3 Matching Results

Search Results

Advanced search parameters have been applied.

ARG portable neutron radiography. Final report

Description: In this report all available neutron radiographic data, including results of tests run at LANL, McClellan AFB, and University of Virginia, will be combined to outline specific transportable neutron radiography systems that could achieve the desired results as a complement to x-radiography capabilities for the Accident Response Group (ARG).
Date: April 1, 1995
Creator: Barton, J.P.
Partner: UNT Libraries Government Documents Department

High frame-rate neutron radiography of dynamic events

Description: A system has been developed to perform neutron radiographic analysis of dynamic events having a duration of several milliseconds. The system has been operated in the range of 2000 to 10,000 frames/second. Synchronization has provided high-speed-motion neutron radiographs for evaluation of the firing cycle of 7.62 mm munition rounds within a steel rifle barrel. The system has also been used to demonstrate the ability to produce neutron radiographic movies of two-phase flow. The equipment uses the Oregon State University TRIGA reactor capable of pulsing to 3000 MW peak power, a neutron beam collimator, a scintillator neutron conversion screen coupled to an image intensifier, and a 16 mm high speed movie camera. The peak neutron flux incident at the object position is approximately 4 x 10/sup 11/ n/cm/sup 2/s with a pulse, full width at half maximum, of 9 ms. Special studies have been performed on the scintillator conversion screens and on the effects of statistical limitations on the image quality. Modulation transfer function analysis has been used to assist in the evaluation of the system performance.
Date: November 20, 1981
Creator: Bossi, R.H.; Robinson, A.H. & Barton, J.P.
Partner: UNT Libraries Government Documents Department

Multi-purpose neutron radiography system

Description: A conceptual design is given for a low cost, multipurpose radiography system suited for the needs of the Los Alamos National Laboratory (LANL). The proposed neutron source is californium-252. One purpose is to provide an in-house capability for occasional, reactor quality, neutron radiography thus replacing the recently closed Omega-West Reactor. A second purpose is to provide a highly reliable standby transportable neutron radiography system. A third purpose is to provide for transportable neutron probe gamma spectroscopy techniques. The cost is minimized by shared use of an existing x-ray facility, and by use of an existing transport cask. The achievable neutron radiography and radioscopy performance characteristics have been verified. The demonstrated image qualities range from high resolution gadolinium - SR film, with L:D = 100:1, to radioscopy using a LIXI image with L:D = 30:1 and neutron fluence 3.4 x 10{sup 5} n/cm{sup 2}.
Date: July 1, 1996
Creator: Barton, J.P.; Bryant, L.E. & Berry, P.
Partner: UNT Libraries Government Documents Department