Search Results

Advanced search parameters have been applied.
open access

Laboratory Investigations in Support of Carbon Dioxide-Limestone Sequestration in the Ocean

Description: This semi-annual progress reports includes further findings on CO{sub 2}-in-Water emulsions stabilized by fine particles of limestone (CaCO{sub 3}). Specifically, here we report on the tests performed in the DOE National Energy Technology Laboratory High Pressure Water Tunnel Facility (HPWTF) using a Kenics-type static mixer for the formation of a CO{sub 2}-H{sub 2}O emulsion stabilized by fine particles of CaCO{sub 3}. The tested static mixer has an ID of 0.5 cm, length 23.5 cm, number of baff… more
Date: April 1, 2006
Creator: Golomb, Dan; Barry, Eugene; Ryan, David; Pennell, Stephen; Swett, Peter; Duan, Huishan et al.
Partner: UNT Libraries Government Documents Department
open access

Slurry Pump Mixing Effectiveness in Tank 50h

Description: Computational Fluid Dynamics (CFD) models of Tank 50 with different numbers of pumps and operational modes, including pump rotation, have been developed to estimate flow patterns and the resultant sludge mixing. Major solid obstructions including the tank wall, the pump housing, the pump columns, and the 82-in central support column were included in the model. Transient analyses with a two-equation turbulence model were performed with FLUENT{trademark}, a commercial CFD code. All analyses were … more
Date: April 15, 2008
Creator: Lee, S. & Richard Dimenna, R.
Partner: UNT Libraries Government Documents Department
open access

Mathematical modeling of mixer pump performance for agitation of radioactive slurries in one-million-gallon underground storage tanks at Hanford

Description: The objective of this work is to analyze the Hanford Waste Vitrification Project (HWVP) feed preparation tank mixing pump agitation design. This was accomplished by (1) reviewing mixing pump characteristics, (2) performing computer modeling of jet mixing and particulate material transport, (3) evaluating the propensity of the tank and mixing pump design to maintain particulate material in the tank in a uniformly mixed state, and (4) identifying important design parameters required to ensure opt… more
Date: April 1, 1993
Creator: Bamberger, J. A.; Eyler, L. L. & Dodge, R. E.
Partner: UNT Libraries Government Documents Department
open access

PROPERTIES IMPORTANT TO MIXING FOR WTP LARGE SCALE INTEGRATED TESTING

Description: Large Scale Integrated Testing (LSIT) is being planned by Bechtel National, Inc. to address uncertainties in the full scale mixing performance of the Hanford Waste Treatment and Immobilization Plant (WTP). Testing will use simulated waste rather than actual Hanford waste. Therefore, the use of suitable simulants is critical to achieving the goals of the test program. External review boards have raised questions regarding the overall representativeness of simulants used in previous mixing tests.… more
Date: April 26, 2012
Creator: Koopman, D.; Martino, C. & Poirier, M.
Partner: UNT Libraries Government Documents Department
open access

Estimate of the Distribution of Solids Within Mixed Hanford Double-Shell Tank AZ-101: Implications for AY-102

Description: This paper describes the current level of understanding of the suspension of solids in Hanford double-shell waste tanks while being mixed with the baseline configuration of two 300-horsepower mixer pumps. A mixer pump test conducted in Tank AZ-101 during fiscal year 2000 provided the basis for this understanding. Information gaps must be filled to demonstrate the capability of the baseline feed delivery system to effectively mix, sample, and deliver double-shell tank waste to the Hanford Tank W… more
Date: April 29, 2009
Creator: Wells, Beric E. & Ressler, Jennifer J.
Partner: UNT Libraries Government Documents Department
open access

The Role of Cohesive Particle Interactions on Solids Uniformity and Mobilization During Jet Mixing: Testing Recommendations

Description: Radioactive waste that is currently stored in large underground tanks at the Hanford Site will be staged in selected double-shell tanks (DSTs) and then transferred to the Waste Treatment and Immobilization Plant (WTP). Before being transferred, the waste will be mixed, sampled, and characterized to determine if the waste composition and meets the waste feed specifications. Washington River Protection Solutions is conducting a Tank Mixing and Sampling Demonstration Program to determine the mixin… more
Date: April 1, 2010
Creator: Gauglitz, Phillip A.; Wells, Beric E.; Bamberger, Judith A.; Fort, James A.; Chun, Jaehun & Jenks, Jeromy WJ
Partner: UNT Libraries Government Documents Department
open access

