Search Results

Advanced search parameters have been applied.
open access

Investigation and Preparation of Polymer Films to Improve the Separation of Water and Salts in Saline Water Conversion

Description: From Introduction: "As will be explained in more detail elsewhere in this report, casting methods and drying conditions have been found to have a drastic effect on film permeability to both water and salt. Errors that became evident in temperature control indicated that some of the previous high rates were obtained at temperatures considerably higher than the 100 degrees C that was intended and reported."
Date: December 1962
Creator: Monsanto Research Corporation
Partner: UNT Libraries Government Documents Department
open access

Thermodynamic Properties of Saline Water

Description: From Abstract: "Activity coefficients of calcium sulfate were calculated from solubilities of gypsum in 0 to 1.0m sodium chloride at temperatures from 25 degrees C to 95 degrees C. X-ray diffraction studies for calcium sulfate modifications before and after contact with aqueous and saline solutions are given."
Date: July 1964
Creator: Power, W. H. & Fabuss, B. M.
Partner: UNT Libraries Government Documents Department
open access

Reclamation of Polyphenyl Nuclear Reactor Coolant by Solvent Treatment

Description: Laboratory studies were conducted to develop methods to reclaim degraded terphenyl nuclear reactor coolant. A solvent treatment process to reclaim high boiler or spent coolant is described. A preliminary evaluation of the reclamation process is presented. Technical evaluation of products as well as a theoretical analysis of the effects of reclaimed coolant on coolant decomposition rate and make-up rate is reported. A detailed description of all experimental work is also given.
Date: unknown
Creator: Scola, D. A. & Adams, J. S.
Partner: UNT Libraries Government Documents Department
open access

Studies of the Reclamatio of Organic Nuclear Reactor Coolant by Partial Hydrogenation of Polyphenyls

Description: The partial hydrogenation of o-, m-, and p-terphenyl at high temperatures (200-275°C) and pressures (1500-2500 psig) was studied to determine the initial path of the hydrogenation. These model studies were extended to damaged nuclear reactor coolant (high boiler or polyphenyl) in an effort to develop a reclamation process.
Date: unknown
Creator: Scola, D. A. & Adams, J. S.
Partner: UNT Libraries Government Documents Department
open access

11th Quarterly Progress Report Organic Coolant Reclamation, 15 December 1961 to 15 March 1962

Description: The solvent distribution reclamation process using 5, 10, 15, 22, 30, 40 and 50 wt % Core II HB in Santovax-OMP has been accomplished. Cost comparisons of several technically feasible reclamation processes, presented in an earlier report, were reevaluated and are tabulated
Date: unknown
Creator: Scola, D. A.; Adams, J. S. & Richiusa, C. C.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen