Vapor space characterization of Waste Tank 241-U-106 (in situ): Results from samples collected on 8/25/94

Description: This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-U-106 (referred to as Tank U-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 target analytes. Of these, six were observed above the 5-ppbv reporting cutoff. Ten organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv in two or more of the three samples collected and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 89% of the total organic components in Tank U-106. Methyl isocyanate, a compound of possible concern in Tank U-106, was not detected. Tank U-106 is on the Organic Watch List.
Date: October 1, 1995
Creator: Ligotke, M.W.; Lucke, R.B. & Pool, K.H.
Partner: UNT Libraries Government Documents Department

Waste Tank Vapor Program: Vapor space characterization of Waste Tank 241-T-107. Results from samples collected on January 18, 1995

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-T-107 (referred to as Tank T-107). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, I was observed above the 5-ppbv reporting cutoff. Six organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The estimated concentration of all 7 organic analytes observed in the tank headspace are listed in Table I and account for approximately 100% of the total organic components in Tank T-107. Two permanent gases, carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O), were also detected in the tank-headspace samples.
Date: June 1, 1995
Creator: Pool, K.H.; Lucke, R.B. & McVeety, B.D.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

Description: This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({le} 10{degrees}C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH{sub 3}, NO{sub 2}, and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).
Date: November 1, 1995
Creator: Lucke, R.B.; Clauss, T.W. & Ligotke, M.W.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-B-103: Results from samples collected on 2/8/95

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-B-103 (referred to as Tank B-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water vapor (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, five were observed above the 5-ppbv reporting cutoff. Twenty-six organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. Twenty-three TICs were measured in two or more SUMMA{trademark} canisters. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 66% of the total organic components in Tank BB-103. Two permanent gases, carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O), were also detected. Tank B-103 is on the Organic Watch List.
Date: October 1, 1995
Creator: Ligotke, M.W.; Pool, K.H. & Lucke, R.B.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-TX-105: Results from samples collected on December 20, 1994. Waste Tank Vapor Project

Description: This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-TX-105. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: June 1, 1995
Creator: Klinger, G.S.; Ligotke, M.W. & Lucke, R.B.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of Waste Tank 241-TY-104 (in situ): Results from samples collected on 8/5/94

Description: This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-TY-104 (referred to as Tank TY-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not performed. In addition, the authors looked for the 39 TO-14 compounds plus an additional 14 analytes. Of these, eight were observed above the 5-ppbv reporting cutoff. Twenty-four organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 86% of the total organic components in Tank TY-104. Tank TY-104 is on the Ferrocyanide Watch List.
Date: October 1, 1995
Creator: Ligotke, M.W.; Pool, K.H. & Lucke, R.B.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-TX-118: Results from samples collected on 12/16/94

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-TX-118 (referred to as Tank TX-118). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 3 were observed above the 5-ppbv reporting cutoff. Twenty three organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 84% of the total organic components in Tank TX-118. Two permanent gases, carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O), were also detected.
Date: October 1, 1995
Creator: Lucke, R.B.; Ligotke, M.W. & McVeety, B.D.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-BY-111: Results from samples collected on November 15, 1994

Description: This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-111 (referred to as Tank By-111). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The target analytes for TO- 14 compounds were extended to include 14 analytes identified by the Toxicological Review Panel for Tank C-103 and reported by Mahlum et al. (1994). Program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T.J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.7. The sample job was designated S4083, and samples wee collected by WHC on November 16, 1994, using the vapor sampling system (VSS). The results of the analyses are expected to be used to estimate the potential toxicity of tank-headspace gas as described in Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0.
Date: June 1, 1995
Creator: Lucke, R.B.; Ligotke, M.W. & McVeety, B.D.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-C-105: Results from samples collected on 2/16/94

Description: This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-105 (referred to as Tank C-105). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace. For organic analyses, six SUMMA{trademark} canisters were delivered to WHC on COC 0061 11 on 2/14/94. At the request of WHC, an additional six SUMMA{trademark} canisters were supplied on COC 005127 on 2/16/94. Samples were collected by WHC from the headspace of Tank C-105 through the VSS on 2/16/94, but only three SUMMA{sup {trademark}} canisters were returned to PNL using COC 0061 11 on 2/18/94. The canisters were stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until the time of the analysis. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions. The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).
Date: June 1, 1995
Creator: Clauss, T.W.; Lucke, R.B. & McVeety, B.D.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-U-106: Results from samples collected on March 7, 1995. Waste Tank Vapor Program

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-U-106 (referred to as Tank U-106). The results described here were obtained to support safety and toxicological evaluations. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O) Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. The NH{sub 3} concentration was 16% greater than that determined from an ISS sample obtained in August 1994; the H{sub 2}O concentration was about 10% less. In addition, quantitative results were obtained for the 39 TO-14 compounds plus an additional 14 analytes. Of these, 5 were observed in two or more canisters above the 5-ppbv reporting cutoff. Eleven organic tentatively identified compounds (TICS) were observed in two or more canisters above the reporting cutoff of (ca.) 10 ppbv and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations account for approximately 90% of the total organic components in Tank U-106. Three permanent gases, nitrous oxide (N{sub 2}O), hydrogen (H{sub 2}) and carbon dioxide (COD were also detected.
Date: July 1, 1995
Creator: Klinger, G.S.; Lucke, R.B. & McVeety, B.D.
Partner: UNT Libraries Government Documents Department

