PDX infrared TV camera system

Description: An infrared TV camera system has been developed for use on PDX. This system is capable of measuring the temporal and spatial energy deposition on the limiters and divertor neutralizer plates; time resolutions of 1 ms are achievable. The system has been used to measure the energy deposition on the PDX neutralizer plates and the temperature jump of limiter surfaces during a pulse. The energy scrapeoff layer is found to have characteristic dimensions of the order of a cm. The measurement of profil… more
Date: August 1, 1981
Creator: Jacobsen, R.A.
Partner: UNT Libraries Government Documents Department
open access

Resistive demountable toroidal-field coils for tokamak reactors

Description: Readily demountable TF (toroidal-field) coils allow complete access to the internal components of a tokamak reactor for maintenance of replacement. The requirement of readily demountable joints dictates the use of water-cooled resistive coils, which have a host of decisive advantages over superconducting coils. Previous papers have shown that resistive TF coils for tokamak reactors can operate in the steady state with acceptable power dissipation (typically, 175 to 300 MW). This paper summarize… more
Date: July 1, 1981
Creator: Jassby, D. L.; Jacobsen, R. A.; Kalnavarns, J.; Masson, L. S. & Sekot, J. P.