Search Results

Advanced search parameters have been applied.
open access

Urban Waste Grease Resource Assessment

Description: This study collected and analyzed data on urban waste grease resources in 30 randomly selected metropolitan areas in the United States. Two major categories (yellow grease feedstock collected from restaurants by rendering companies; and grease trap wastes from restaurants, which can either be pumped into tank trucks for disposal or flow through municipal sewage systems into wastewater treatment plants) were considered in this study.
Date: March 17, 1999
Creator: Wiltsee, G.
Partner: UNT Libraries Government Documents Department
open access

Cold Vacuum Drying facility potable water system design description (SYS 26)

Description: This document describes the Cold Vacuum Drying Facility (CVDF) potable water (PW) system. The PW system provides potable water to the CVDF for supply to sinks, water closets, urinals, showers, custodial service sinks, drinking fountains, the decontamination shower, supply water to the non-PW systems, and makeup water for the de-ionized water system.
Date: July 2, 1999
Creator: PITKOFF, C.C.
Partner: UNT Libraries Government Documents Department
open access

Classification of the MGR Pool Water Treatment and Cooling System

Description: The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) pool water treatment and cooling system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998).
Date: August 31, 1999
Creator: Ziegler, J. A.
Partner: UNT Libraries Government Documents Department
open access

Ion Exchange Conceptual Design for Treating Seven Technical Area Sumps with Elevated Levels of Copper and Zinc

Description: Recently a meeting was held to discuss technical support for developing a conceptual design and estimate for installing and operating an in-line ion exchange system to treat seven Technical Area Sumps with elevated levels (high ppb - low ppm) of copper and potentially zinc (copper level is above the outfall limits). These sump waters are currently routed to the A01 outfall, which is permitted by the State of South Carolina. a study of potential treatment options and followup laboratory work don… more
Date: February 17, 1999
Creator: Oji, L.N.
Partner: UNT Libraries Government Documents Department
open access

Record of Technical Change {number_sign}1 for ''Corrective Action Investigation Plan for Corrective Action Unit 406: Area 3 Building 03-74 and Building 03-58 Underground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 and Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada'' Revision 0

Description: This Record of Technical Change provides updates to the technical information included in ''Corrective Action Investigation Plan for Corrective Action Unit 406: Area 3 Building 03-74 and Building 03-58 Underground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 and Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada'' Revision 0
Date: June 30, 1999
Creator: Office, US DOE Nevada Operations
Partner: UNT Libraries Government Documents Department
open access

Record of Technical Change {number_sign}1 for Corrective Action Investigation Plan for Corrective Action Unit 500: Test Cell A Septic System, Nevada Test Site, Nevada, Revision 0

Description: This Record of Technical Change provides updates to the technical information in ''Corrective Action Investigation Plan for Corrective Action Unit 500: Test Cell A Septic System, Nevada Test Site, Nevada,'' DOE/NV--528.
Date: April 12, 1999
Creator: Office, US DOE Nevada Operations
Partner: UNT Libraries Government Documents Department
open access

Risk management program for the 283-W water treatment facility

Description: This Risk Management (RM) Program covers the 283-W Water Treatment Facility (283W Facility), located in the 200 West Area of the Hanford Site. A RM Program is necessary for this facility because it stores chlorine, a listed substance, in excess of or has the potential to exceed the threshold quantities defined in Title 40 of the Code of Federal Regulations (CFR) Part 68 (EPA, 1998). The RM Program contains data that will be used to prepare a RM Plan, which is required by 40 CFR 68. The RM Plan … more
Date: May 11, 1999
Creator: Green, W. E.
Partner: UNT Libraries Government Documents Department
open access

Criticality safety evaluation report for the cold vacuum drying facility's process water handling system

Description: This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified.
Date: May 12, 1999
Creator: NELSON, J.V.
Partner: UNT Libraries Government Documents Department
open access

Deployment support leading to implementation

Description: This quarterly report discusses progress on the following tasks and subtasks: (Task 1)--Field demonstration of prefabricated vertical drains (PVD) technology: Subtask 1.1--Pilot scale demonstration of TCE flushing through PVDs at the DOE/RMI Extrusion Plant; Subtask 1.2--Technical support on surfactants and QA/QC for field operations employing PVDs at the RMI Ashtabula, Ohio, site; Subtask 1.3--Operational support of the PVDs and engineering/design/construction/operations of a wastewater treatm… more
Date: November 1, 1999
Partner: UNT Libraries Government Documents Department
open access

Results of Tritium Tracking and Groundwater Monitoring at the Hanford Site 200 Area State-Approved Land Disposal Site-FY1999

Description: The Hanford Site 200 Area Effluent Treatment Facility (ETF) processes contaminated liquids derived from Hanford Site facilities. The clean water generated by these processes is occasionally enriched in tritium and is discharged to the 200 Area State Approved Land Disposal Site (SALDS). Groundwater monitoring for tritium and other constituents is required by the state-issued permit at 21 wells surrounding the facility. During FY 1999, average tritium activities in most wells declined from averag… more
Date: October 20, 1999
Creator: Barnett, D. B.
Partner: UNT Libraries Government Documents Department
open access

Environmental Assessment and Finding of No Significant Impact: Wastewater Treatment Capability Upgrade, Project NO. 96-D-122 Pantex Plant Amarillo, Texas

Description: This Environmental Assessment (EA) addresses the U.S. Department of Energy (DOE) proposed action regarding an upgrade of the Pantex Plant Wastewater Treatment Facility (WWTF). Potential environmental consequences associated with the proposed action and alternative actions are provided. DOE proposes to design, build, and operate a new WWTF, consistent with the requirements of Title 30 of the Texas Administrative Code (TAC), Chapter 317, ''Design Criteria for Sewage Systems,'' capable of supporti… more
Date: May 27, 1999
Partner: UNT Libraries Government Documents Department
open access

LIQUID NATURAL GAS (LNG): AN ALTERNATIVE FUEL FROM LANDFILL GAS (LFG) AND WASTEWATER DIGESTER GAS

Description: This Research and Development Subcontract sought to find economic, technical and policy links between methane recovery at landfill and wastewater treatment sites in New York and Maryland, and ways to use that methane as an alternative fuel--compressed natural gas (CNG) or liquid natural gas (LNG) -- in centrally fueled Alternative Fueled Vehicles (AFVs).
Date: March 1, 1999
Creator: Vandor, D.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen