stimulating the advancement of an industrial, commercial, and professional capability for producing and distributing this type of system is covered. The SAOHP system consists of a collector group, a storage group, and an energy transport group. The design for the collector group with first tier parts and assembly lists are included, along with the energy transpor… more
Date: October 1, 1977
Creator: Jardine, D.M. & Jones, D.W.
Partner: UNT Libraries Government Documents Department
open access

Systems analysis techniques for annual cycle thermal energy storage solar systems

Description: Community-scale annual cycle thermal energy storage (ACTES) solar systems are promising options for building heat and cooling. A variety of approaches are feasible in modeling ACTES solar systems. The key parameter in such efforts, average collector efficiency, is first examined, followed by several approaches for simple and effective modeling. Methods are also examined for modeling building loads for structures based on both conventional and passive architectural designs. Two simulation models… more
Date: July 1, 1980
Creator: Baylin, F. & Sillman, S.
Partner: UNT Libraries Government Documents Department
open access

Intermediate photovoltaic system application experiment operational performance report. Volume 5 for Lovington Square Shopping Center, Lovington, NM

Description: For the months of September and October, 1981, operational performance data are presented for a photovoltaic power system at a New Mexico shopping center. The electrical energy yield, incident solar energy, and efficiency of the solar cell array are given, including daily and monthly energy yield and insolation and efficiency, and energy yield as a function of power level, voltage, cell temperature, and hour of the day. Data are presented for two power conditioning units, including power condit… more
Date: December 1, 1981
Partner: UNT Libraries Government Documents Department
open access

Assessment of a geothermal application at Tucson, Arizona

Description: This study assessed the potential of using a geothermal energy source thought to underlie a large computer company's new facility near Tucson, Arizona. This energy source would be used with existing technology to meet the air conditioning and heating requirements of the proposed one million-square-foot expansion that would double the size of the facility. Cost data generated in this study could also be used to make economic determinations of retrofitting the existing, electrically driven centri… more
Date: March 1, 1982
Creator: Keller, J.G.
Partner: UNT Libraries Government Documents Department
open access

Intermediate photovoltaic system application experiment operational performance report. Volume 7, for Newman Power Station, El Paso, TX

Description: Performance data are given for the month of December, 1981 for a photovoltaic power supply at a Texas power station. Data include: monthly and daily electric energy produced; monthly and daily solar energy received; monthly and daily array efficiency; plots of energy produced as a function of power level, voltage, cell temperature, and hour of the day; monthly and daily electrical energy supplied by the photovoltaic system to the load; daily system availability; monthly and hourly insolation; m… more
Date: January 1, 1982
Partner: UNT Libraries Government Documents Department
open access

Diagnostic tests determining the thermal response of a house

Description: Two different approaches to the determination of the thermal response of buildings are possible: deterministic models and methods based on equivalent thermal parameters (ETP's) of a building. While the former are computer applications of heat transfer theory, the latter consist of data oriented techniques that infer the ETP's of a particular building by multiple correlation of indoor temperature and weather. The ETP method is convenient to provide a rank ordering of different houses by their th… more
Date: November 1, 1977
Creator: Sonderegger, R.
Partner: UNT Libraries Government Documents Department
open access

Economic analysis of the integrated heating and cooling potential of a residential passive-solar water wall design

Description: The heating potential of residential water wall designs has been analyzed for many years. Because this past work has been confined strictly to heating potential, it has understated the true energy savings potential of water walls. Preliminary performance estimates for the heating and cooling potential of water walls have recently been made available. These estimates include the Btu displacement that is attributable to a 300-square foot water wall design in a 1200-square foot residence. The desi… more
Date: January 1, 1982
Creator: Roach, F.; Mangeng, C.; Kirschner, C. & Ben-David, S.
Partner: UNT Libraries Government Documents Department
open access

Comparative Study of Four Passive Building Energy Simulations DOE 2.1, BLAST, SUNCAT 2.4, DEROB-III

Description: Four building energy analysis codes are compared using two direct gain building models with Madison TMY weather data. Hourly temperature profiles and annual heating and cooling loads are compared and discussed. An analytic verification technique is described and used to investigate performance of the four codes. An anomaly is discovered in one of the codes, and the analytic verification technique is used to test a modified version of this code.
Date: October 1, 1980
Creator: Judkoff, R.; Wortman, D.; Christensen, C.; O'Doherty, R.; Simms, D. & Hannifan, M.
Partner: UNT Libraries Government Documents Department
open access

Evaluation of the typical meteorological years for solar heating and cooling system studies. Final report

Description: This report is a summary of an evaluation of the weather data set, generated at Sandia Laboratories, known as the Typical Meteorological Year (TMY) Data. The purpose of the evaluation is to determine how well the TMY data represent actual long-term weather data in affecting the performance of solar heating and cooling systems. The two data sets are compared through detailed SHAC simulation.
Date: December 1, 1979
Creator: Freeman, T. L.
Partner: UNT Libraries Government Documents Department
open access

