High SO{sub 2} removal efficiency testing. Quarterly report, July - September 1996

Description: This document provides a discussion of the technical progress on DOE/PETC project number DE-AC22-92PC91338, ``High Efficiency SO{sub 2} Removal Testing,`` for the time period 1 July through 30 September 1996. The project involves testing at six full-scale utility flue gas desulfurization (FGD) systems, to evaluate low capital cost upgrades that may allow these systems to achieve up to 98% SO{sub 2} removal efficiency. The upgrades being evaluated mostly involve using performance additives in th… more
Date: July 1, 1996
Creator: Blythe, G.
Partner: UNT Libraries Government Documents Department
open access

High SO{sub 2} removal efficiency testing. Quarterly status report, April-June 1995

Description: This project involves testing at six full-scale utility flue gas desulfurization (FGD) systems to evaluate low capital cost upgrades that may allow these systems to achieve up to 98% SO{sub 2} removal efficiency. The upgrades being evaluated mostly involve using performance additives in the FGD systems. The {open_quotes}base{close_quotes} project involved testing at the Tampa Electric Company Big Bend station. All five potential options to the base program have been exercised by DOE, involving … more
Date: July 14, 1995
Creator: Blythe, G.
Partner: UNT Libraries Government Documents Department