Development and validation of a preparation and cleanup method for hydrocarbon containing samples for the analysis of volatile organic compounds

Description: Samples obtained from the Hanford single shell tanks are contaminated with normal paraffin hydrocarbon (NPH) as hydrostatic fluid from the sampling process or can be native to the tank waste. The contamination is usually high enough that a dilution of up to several orders of magnitude may be required before the sample can be analyzed by the conventional purge and trap concentration followed by gas chromatography/mass spectrometry methodology. This can prevent detection and measurement of organic constituents that are present at lower concentration levels. To eliminate or minimize the problem, a sample cleanup method has been developed and validated and is presented in this document.
Date: April 1, 1992
Creator: Hoppe, E.W.; Lucke, R.B.; Ross, G.A. & Campbell, J.A.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-BY-108: Results from in situ sample collected on March 24, 1994. Waste Tank Vapor Project

Description: This document presents the details of the organic analysis that was performed on samples from the headspace of Hanford waste tank 241-BY-108. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: June 1, 1995
Creator: McVeety, B.D.; Lucke, R.B.; Clauss, T.W.; Fruchter, J.S. & Goheen, S.C.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-BY-105: Results from samples collected on 7/7/94

Description: This report describes organic and inorganic results from vapors of the Hanford single-shell waste storage Tank 241-BY-105 (referred to as Tank BY-105). The results described here were obtained to support safety and toxicological evaluations. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. Several organic analytes were quantitatively determined, but quantities of non-TO-14 analytes were only estimated. Approximately 40 tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppb, but standards for most of these were not available at the time of analysis, and their quantitative determination is beyond the scope of this study. The SUMMA{trademark} Canisters were also analyzed for components listed in U.S. Environmental Protection Agency (EPA) compendium Method TO-14. Of these only a few were observed above the 2-ppb detection limits. These are summarized in Table 3.1. Estimated quantitations also determined were of tentatively identified compounds (TICs). A summary of these results shows quantities of all TICs above the concentration of ca. 10 ppb. This consists of more than 40 organic analytes. The 6 organic analytes with the highest estimated concentrations are shown in Table 1. These 6 analytes account for approximately 45% of the total organic components in Tank BY-105. Detailed descriptions of the results appear in the text. Unlike tanks previously studied, normal paraffin hydrocarbons (NPHs) did not contribute significantly to the total organic concentration of the vapor headspace of Tank BY-105. The total concentration of TICs detected in the tank headspace samples was also much lower than that seen in other reported tanks averaging 6.5 Mg/m{sup 3} for all three canisters collected.
Date: May 1, 1995
Creator: Pool, K. H.; Ligotke, M. W.; Clauss, T. W.; Lucke, R. B.; McVeety, B. D.; McCulloch, M. et al.
Partner: UNT Libraries Government Documents Department

Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

Description: This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text.
Date: June 1, 1995
Creator: Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-BY-106: Results from samples collected through the vapor sampling system on July 8, 1994

Description: This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-BY-106. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1, 1995
Creator: Lucke, R.B.; Pool, K.H.; Ligotke, M.W.; Clauss, T.W.; McVeety, B.D.; Fruchter, J.S. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-BY-103 (in situ): Results from samples collected on May 5, 1994

Description: This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-BY-103. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: June 1, 1995
Creator: Ligotke, M.W.; Sharma, A.K.; McVeety, B.D.; Fruchter, J.S.; Pool, K.H.; Lucke, R.B. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-BY-107: Results from in situ sample collected on 3/25/94

Description: This report describes organic results from vapors of the Hanford single-shell waste storage Tank 241-BY-107 (referred to as Tank BY-107). Samples for selected inorganic compounds were obtained but not anlayzed (Section 2.0). Quantitative results were obtained for several organic analytes, but quantities of analytes not listed in US Environmental Protection Agency (EPA) compendium Method TO-14 were estimated. Approximately 80 tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and their quantitative determination is beyond the scope of this study. The SUMMATM canister samples were also analyzed for the 41 organic compounds listed in EPA compendium Method TO-14. Of these, only a few were observed above the 2-ppbv detection limits. These are summarized in Table 3.1. Estimated quantities were determined of tentatively identified compounds (TICs). A summary of these results shows quantities of all TICs above the concentration of ca. 10 ppbv. This consists of more than 80 organic analytes. The 12 organic analytes with the highest estimated concentrations are shown.
Date: June 1, 1995
Creator: Sharma, A.K.; Lucke, R.B.; Clauss, T.W.; McVeety, B.D.; Fruchter, J.S. & Goheen, S.C.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-C-106: Results from samples collected on February 15, 1994

