4 Matching Results

Search Results

Advanced search parameters have been applied.

PROGRESS IN 2 mm GLOW DISCHARGE POLYMER MANDREL DEVELOPMENT FOR NIF

Description: OAK-B135 All planned National Ignition Facility (NIF) capsule targets except machined beryllium require a glow discharge polymer (GDP) mandrel upon which the albator is applied. This mandrel, {approx} 2 mm in diameter, must at least meet if not exceed the symmetry and surface finish requirements of the final capsule. Such mandrels are currently produced by the three-step depolymerizable mandrel technique. The quality of the final mandrel depends upon precise optimization and execution of each of the three steps. They had shown previously that fabrication of a mandrel which met the symmetry and surface finish requirements was feasible using this technique. In this paper they will discuss recent progress towards converting this process into a high yield, production scale process.
Date: June 1, 2003
Creator: NIKROO,A; BOUSQUET,J; COOK,R; McQUILLAN,B.W; PAGUIO,R & TAKAGI,M
Partner: UNT Libraries Government Documents Department

FABRICATION AND PROPERTIES OF OER COATED RESORCINOL-FORMALDEHYDE SHELLS FOR OMEGA EXPERIMENTS

Description: OAK-B135 New high gain designs for direct drive ignition on NIF require foam shells. Scaled down versions of these designs are needed for near term experiments on the OMEGA laser facility at the Laboratory Laser Energetics (LLE). These shells need to be about 1 mm in diameter and 50-100 {micro}m wall thickness and densities of 100-250 mg/cc. In addition, a full density permeation seal needs to be deposited for retention of the fill gas at room temperature or the ice at cryogenic temperatures. They have fabricated such shells using Resorcinol-formaldehyde (R/F) as the selected foam material due to its transparency in the optical region. Extensive characterization of the wall uniformity of these shells has been performed. The foam shells have {approx} 5%-6% non-concentricities on the average. A full density permeation seal has been deposited on the R/F shells using two different techniques. In the first technique R/F shells are coated directly with plasma polymer to thicknesses of 3-4 {micro}m. In the second technique, R/F shells are coated with polyvinylphenol, using a chemical interfacial polymerization technique. Data on surface finish and gas retention for R/F shells coated by both methods are provided.
Date: June 1, 2003
Creator: NIKROO,A; CZECHOWICZ,D; PAGUIO,R; GREENWOOD,A.L & TAKAGI,M
Partner: UNT Libraries Government Documents Department

HYDRODYNAMIC ISSUES IN PAMS MANDREL TARGET FABRICATION

Description: OAK-B135 Imperfections in PAMS mandrels critically govern the quality of final ICF targets. Imperfections in the mandrels can have a wide range of origins. Here, they present observations of 3 types of imperfections, and data to support the proposal that hydrodynamic factors during the curing of the mandrel are potential causes of these imperfections.
Date: September 1, 2003
Creator: McQUILLAN,B.W; PAGUIO,R; SUBRAMANIAN,P; TAKAGI,M & ZEBIB,A
Partner: UNT Libraries Government Documents Department

Neutron spectrometry - An essential tool for diagnosing implosions at the National Ignition Facility

Description: DT neutron yield (Y{sub n}), ion temperature (T{sub i}) and down-scatter ratio (dsr) determined from measured neutron spectra are essential metrics for diagnosing the performance of Inertial Confinement Fusion (ICF) implosions at the National Ignition Facility (NIF). A suite of neutron-Time-Of-Flight (nTOF) spectrometers and a Magnetic Recoil Spectrometer (MRS) have been implemented in different locations around the NIF target chamber, providing good implosion coverage and the redundancy required for reliable measurements of Yn, Ti and dsr. From the measured dsr value, an areal density ({rho}R) is determined from the relationship {rho}R{sub tot} (g/cm{sup 2}) = (20.4 {+-} 0.6) x dsr{sub 10-12 MeV}. The proportionality constant is determined considering implosion geometry, neutron attenuation and energy range used for the dsr measurement. To ensure high accuracy in the measurements, a series of commissioning experiments using exploding pushers have been used for in situ calibration. The spectrometers are now performing to the required accuracy, as indicated by the good agreement between the different measurements over several commissioning shots. In addition, recent data obtained with the MRS and nTOFs indicate that the implosion performance of cryogenically layered DT implosions, characterized by the experimental Ignition Threshold Factor (ITFx) which is a function of dsr (or fuel {rho}R) and Y{sub n}, has improved almost two orders of magnitude since the first shot in September, 2010.
Date: May 2, 2012
Creator: Mackinnon, A J; Johnson, M G; Frenje, J A; Casey, D T; Li, C K; Seguin, F H et al.
Partner: UNT Libraries Government Documents Department