Viscoelastic coupling of nanoelectromechanical resonators.

Description: This report summarizes work to date on a new collaboration between Sandia National Laboratories and the California Institute of Technology (Caltech) to utilize nanoelectromechanical resonators designed at Caltech as platforms to measure the mechanical properties of polymeric materials at length scales on the order of 10-50 nm. Caltech has succeeded in reproducibly building cantilever resonators having major dimensions on the order of 2-5 microns. These devices are fabricated in pairs, with free ends separated by reproducible gaps having dimensions on the order of 10-50 nm. By controlled placement of materials that bridge the very small gap between resonators, the mechanical devices become coupled through the test material, and the transmission of energy between the devices can be monitored. This should allow for measurements of viscoelastic properties of polymeric materials at high frequency over short distances. Our work to date has been directed toward establishing this measurement capability at Sandia.
Date: September 1, 2009
Creator: Simonson, Robert Joseph & Staton, Alan W.
Partner: UNT Libraries Government Documents Department

Mass-Transport-Limited Electrodeposition of High-Surface-Area Coatings for Surface Acoustic Wave Sensor Technology

Description: The sensitivity of surface acoustic wave (SAW) sensors has been enhanced by increasing the active surface area of these devices. Electrodepositions of Ni, Pd, and Pt in a mass-transport-limited mode with trace foreign metals yield highly dendritic crystal structures of uniform macroscopic thickness. The concentration of metal ions, supporting electrolyte, agitation, and additives greatly impact the crystal morphology of the deposit. This methodology can be used simply and economically to provide high-area films in selective regions.
Date: June 10, 1999
Creator: Ricco, Antonio J.; Staton, Alan W. & Yelton, W. Graham
Partner: UNT Libraries Government Documents Department

Nanoporous-carbon adsorbers for chemical microsensors.

Description: Chemical microsensors rely on partitioning of airborne chemicals into films to collect and measure trace quantities of hazardous vapors. Polymer sensor coatings used today are typically slow to respond and difficult to apply reproducibly. The objective of this project was to produce a durable sensor coating material based on graphitic nanoporous-carbon (NPC), a new material first studied at Sandia, for collection and detection of volatile organic compounds (VOC), toxic industrial chemicals (TIC), chemical warfare agents (CWA) and nuclear processing precursors (NPP). Preliminary studies using NPC films on exploratory surface-acoustic-wave (SAW) devices and as a {micro}ChemLab membrane preconcentrator suggested that NPC may outperform existing, irreproducible coatings for SAW sensor and {micro}ChemLab preconcentrator applications. Success of this project will provide a strategic advantage to the development of a robust, manufacturable, highly-sensitive chemical microsensor for public health, industrial, and national security needs. We use pulsed-laser deposition to grow NPC films at room-temperature with negligible residual stress, and hence, can be deposited onto nearly any substrate material to any thickness. Controlled deposition yields reproducible NPC density, morphology, and porosity, without any discernable variation in surface chemistry. NPC coatings > 20 {micro}m thick with density < 5% that of graphite have been demonstrated. NPC can be 'doped' with nearly any metal during growth to provide further enhancements in analyte detection and selectivity. Optimized NPC-coated SAW devices were compared directly to commonly-used polymer coated SAWs for sensitivity to a variety of VOC, TIC, CWA and NPP. In every analyte, NPC outperforms each polymer coating by multiple orders-of-magnitude in detection sensitivity, with improvements ranging from 103 to 108 times greater detection sensitivity! NPC-coated SAW sensors appear capable of detecting most analytes tested to concentrations below parts-per-billion. In addition, the graphitic nature of NPC enables thermal stability > 600 C, several hundred degrees higher than the polymers. This ...
Date: November 1, 2004
Creator: Overmyer, Donald L.; Siegal, Michael P.; Staton, Alan W.; Provencio, Paula Polyak & Yelton, William Graham
Partner: UNT Libraries Government Documents Department

Microcalibrator system for chemical signature and reagent delivery.

Description: Networked systems of low-cost, small, integrable chemical sensors will enable monitoring of Nonproliferation and Materials Control targets and chemical weapons threats. Sandia-designed prototype chemical sensor systems are undergoing extended field testing supported by DOE and other government agencies. A required surety component will be verification of microanalytical system performance, which can be achieved by providing a programmable source of chemical signature(s) for autonomous calibration of analytical systems. In addition, such a controlled chemical source could be used to dispense microaliquots of derivatization reagents, extending the analysis capability of chemical sensors to a wider range of targets. We have developed a microfabricated system for controlled release of selected compounds (calibrants) into the analytical stream of microsensor systems. To minimize pumping and valve requirements of microfluidic systems, and to avoid degradation issues associated with storage of dilute solutions, we have utilized thermally labile organic salts as solid-phase reservoir materials. Reproducible deposition of tetrapropyl ammonium hydroxide onto arrays of microfabricated heating elements can provide a pair of calibration marker compounds (one fast and one slow-eluting compound) for GC analyses. The use of this microaliquot gas source array for hydrogen generation is currently under further development. The goal of the latter effort will be to provide a source of high-pressure, low viscosity GC carrier gas for Sandia's next-generation microfabricated gas-phase chemical analysis systems.
Date: March 1, 2005
Creator: Staton, Alan W.; Simonson, Robert Joseph; Adkins, Douglas Ray; Rawlinson, Kim Scott; Robinson, Alex Lockwood; Hance, Bradley G. et al.
Partner: UNT Libraries Government Documents Department

Detection of Volatile Organics Using a Surface Acoustic Wave Array System

Description: A chemical sensing system based on arrays of surface acoustic wave (SAW) delay lines has been developed for identification and quantification of volatile organic compounds (VOCs). The individual SAW chemical sensors consist of interdigital transducers patterned on the surface of an ST-cut quartz substrate to launch and detect the acoustic waves and a thin film coating in the SAW propagation path to perturb the acoustic wave velocity and attenuation during analyte sorption. A diverse set of material coatings gives the sensor arrays a degree of chemical sensitivity and selectivity. Materials examined for sensor application include the alkanethiol-based self-assembled monolayer, plasma-processed films, custom-synthesized conventional polymers, dendrimeric polymers, molecular recognition materials, electroplated metal thin films, and porous metal oxides. All of these materials target a specific chemical fi.mctionality and the enhancement of accessible film surface area. Since no one coating provides absolute analyte specificity, the array responses are further analyzed using a visual-empirical region-of-influence (VERI) pattern recognition algorithm. The chemical sensing system consists of a seven-element SAW array with accompanying drive and control electronics, sensor signal acquisition electronics, environmental vapor sampling hardware, and a notebook computer. Based on data gathered for individual sensor responses, greater than 93%-accurate identification can be achieved for any single analyte from a group of 17 VOCs and water.
Date: October 14, 1999
Creator: ANDERSON, LAWRENCE F.; BARTHOLOMEW, JOHN W.; CERNOSEK, RICHARD W.; COLBURN, CHRISTOPHER W.; CROOKS, R.M.; MARTINEZ, R.F. et al.