Advanced Emissions Control Development Program

Description: Babcock & Wilcox (B&W) is conducting a five-year project aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (commonly called air toxics) from coal-fired electric utility plants. The need for air toxic emissions controls may arise as the U. S. Environmental Protection Agency proceeds with implementation of Title III of the Clean Air Act Amendment (CAAA) of 1990. Data generated during the program will provide utilities with the technical and economic information necessary to reliably evaluate various air toxics emissions compliance options such as fuel switching, coal cleaning, and flue gas treatment. The development work is being carried out using B&W�s new Clean Environment Development Facility (CEDF) wherein air toxics emissions control strategies can be developed under controlled conditions, and with proven predictability to commercial systems. Tests conducted in the CEDF provide high quality, repeatable, comparable data over a wide range of coal properties, operating conditions, and emissions control systems. Development work to date has concentrated on the capture of mercury, other trace metals, fine particulate, and the inorganic species hydrogen chloride and hydrogen fluoride.
Date: December 3, 1998
Creator: Evans, A. P.
Partner: UNT Libraries Government Documents Department

Advanced Emissions Control Development Program

Description: McDermott Technology, Inc. (MTI) is conducting a five-year project aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (commonly called air toxics) from coal-fired electric utility plants. The need for air toxic emissions controls may arise as the U. S. Environmental Protection Agency proceeds with implementation of Title III of the Clean Air Act Amendment (CAAA) of 1990. Data generated during the program will provide utilities with the technical and economic information necessary to reliably evaluate various air toxics emissions compliance options such as fuel switching, coal cleaning, and flue gas treatment. The development work is being carried out using the Clean Environment Development Facility (CEDF) wherein air toxics emissions control strategies can be developed under controlled conditions, and with proven predictability to commercial systems. Tests conducted in the CEDF provide high quality, repeatable, comparable data over a wide range of coal properties, operating conditions, and emissions control systems. Development work to date has concentrated on the capture of mercury, other trace metals, fine particulate, and the inorganic species, hydrogen chloride and hydrogen fluoride.
Date: December 3, 1998
Creator: Evans, A. P.
Partner: UNT Libraries Government Documents Department

Advanced emissions control development program. Quarterly technical progress report No. 9, October 1--December 31, 1996

Description: Babcock & Wilcox (B&W) is conducting a five-year project aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (commonly called air toxics) from coal-fired electric utility plants. The need for air toxic emissions controls may arise as the U.S. Environmental Protection Agency proceeds with implementation of Title III of the Clean Air Act Amendment of 1990. Data generated during the program will provide utilities with the technical and economic information necessary to reliably evaluate various air toxics emission compliance options such as fuel switching, coal cleaning, and flue gas treatment. The development work is being carried out using B&W`s new Clean Environment Development Facility (CEDF) wherein air toxics emission control strategies can be developed under controlled conditions, and with proven predictability to commercial systems. Tests conducted in the CEDF provide high quality, repeatable, comparable data over a wide range of coal properties, operating conditions, and emissions control systems. Development work to date has concentrated on the capture of mercury, other trace metals, fine particulate, and the inorganic species hydrogen chloride and hydrogen fluoride.
Date: December 31, 1996
Creator: Evans, A.P.
Partner: UNT Libraries Government Documents Department

Advanced Emission Control Development Program.

Description: Babcock & Wilcox (B&W) is conducting a five-year project aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (commonly called air toxics) from coal-fired electric utility plants. The need for air toxic emissions controls may arise as the U. S. Environmental Protection Agency proceeds with implementation of Title III of the Clean Air Act Amendment (CAAA) of 1990. Data generated during the program will provide utilities with the technical and economic information necessary to reliably evaluate various air toxics emissions compliance options such as fuel switching, coal cleaning, and flue gas treatment. The development work is being carried out using B&W`s new Clean Environment Development Facility (CEDF) wherein air toxics emissions control strategies can be developed under controlled conditions, and with proven predictability to commercial systems. Tests conducted in the CEDF provide high quality, repeatable, comparable data over a wide range of coal properties, operating conditions, and emissions control systems. Development work to date has concentrated on the capture of mercury, other trace metals, fine particulate, and the inorganic species hydrogen chloride and hydrogen fluoride.
Date: December 31, 1997
Creator: Evans, A.P.
Partner: UNT Libraries Government Documents Department

Advanced emissions control development program. Quarterly technical progress report {number_sign}8, July 1--September 30, 1996

Description: The objective of this project is to develop practical strategies and systems for the simultaneous control of SO{sub 2}, NO{sub x}, particulate matter, and air toxics emissions from coal-fired boilers in such a way as to keep coal economically and environmentally competitive as a utility boiler fuel. Of particular interest is the control of air toxics emissions through the cost-effective use of conventional flue gas clean-up equipment such as electrostatic precipitators (ESP`s), fabric filters (baghouses), and SO{sub 2} removal systems such as wet scrubbers and various clean coal technologies. This objective will be achieved through extensive development testing in Babcock and Wilcox`s state-of-the-art, 10 MW{sub e} equivalent, Clean Environment Development Facility (CEDF). The project has extended the capabilities of the CEDF to facilitate air toxics emissions control development work on backend flue gas cleanup equipment. Specifically, an ESP, a baghouse, and a wet scrubber for SO{sub 2} (and air toxics) control were added--all designed to yield air toxics emissions data under controlled conditions, and with proven predictability to commercial systems. The specific objectives of the project are to: measure and understand production and partitioning of air toxics species in coal-fired power plant systems; optimize the air toxics removal performance of conventional flue gas cleanup systems; quantify the impacts of coal cleaning on air toxics emissions; identify and/or develop advanced air toxics emissions control concepts; develop and validate air toxics emissions measurement and monitoring techniques; and establish an air toxics data library to facilitate studies of the impacts of coal selection, coal cleaning, and emissions control strategies on the emissions of coal-fired power plants.
Date: December 31, 1996
Creator: Evans, A.P.
Partner: UNT Libraries Government Documents Department

