Test plan for anion exchange testing with Argonne 10-L solutions

Description: The purpose of this test plan is to determine the performance characteristics of four anion exchange resins. This information is required to scale up an ion exchange process for removing undesirable chemicals from calciner feed at PFP. The performance characteristics will be judged by comparing the total exchange capacity, the sorption and desorption of plutonium, the distribution coefficient, and other operating information in the presence of various complexing anions. The results will be comp… more
Date: May 10, 1995
Creator: Compton, J. A.
Partner: UNT Libraries Government Documents Department
open access

Comparison of deliverable and exhaustible pressurized air flow rates in laboratory gloveboxes

Description: Calculations were performed to estimate the maximum credible flow rates of pressurized air into Plutonium Process Support Laboratories gloveboxes. Classical equations for compressible fluids were used to estimate the flow rates. The calculated maxima were compared to another`s estimates of glovebox exhaust flow rates and corresponding glovebox internal pressures. No credible pressurized air flow rate will pressurize a glovebox beyond normal operating limits. Unrestricted use of the pressurized … more
Date: October 1, 1994
Creator: Compton, J. A.
Partner: UNT Libraries Government Documents Department
open access

Test procedure for anion exchange testing with Argonne 10-L solutions

Description: Four anion exchange resins will be tested to confirm that they will sorb and release plutonium from/to the appropriate solutions in the presence of other cations. Certain cations need to be removed from the test solutions to minimize adverse behavior in other processing equipment. The ion exchange resins will be tested using old laboratory solutions from Argonne National Laboratory; results will be compared to results from other similar processes for application to all plutonium solutions store… more
Date: May 17, 1995
Creator: Compton, J. A.
Partner: UNT Libraries Government Documents Department
open access

Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner

Description: Stored solutions containing plutonium and nitric acid and possibly uranium thorium and minor amounts of other substances will be used for development and demonstration of a vertical calciner direct denitration process for conversion of those to stable storable PuO{sub 2} rich solids. Some of those solutions are quite dilute and very impure these require either pretreatment to make them suitable for calciner feed or an alternate stabilization method. Untreated scrap solutions containing some amo… more
Date: February 3, 2000
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Time and Temperature Test Results for PFP Thermal Stabilization Furnaces

Description: The national standard for plutonium storage acceptability (standard DOE-STD-3013-99, generally known as ''the 3013 standard'') has been revised to clarify the requirement for processes that will produce acceptable storage materials. The 3013 standard (Reference 1) now states that ''Oxides shall be stabilized by heating the material in an oxidizing atmosphere to a Material Temperature of at least 950 C (1742 F) for not less than 2 hours.'' The process currently in use for producing stable oxides… more
Date: August 9, 2000
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Test plan for radioactive testing of a vertical direct denitration calciner

Description: The prototype Vertical Denitration Calciner (VDC) is installed in glovebox 188 in the Plutonium Process Support Laboratory (PPSL). Safety analysis contained in WHC-SD-CP-SAR-021 (FSAR) Rev. 0-L and Addendum to WHC-SD-CP-SAR-021, ''Laboratory Prototype Calciner'' establishes the prototype VDC needs to be shut down if a seismic event of greater than 0.07 g occurs. Shut down is to be automatic upon detection of the seismic event. This requires tie-in of various valves and power for the prototype V… more
Date: August 31, 1999
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner

Description: The prototype Vertical Denitration Calciner (VDC) is installed in glovebox 188 in the Plutonium Process Support Laboratory (PPSL). Safety analysis contained in WHC-SD-CP-SAR-021 (FSAR) Rev. 0-L and Addendum to WHC-SD-CP-SAR-021, ''Laboratory Prototype Calciner'' establishes the prototype VDC needs to be shut down if a seismic event of greater than 0.07 g occurs. Shut down is to be automatic upon detection of the seismic event. This requires tie-in of various valves and power for the prototype V… more
Date: August 31, 1999
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner

Description: Stored solutions containing plutonium and nitric acid and possibly uranium thorium and minor amounts of other substances will be used for development and demonstration of a vertical calciner direct denitration process for conversion of those to stable storable PuO{sub 2} rich solids. Some of those solutions are quite dilute and very impure these require either pretreatment to make them suitable for calciner feed or an alternate stabilization method. Untreated scrap solutions containing some amo… more
Date: February 3, 2000
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner

Description: A vertical calciner will be used to demonstrate the direct denitration process for converting plutonium-bearing liquors to stable plutonium rich solids. The calciner and some of its associated equipment were previously tested with non-radioactive chemicals to demonstrate operability.
Date: October 5, 1999
Creator: Compton, J. A.
Partner: UNT Libraries Government Documents Department
open access

Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner

Description: The prototype Vertical Denitration Calciner (VDC) is installed in glovebox 188 in the Plutonium Process Support Laboratory (PPSL). Safety analysis contained in WHC-SD-CP-SAR-021 (FSAR) Rev. 0-L and Addendum to WHC-SD-CP-SAR-021, ''Laboratory Prototype Calciner'' establishes the prototype VDC needs to be shut down if a seismic event of greater than 0.07 g occurs. Shut down is to be automatic upon detection of the seismic event. This requires tie-in of various valves and power for the prototype V… more
Date: August 13, 1999
Creator: COMPTON, J.A.
Partner: UNT Libraries Government Documents Department
open access

Moisture absorption results for vertical calciner plutonium dioxide product

Description: A sample of calcined plutonium dioxide was exposed to room air for one week. The sample was weighed daily to determine if the material absorbed moisture from the room air. A random variation of weight was observed after the first day; however, the sample returned to its original weight at the end of the week. The loss on ignition for the material increased from 0.439 to 0.544 weight percent during this time. This change is considered inconsequential as the material will normally be packaged for… more
Date: July 3, 1996
Creator: Compton, J.A., Westinghouse Hanford
Partner: UNT Libraries Government Documents Department