A Comparison of the Nuclear Defense Capabilities of Nuclear and Coal-Fired Power Plants

Description: Report comparing civil defense capabilities of 300-MWe nuclear and coal-fired power generation stations. The report evaluates the economics and feasibility of plant protection from nuclear attack by plant hardening, remote sitting, and utilizing option fueling options for coal-fired plants. (pg. 1)
Date: May 1962
Creator: Brookhaven National Laboratory
Partner: UNT Libraries Government Documents Department
open access

Power Cost Normalization Studies Civilian Power Reactor Program - 1959

Description: Introduction: In connection with the development of a comprehensive plan for a ten year civilian power reactor program, the Evaluation and Planning Branch, Division of Reactor Development, United States Atomic Energy Commission has had a series of status reports prepared to present a comprehensive review of the technical and economic status of various nuclear power reactor concepts.
Date: January 1960
Creator: Sargent & Lundy
Partner: UNT Libraries Government Documents Department
open access

Reactor Containment Design Study

Description: Introduction: Sargent & Lundy was authorized on November 1, 1960, to make an economic and technical feasibility study of various reactor containment designs which are being utilized for several power plants now under construction.
Date: May 18, 1961
Creator: Johnson, R. A. & Nelson, I.
Partner: UNT Libraries Government Documents Department
open access

Supplement to Reactor Containment Design Study

Description: Summary: Report SL-1868 is a technical and economic feasibility study of four containment methods, i.e., standard containment, pressure relief, pressure supression and low pressure containment, for 44 MWe direct cycle and 180 and 300 MWe dual cycle boiling water reactor plants.
Date: April 23, 1962
Creator: Johnson, R. A. & Nelson, I.
Partner: UNT Libraries Government Documents Department
open access

Nuclear-Conventional Power Plant Cost Study. Conventional Coal Fired Power Plants : 25,000 KW to 325,000 KW for Argonne National Laboratory, Lemont, Illinois

Description: In order to establish a basis for comparing the estimated cost of nuclear power plant designs, a set of general and detailed design considerations for conventional coal-fired power plants was established. Five preliminary designs of conventional coal-fired power plants ranging in size from 25to 325 mw were selected, and cost estimates were prepared. ( A.C.)
Date: March 2, 1959
Creator: Chittenden, W. A.
Partner: UNT Libraries Government Documents Department
open access

Supplement No. 1. Projections of Costs, 1959-1975 for Nuclear-Conventional Power Plant Cost Study. Conventional Coal Fired Power Plants : 25,000 KW to 325,000 KW for Argonne National Laboratory, Lemont, Illinois

Description: In order to establish a basis for comparing the estimated cost of nuclear power plant designs, a set of general and detailed design considerations for conventional coal-fired power plants was established. Five preliminary designs of conventional coal-fired power plants ranging in size from 25to 325 mw were selected, and cost estimates were prepared. Supplement 1 shows a year by year projection of costs for the period 1959-1975.
Date: July 2, 1959
Creator: Chittenden, W. A.
Partner: UNT Libraries Government Documents Department
open access

Supplement No. 2. Supplemental Data for Nuclear-Conventional Power Plant Cost Study. Conventional Coal Fired Power Plants : 25,000 KW to 325,000 KW for Evaluation and Planning Branch, Division of Reactor Development, Atomic Energy Commission

Description: In order to establish a basis for comparing the estimated cost of nuclear power plant designs, a set of general and detailed design considerations for conventional coal-fired power plants was established. Five preliminary designs of conventional coal-fired power plants ranging in size from 25to 325 mw were selected, and cost estimates were prepared. Supplement No. 2 furnishes the following requested information.: (1) Projected investments costs, 1959-1975 for each of the five unites sizes; (2) … more
Date: September 1, 1959
Creator: Chittenden, W. A.
Partner: UNT Libraries Government Documents Department
open access

An Analytical Study of Seismic Threat to Containment Integrity

Description: Report providing quantitative information of containment seismic capacity considering a rather complete list of limit states along with a discussion of factors that are significant for determining seismic capacity and recommendations for future work.
Date: June 1989
Creator: Amin, M.; Agrawal, P. K. & Ahl, T. J.
Partner: UNT Libraries Government Documents Department
open access

Cost of Containment Features for Boiling Water Reactors for Argonne National Laboratory

Description: An analysis of the cost of containment features for nuclear power plants utilizing boiling water reactors was made. The two plants chosen for comparison were the Experimental Boiling Water Reactor at ANL and a hypothetical large scale nuclear power plant with an electrical capacity of 180 Mw. In order that a cost analysis could be made for the plant designs general arrangement drawings were prepared for each of the alternate arrangements considered.
Date: October 15, 1957
Partner: UNT Libraries Government Documents Department