Mercury speciation measurements on a 10 MW{sub e} coal-fired boiler simulator

Description: The current trends towards deregulation of electric utilities, air toxic regulations and stringent fine particulate emissions reflect an increased need for coal-based research. In response, Babcock and Wilcox invested in the state-of-the-art 100 million Btu/hr (10 MW, equivalent) Clean Environment Development Facility (CEDF) located in Alliance, Ohio. The representative combustion conditions, flow patterns and residence times permit direct scale-up of CEDF test results to commercial boilers and pollution control devices. In cooperation with the U.S. Department of Energy and the Ohio Coal Development Office within the Ohio Office of Development, B&W is employing the CEDF to conduct a five-year project aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants from coal-fired boilers. The project specifically targets the control of mercury, the trace element under close scrutiny by the EPA. Due to the various forms of mercury emissions from coal-fired boilers, accurate mercury speciation measurements are required to develop mercury control strategies. Current uncertainty in the accuracy and mercury speciation capability of mercury sampling methods led B&W to use both EPA Method 29 and the Ontario Hydro procedures to measure mercury emissions from CEDF pollution control devices. A comparison of the speciated mercury emissions is presented.
Date: June 1, 1997
Creator: Evans, A.P. & Nevitt, K.D.
Partner: UNT Libraries Government Documents Department

Advanced Emissions Control Development Program: Mercury Control

Description: McDermott Technology, Inc. (a subsidiary of Babcock & Wilcox) is conducting the Advanced Emissions Control Development Project (AECDP) which is aimed at the development of practical, cost-effective strategies for reducing the emissions of hazardous air pollutants (HAPS) from coal-fired electric utility plants. The need for such controls may arise as the US Environmental Protection Agency (EPA) proceeds with implementation of requirements set forth in the Clean Air Act Amendments (CAAA`s) of 1990. Promulgation of air toxics emissions regulations for electric utility plants could dramatically impact utilities burning coal, their industrial and residential customers, and the coal industry. AECDP project work will supply the information needed by utilities to respond to potential HAPs regulations in a timely, cost-effective, enviromnentally-sound manner which supports the continued use of the Nation`s abundant reserves of coal, such as those in the State of Ohio. The development work is being carried out using the 10 MW Clean Environment Development Facility wherein air toxics emissions control strategies can be developed under controlled conditions. The specific objectives of the project are to (1) measure and understand production and partitioning of air toxics species for a variety of coals, (2) optimize the air toxics removal performance of conventional flue gas cleanup systems, (3) develop advanced air toxics emissions control concepts, (4) develop and validate air toxics emissions measurement and monitoring techniques, and (5) establish a comprehensive, self-consistent air toxics data library. This project is supported by the Department of Energy, the Ohio Coal Development Office within the Ohio Department of Development and Babcock & Wilcox. A comprehensive assessment of HAP emissions from coal-fired electric utility boilers sponsored by the Department of Energy and the Electric Power Research Institute concluded that with the exception of selenium and mercury, the majority of trace elements are well controlled due to their association ...
Date: July 1, 1997
Creator: Evans, A. P.; Redinger, K. W. & Holmes, M. J.
Partner: UNT Libraries Government Documents Department

Advanced emissions control development program: Phase 2 final report, February 29, 1996--August 31, 1997. Revision 1

Description: The objective of the advanced emissions control development program (AECDP) is to develop practical, cost-effective strategies for reducing the emissions of air toxics from coal-fired boilers. Ideally, the project aim is to effectively control air toxic emissions through the use of conventional flue gas cleanup equipment such as electrostatic precipitators (ESPs), fabric filters (baghouse), and wet flue gas desulfurization. Development work to date has concentrated on the capture of mercury, other trace metals [antimony, arsenic, barium, cadmium, chromium, cobalt, lead, manganese, nickel, and selenium], fine particulate and hydrogen chloride. Some general comments that can be made about the control of air toxics while burning a high-sulfur bituminous coal are as follows: (1) particulate control devices such as ESP`s and baghouses do a good job of removing non-volatile trace metals; (2) mercury goes through particulate control devices almost entirely uncontrolled; (3) wet scrubbing can effectively remove hydrogen chloride; and (4) wet scrubbers show good potential for the removal of mercury when operated under certain conditions, however additional work is needed to understand the relationship between the wet scrubber`s operating conditions and mercury capture.
Date: April 1, 1998
Creator: Evans, A. P.; Holmes, M. J. & Redinger, K. E.
Partner: UNT Libraries Government Documents Department