High-Strength Materials for Pressurized-Water in-Pile Tubes

Description: The preliminary work done by Westinghouse on properties of materials suitable for the in-pile testing facility was reviewed. Information was collected on a selected list of promising materials in the following classificrtions: alloy steels, chromium steels, precipitation-hardening stainless steels, and superalloys. On the basis of the information obtained from Westinghouse, from the literature survey, from Battelle files, and from visits to producers, it is recommended that Phase II of the prog… more
Date: September 16, 1957
Creator: Simmons, W.F.; Boyd, W.K.; Sopher, R.P. & Lyon, F.H.
Partner: UNT Libraries Government Documents Department
open access

Diffusion bonding resistant valve development for sodium service

Description: Unanticipated functional failures occurred in valves undergoing containment integrity testing for liquid sodium service. The failures resulted from diffusion bonding of the Stellite 6B valve plug to the Type 316 stainless steel (SS) seat. As a result of these failures, a valve development program was undertaken. A modified valve incorporating a Tribaloy 800 plug showed significant improvement in resistance to diffusion bonding but still failed after long term exposure in a closed position. A se… more
Date: April 16, 1984
Creator: Crandall, D. L.; Low, J. O.; Chung, D. T. & Loop, R. B.
Partner: UNT Libraries Government Documents Department