Description: This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-C-106. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: June 1, 1995
Creator: McVeety, B.D.; Clauss, T.W.; Young, J.S.; Ligotke, M.W.; Goheen, S.C.; Lucke, R.B. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-BY-106 (in situ): Results from samples collected on 5/4/94 and 5/5/94

Description: This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-BY-106 (referred to as Tank BY-106). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds NH{sub 3}, NO{sub 2}, NO, HCN, and H{sub 2}O. Sampling for sulfur oxides was not requested. Organic compounds were also quantitatively determined. Twenty-three organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 41 standard TO-14 analytes. Of these, only a few were observed above the 2-ppbv detection limit. The 10 organic analytes with the highest estimated concentrations are listed in Table 1. The 10 analytes account for approximately 64% of the total organic components in Tank BY-106. Tank BY-106 is on the Ferrocyanide Watch List.
Date: April 1, 1995
Creator: Clauss, T.W.; Ligotke, M.W.; Pool, K.H.; Lucke, R.B.; McVeety, B.D.; Sharma, A.K. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-BY-105 (in situ): Results from samples collected on May 9, 1994

Description: This report describes inorganic and organic analyses results from in situ samples obtained from the tank headspace of the Hanford waste storage Tank 241-BY-105 (referred to as Tank BY-105). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds NH{sub 3}, NO{sub 2}, NO, HCN, and H{sub 2}O. Sampling for sulfur oxides was not requested. Results of the inorganic samples were affected by sampling errors that led to an undefined uncertainty in sample volume. Consequently, tank-headspace concentrations are estimated only. Thirty-nine tentatively identified organic analytes were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and their quantitation is beyond the scope of this study. In addition, we looked for the 41 standard TO-14 analytes. Of these, only a few were observed above the 2-ppbv detection limit. The 16 organic analytes with the highest estimated concentrations are listed. These 16 analytes account for approximately 68% of the total or organic components in Tank BY-105.
Date: May 1, 1995
Creator: McVeety, B.D.; Pool, K.H.; Ligotke, M.W.; Clauss, T.W.; Lucke, R.B.; Sharma, A.K. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-C-104: Results from samples collected on 2/17/94 and 3/3/94

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-C-104 (referred to as Tank C-104). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Summary Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), sulfur oxides (SO{sub x}), and water vapor (H{sub 2}O). Organic compounds were also quantitatively determined. Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were analyzed for tributyl phosphate. Twenty-four organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 40 standard TO-14 analytes. Of these, two were observed above the 2-ppbv calibrated instrument detection limit. The 10 organic analytes with the highest estimated concentrations are listed in Summary Table 1. These 10 analytes account for approximately 88% of the total organic components in Tank C 104. Tank C-104 is not on any of the Watch Lists.
Date: October 1, 1995
Creator: Lucke, R.B.; McVeety, B.D.; Clauss, T.W.; Pool, K.H.; Young, J.S.; McCulloch, M. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-C-111 (in situ): Results from samples collected on 6/20/94

Description: This report describes inorganic and organic analyses results from in situ samples obtained from the headspace of the Hanford waste storage Tank 241-C-111 (referred to as Tank C-111). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Summary Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), hydrogen cyanide (HCN), and water vapor (H{sub 2}O). Sampling for sulfur oxides was not requested. Organic compounds were quantitatively determined. Five organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 40 standard TO-14 analytes and observed 39. None of these compounds were above the 2-ppbv calibrated instrumental detection limit. However, it is believed that the detection of dichlorodifluoromethane and methyl benzene are real at these low concentrations. The five organic analytes with the highest estimated concentrations are listed in Summary Table 1. The five analytes account for approximately 100% of the total organic components in Tank C-111.
Date: October 1, 1995
Creator: Ligotke, M.W.; Pool, K.H.; Lucke, R.B.; McVeety, B.D.; Clauss, T.W.; McCulloch, M. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste Tank 241-C-108: Results from samples collected through the vapor sampling system on 8/5/94

Description: This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-C-108 (referred to as Tank C-108). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water vapor (H{sub 2}O). Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. Organic compounds were also quantitatively determined. Two organic tentatively identified compounds (TICs) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, the authors looked for the 41 standard TO-14 analytes. Of these, only a few were observed above the 2-ppbv detection limit. The five organic analytes with the highest estimated concentrations are listed in Table 1. The five analytes account for approximately 85% of the total organic components in Tank C-108.
Date: October 1, 1995
Creator: Lucke, R.B.; Ligotke, M.W.; Pool, K.H.; Clauss, T.W.; Sharma, A.K.; McVeety, B.D. et al.
Partner: UNT Libraries Government Documents Department

Vapor space characterization of waste tank 241-C-107 (in situ): Results from samples collected on June 17, 1994

Description: This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 241-C-107. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: June 1, 1995
Creator: McVeety, B.D.; Ligotke, M.W.; Lucke, R.B.; McCulloch, M.; Goheen, S.C.; Clauss, T.W. et al.
Partner: UNT Libraries Government Documents Department