Water testing of the inducer pump. [LMFBR]
Description:
The inducer pump, designed and fabricated as a test article to evaluate the inducer/impeller pump concept for providing improved suction performance of large sodium pumps, met or exceeded all performance goals. The inducer stage in front of the centrifugal impeller dramatically reduces the size of pumps. It was demonstrated that the inducer can operate at suction specific speeds in excess of 35,000, whereas conventional centrifugal pumps have demonstrated capability to only 12,000. The inducer …
more
Date:
September 15, 1977
Creator:
Dunn, C. & Hoshide, R.K.