CST Suspension Analysis for Slurry Pumps of Tank 40

Description: Tank 40 simulation models with four submersible slurry pumps available for the CST suspension operations have been developed to provide operational guidance of slurry pumps for an efficient sludge removal. A series of the modeling calculations have been performed for key operational parameters such as pump operation mode, number of operating pumps, and to provide a recommendation for CST suspension and mixing operations in Tank 40. Reference design and operating conditions shown in Table 1 were… more
Date: April 1, 2004
Creator: LEE, SIY.
Partner: UNT Libraries Government Documents Department
open access

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

Description: This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be… more
Date: April 10, 2000
Creator: TEMPLETON, A.M.
Partner: UNT Libraries Government Documents Department
open access

234-5 Building RM line equipment tests, Task III mixer

Description: Several operations that are important to the process as carried out in Task III (Reduction) are performed by the mixer. In order to specify the process certain tests were made to study these operations and are discussed in this report. They include: Mixing Time, Mixer Discharge Rate, Mixer Holdup, and Mixer Capacity. A description of the test, conclusions and recommendations is provided.
Date: April 10, 1952
Creator: Collins, P. E.
Partner: UNT Libraries Government Documents Department
open access

Performance Analysis for Mixing Pumps in Tank 18

Description: In support of sludge suspension and mixing operations in Tank 18, flow evolution models were developed and performance calculations completed for the advanced design mixer pump (ADMP) and the modified ADMP (MADMP). The MADMP was being considered as a replacement for the ADMP in Tank 18. The models and calculations were based on prototypic tank geometry and expected normal operating conditions as defined by Waste Removal Closure (WRC) Engineering. Computational fluid dynamics models of both the … more
Date: April 16, 2002
Creator: Lee, Si Young
Partner: UNT Libraries Government Documents Department
open access

Nonradioactive Environmental Emissions Chemical Source Term for the Double Shell Tank (DST) Vapor Space During Waste Retrieval Operations

Description: A nonradioactive chemical vapor space source term for tanks on the Phase 1 and the extended Phase 1 delivery, storage, and disposal mission was determined. Operations modeled included mixer pump operation and DST waste transfers. Concentrations of ammonia, specific volatile organic compounds, and quantitative volumes of aerosols were estimated.
Date: April 21, 2000
Creator: MAY, T.H.
Partner: UNT Libraries Government Documents Department
open access

Three-Dimensional CFD FLYGT Mixer Model and Results

Description: The main objectives of the present work are to examine detailed flow performance of the Tank 19 FLYGT mixer improved by the previous work, to conduct sensitivity analysis for a wide range of possible boundary conditions, and to investigate transient flow behavior and loading of the FLYGT mixer. For the present study, a flow simulation method is developed to calculate the flow around a marine-type propeller configuration of the FLYGT mixer.
Date: April 16, 2002
Creator: Lee, S. Y.
Partner: UNT Libraries Government Documents Department
open access

TNX/HLW Long Shaft Pumps 1995-2000

Description: Problems with long shaft pumps are becoming clearer due to increased use, better instrumentation, more analysis, and increased testing activity. The problems are with reliability and not with hydraulic performance. The root cause of reliability problems is usually excessive vibration caused by design. The outlook for satisfactory pumps is improved as understanding of problems increases. Promising developments are emerging such as the tilt pad bearing. Alternative configurations, such as gas fil… more
Date: April 3, 2002
Creator: VanPelt, B.
Partner: UNT Libraries Government Documents Department
captions transcript

[News Clip: Truck]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about a concrete truck overturning in Fort Worth.
Date: April 4, 1961
Duration: 58 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
open access

The Potential for Buoyant Displacement Gas Release Events in Tank 241-SY-102 after Waste Transfer from Tank 241-SY-101

Description: Tank 241-SY-101 is a double-shell radioactive waste storage tank containing waste that, before recent transfer and water back-dilution operations, was capable of retaining gas and producing flammable buoyant displacement gas release events (BD GREs). A BD GRE occurs when a portion of the nonconvective layer waste retains enough gas to become buoyant, rises to the waste surface, breaks up, and releases some of the stored gas. Installing the mixer pump in 1993 successfully mitigated gas retention… more
Date: April 10, 2000
Creator: Wells, Beric E.; Meyer, Perry A. & Chen, Guang
Partner: UNT Libraries Government Documents Department
open access

