8 Matching Results

Search Results

Advanced search parameters have been applied.

Hanford Single-Shell Tank Leak Causes and Locations - 241-A Farm

Description: This document identifies 241-A Tank Farm (A Farm) leak causes and locations for the 100 series leaking tanks (241-A-104 and 241-A-105) identified in RPP-ENV-37956, Hanford A and AX Farm Leak Assessment Report. This document satisfies the A Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: September 10, 2013
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

Hanford Single-Shell Tank Leak Causes and Locations - 241-B Farm

Description: This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: July 11, 2013
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

Hanford Single-Shell Tank Leak Causes and Locations - 241-C Farm

Description: This document identifies 241-C Tank Farm (C Farm) leak causes and locations for the 100 series leaking tanks (241-C-101 and 241-C-105) identified in RPP-RPT-33418, Rev. 2, Hanford C-Farm Leak Inventory Assessments Report. This document satisfies the C Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: July 30, 2013
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

241-AZ Farm Annulus Extent of Condition Baseline Inspection

Description: This report provides the results of the comprehensive annulus visual inspection for tanks 241- AZ-101 and 241-AZ-102 performed in fiscal year 2013. The inspection established a baseline covering about 95 percent of the annulus floor for comparison with future inspections. Any changes in the condition are also included in this document.
Date: May 15, 2013
Creator: Engeman, Jason K.; Girardot, Crystal L. & Vazquez, Brandon J.
Partner: UNT Libraries Government Documents Department

Hanford Single-Shell Tank Leak Causes and Locations - 241-SX Farm

Description: This document identifies 241-SX Tank Farm (SX Farm) leak causes and locations for the 100 series leaking tanks (241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114, and 241-SX-115) identified in RPP-ENV-39658, Rev. 0, Hanford SX-Farm Leak Assessments Report. This document satisfies the SX Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: January 8, 2014
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

Description: This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) leak causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105, and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: November 19, 2013
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

Hanford Single-Shell Tank Leak Causes and Locations - 241-U Farm

Description: This document identifies 241-U Tank Farm (U Farm) leak causes and locations for the 100 series leaking tanks (241-U-104, 241-U-110, and 241-U-112) identified in RPP-RPT-50097, Rev. 0, Hanford 241-U Farm Leak Inventory Assessment Report. This document satisfies the U-Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Date: December 2, 2013
Creator: Girardot, Crystal L. & Harlow, Donald G.
Partner: UNT Libraries Government Documents Department

Double-Shell Tank Visual Inspection Changes REsulting from the Tank 241-AY-102 Primary Tank Leak - 14193

Description: As part of the Double-Shell Tank (DST) Integrity Program, remote visual inspections are utilized to perform qualitative in-service inspections of the DSTs in order to provide a general overview of the condition of the tanks. During routine visual inspections of tank 241-AY -1 02 (A Y -1 02) in August 2012, anomalies were identified on the annulus floor which resulted in further evaluations. In October 2012, Washington River Protection Solutions, LLC determined that the primary tank of AY -102 was leaking. Following identification of the tank AY-102 probable leak cause, evaluations considered the adequacy of the existing annulus inspection frequency with respect to the circumstances of the tank AY-1021eak and the advancing age of the DST structures. The evaluations concluded that the interval between annulus inspections should be shortened for all DSTs, and each annulus inspection should cover > 95 percent of annulus floor area, and the portion of the primary tank (i.e., dome, sidewall, lower knuckle, and insulating refractory) that is visible from the annulus inspection risers. In March 2013, enhanced visual inspections were performed for the six oldest tanks: 241-AY-101, 241-AZ-101,241-AZ-102, 241-SY-101, 241-SY-102, and 241-SY-103, and no evidence of leakage from the primary tank were observed. Prior to October 2012, the approach for conducting visual examinations of DSTs was to perform a video examination of each tank's interior and annulus regions approximately every five years (not to exceed seven years between inspections). Also, the annulus inspection only covered about 42 percent of the annulus floor.
Date: November 14, 2013
Creator: Girardot, Crystal L.; Washenfelder, Dennis J.; Johnson, Jeremy M. & Engeman, Jason K.
Partner: UNT Libraries Government Documents Department