Analysis methods for solar heating and cooling applications: passive and active systems. 2nd edition

Description: Brief descriptions of analysis methods and design tools which are valuable in performing parametric studies of candidate designs are presented in this brochure. The methods included range from rules-of-thumb for builders to the simulation packages used by researchers. (MHR)
Date: January 1, 1980
Partner: UNT Libraries Government Documents Department
open access

Solar photovoltaic/thermal residential systems

Description: The results of a conceptual design study using computer simulations to determine the physical and economic performance of combined photovoltaic/thermal collector heat-pump solar systems for a single-family residence are presented. Economic analyses are based upon projected costs for a 1986 system installation. The results show that PV/T collector systems can be economically competitive for a cold climate residence, that systems employing on-site electrical storage batteries are not economically… more
Date: December 28, 1979
Creator: Russell, M.C.
Partner: UNT Libraries Government Documents Department
open access

Passive solar calculation methods. Interim report

Description: This report is the first in a series and details the results accomplished under the following tasks: (1) evaluation of existing passive solar calculation methods, (2) BLAST/DOE-1 program interface and comparison with BR-202, and (3) development of analytic relationships between the thermal balance and weighting factor techniques. The various methods available for use in thermal load analysis are presented with detailed informaton on algorithms used in the thermal balance and weighting factor te… more
Date: April 15, 1979
Partner: UNT Libraries Government Documents Department
open access

Furnace Blower Electricity: National and Regional Savings Potential

Description: Currently, total electricity consumption of furnaces is unregulated, tested at laboratory conditions using the DOE test procedure, and is reported in the GAMA directory as varying from 76 kWh/year to 1,953 kWh/year. Furnace blowers account for about 80percent of the total furnace electricity consumption and are primarily used to distribute warm air throughout the home during furnace operation as well as distribute cold air during air conditioning operation. Yet the furnace test procedure does n… more
Date: May 16, 2008
Creator: Center, Florida Solar Energy; Franco, Victor; Franco, Victor; Lutz, Jim; Lekov, Alex & Gu, Lixing
Partner: UNT Libraries Government Documents Department
open access

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)

Description: The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air sys… more
Date: July 1, 2007
Creator: Xu, Tengfang & Greenberg, Steve
Partner: UNT Libraries Government Documents Department
open access

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

Description: The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidif… more
Date: June 18, 2008
Creator: Hoeschele, M.A. & Springer, D.A.
Partner: UNT Libraries Government Documents Department
open access

High-Efficiency Variable Dehumidification for Air Conditioners: ClimaStat

Description: Advantek has successfully developed the first low-cost technology offering significant improvement in both Seasonal Energy Efficiency (SEER) and comfort & humidity control. A production prototype was constructed based on a commercial roof top package unit. The prototype was operated under a wide range of psychrometric conditions. Test data was analyzed to identify refinements, which were implemented to further improve performance in an iterative procedure that resulted in a fully optimized tech… more
Date: April 30, 2006
Creator: West, Michael K.
Partner: UNT Libraries Government Documents Department
open access

Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks

Description: The Advanced Electric Systems and Aerodynamics for Efficiency Improvements in Heavy Duty Trucks program (DE-FC26-04NT42189), commonly referred to as the AES program, focused on areas that will primarily benefit fuel economy and improve heat rejection while driving over the road. The AES program objectives were to: (1) Analyze, design, build, and test a cooling system that provided a minimum of 10 percent greater heat rejection in the same frontal area with no increase in parasitic fan load. (2)… more
Date: October 31, 2007
Creator: Slone, Larry & Birkel, Jeffrey
Partner: UNT Libraries Government Documents Department
open access

Manufactured Home Energy Audit (MHEA)Users Manual (Version 7)

Description: The Manufactured Home Energy Audit (MHEA) is a software tool that predicts manufactured home energy consumption and recommends weatherization retrofit measures. It was developed to assist local weatherization agencies working with the U.S. Department of Energy (DOE) Weatherization Assistance Program. Whether new or experienced, employed within or outside the Weatherization Assistance Program, all users can benefit from incorporating MHEA into their manufactured home weatherization programs. DOE… more
Date: January 27, 2003
Creator: Gettings, M.B.
Partner: UNT Libraries Government Documents Department
open access

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

Description: This report presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover… more
Date: September 30, 2008
Creator: Lu, Ning; Taylor, Zachary T.; Jiang, Wei; Xie, YuLong; Leung, Lai R.; Correia, James et al.
Partner: UNT Libraries Government Documents Department
open access

Advanced Energy Efficient Roof System

Description: Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, incl… more
Date: September 30, 2008
Creator: Davidson, Jane
Partner: UNT Libraries Government Documents Department
Back to Top of Screen