Gas-mixing system for drift chambers using solenoid valves

Description: We describe an inexpensive system for mixing argon and ethane drift chamber gas which is used for the E-605 experiment at Fermilab. This system is based on the idea of intermittent mixing of gases with fixed mixing flow rates. A dual-action pressure switch senses the pressure in a mixed gas reservoir tank and operates solenoid valves to control mixing action and regulate reservoir pressure. This system has the advantages that simple controls accurately regulate the mixing ratio and that the mix… more
Date: April 1, 1983
Creator: Cooper, William E.; Sugano, Katsuhito & Trentlage, Donald B.
Partner: UNT Libraries Government Documents Department
open access

Pressurized hopper

Description: A Secure Automated Fuel Fabrication Line is being developed to reduce personnel exposure and to improve safeguards. Fertile and fissile fuel powders are blended in the line for making fuel pellets. A pressurized hopper was developed for use not only as a blender, but also as a storage and feeding device. It works with or without injection tubes to produce a well-blended powder with reduced agglomerate population. Results of blending experiments using dry Kaolin clay and Tempra pigment are given… more
Date: April 1, 1980
Creator: Densley, P. J. & Goldmann, L. H., Jr.
Partner: UNT Libraries Government Documents Department
open access

Production-scale LLW and RMW solidification system operational testing at Argonne National Laboratory-East (ANL-E)

Description: Argonne National Laboratory-East (ANL-E) has begun production-scale testing of a low-level waste and radioactive mixed waste solidification system. This system will be used to treat low-level and mixed radioactive waste to meet land burial requirements. The system can use any of several types of solidification media, including a chemically bonded phosphate ceramic developed by ANL-E scientists. The final waste product will consist of a solidified mass in a standard 208-liter drum. The system us… more
Date: April 1, 1997
Creator: Wescott, J.; Wagh, A.; Singh, D.; Nelson, R. & No, H.
Partner: UNT Libraries Government Documents Department
open access

High Level Waste FLYGT Mixer, A Case History for Modal Analysis

Description: There are many tools available to help diagnose equipment vibration problems around the Savannah River Site. With the advancement of technology surrounding vibration analysis, modal analysis, an old, proven engineering modeling technique, can now be performed using the multi-channel machinery analyzer found in most predictive maintenance programs. The use of modal analysis can help eliminate problems with plant equipment that include failure to maintain tolerances, noisy equipment operation, ma… more
Date: April 10, 2001
Creator: Badger, R.L.
Partner: UNT Libraries Government Documents Department
open access

FY 97 Hanford telecommunication and information system userprofile - milestone IRM-097-003

Description: The purpose of this report is to provide the results of the first annual self-assessment to confirm readiness to replace the mixer pump (pump No.1) in Tank 241-SY-101, should the mixer pump fail or need to be replaced for some other reason.
Date: April 23, 1997
Creator: Witherspoon, T.T.
Partner: UNT Libraries Government Documents Department
open access

Project Execution Plan for Project W-211 Initial Tank Retrieval Systems (ITRS)

Description: This Project Execution Plan documents the methodology for managing Project W-211. Project W-211, Initial Tank Retrieval Systems (ITRS), is a fiscal year 1994 Major Systems Acquisition that will provide systems for retrieval of radioactive wastes from selected double-shell tanks (DST). The contents of these tanks are a combination of supernatant liquids and settled solids. To retrieve waste from the tanks, it is first necessary to mix the liquid and solids prior to transferring the slurry to alt… more
Date: April 19, 2000
Creator: Van Beek, J. E.
Partner: UNT Libraries Government Documents Department
open access

Double Shell Tank (DST) Monitor and Control Subsystem Specification

Description: This specification establishes the performance requirements and provides references to the requisite codes and standards to be applied during design of the Double-Shell Tank (DST) Monitor and Control Subsystem that supports the first phase of Waste Feed Delivery. This subsystem specification establishes the interface and performance requirements and provides references to the requisite codes and standards to be applied during the design of the Double-Shell Tank (DST) Monitor and Control Subsyst… more
Date: April 27, 2000
Creator: BAFUS, R.R.
Partner: UNT Libraries Government Documents Department
open access

CSER 00-001 Criticality Safety Evaluation Report for Cementation Operations at the PFP

Description: Glovebox HA-20MB is located in Room 235B of the 234-5Z Building at the Plutonium Finishing Plant. This enclosure contains mixers, mixer bowls, a crusher unit, an isolated inoperable conveyor unit, plutonium residue feed cans, cemented cans, and a feedwater container. Plutonium residue, not conducive to other forms of stabilization, is prepared for storage and ultimate disposal by cementation. The feed residue material cans can have plutonium contents of only a few grams or up to 200 grams. This… more
Date: April 18, 2000
Creator: Dobbin, K. D.
Partner: UNT Libraries Government Documents Department