Sparking and X-Rays in a Mercury Pumped Vacuum System (Excerpt From Quarterly Report for March, April, May, 1952 - Linac Group - UCRL-1903)
Description:
Sparking: The most obvious conclusion about 200 m.c. sparking is that it follows strictly surface gradient and does not depend upon total voltage. In order to arrive at this conclusion, a quantitative means for measuring the probability of sparking had to be constructed, since it was clearly evident that the d.c. notion of sparking was inadequate.
Date:
August 1952
Creator:
Kilpatrick, W.