UNT Libraries Government Documents Department - 863 Matching Results

Search Results

2-D Finite Element Cable and Box IEMP Analysis

Description: A 2-D finite element code has been developed for the solution of arbitrary geometry cable SGEMP and box IEMP problems. The quasi- static electric field equations with radiation- induced charge deposition and radiation-induced conductivity y are numerically solved on a triangular mesh. Multiple regions of different dielectric materials and multiple conductors are permitted.
Date: December 17, 1998
Creator: Scivner, G.J. & Turner, C.D.

A 2-D Self-Consistent DSMC Model for Chemically Reacting Low Pressure Plasma Reactors

Description: This paper will focus on the methodology of using a 2D plasma Direct Simulation Monte Carlo technique to simulate the species transport in an inductively coupled, low pressure, chemically reacting plasma system. The pressure in these systems is typically less than 20 mtorr with plasma densities of approximately 10{sup 17} {number_sign}/m{sup 3} and an ionization level of only 0.1%. This low ionization level tightly couples the neutral, ion, and electron chemistries and interactions in a system where the flow is subsonic. We present our strategy and compare simulation results to experimental data for Cl{sub 2} in a Gaseous Electronics Conference (GEC) reference cell modified with an inductive coil.
Date: June 17, 1999
Creator: Bartel, Timothy J.; Economou, Demetre & Johannes, Justine E.

45-day safety screen results for tank 241-U-204, push mode, cores 81 and 82

Description: This is the 45-Day report for the fiscal year 1995 tank 241-U-204 (U-204) push-mode characterization effort. Included are a summary of analytical results and copies of the differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) scans. Core samples 81 and 82 from tank U-204, obtained by the push-mode core sampling method, were received by the 222-S Laboratories. Each core consisted of only one segment. Both core samples and the field blank were extruded, subsampled, and analyzed in accordance with Reference 1. Drainable liquids and the field blank were analyzed at the segment level for energetics by DSC, percent water by TGA, and total organic carbon (TOC) by furnace oxidation. In addition, the presence or absence of any separable, presumably organic, layer in drainable liquid samples was noted and none was observed. The solids were analyzed directly at the half segment level for energetics by DSC, percent water by TGA, and TOC by persulfate oxidation. Total alpha activity was determined on fusion digestions of the sludge subsamples. No immediate notifications were necessary on samples from cores 81 or 82.
Date: May 17, 1995
Creator: Bell, K.E.

60 kilograms high explosive containment with multi-diagnostic capability

Description: In anticipation of increasingly stringent environmental regulations, Lawrence Livermore National Laboratory (LLNL) proposes to construct a 60 kilogram (kg) firing chamber to provide blast-effects containment for most of its open-air, high explosives, firing operations. Even though these operations are within current environmental limits, containment of the blast effects and hazardous debris will further drastically reduce emissions to the environment and minimize the generated hazardous waste.
Date: September 17, 1998
Creator: Simmons, L. F.

241-AZ-101 pump removal trough analysis

Description: As part of the current Hanford mission of environmental cleanup, various long length equipment must be removed from highly radioactive waste tanks. The removal of equipment will utilize portions of the Equipment Removal System for Project W320 (ERS-W320), specifically the 50 ton hydraulic trailer system. Because the ERS-W320 system was designed to accommodate much heavier equipment it is adequate to support the dead weight of the trough, carriage and related equipment for 241AZ101 pump removal project. However, the ERS-W320 components when combined with the trough and its` related components must also be analyzed for overturning due to wind loads. Two troughs were designed, one for the 20 in. diameter carriage and one for the 36 in. diameter carriage. A proposed 52 in. trough was not designed and, therefore is not included in this document. In order to fit in the ERS-W320 strongback the troughs were design with the same widths. Structurally, the only difference between the two troughs is that more material was removed from the stiffener plates on the 36 in trough. The reduction in stiffener plate material reduces the allowable load. Therefore, only the 36 in. trough was analyzed.
Date: October 17, 1995
Creator: Coverdell, B.L.

242-A evaporator safety analysis report

Description: This report provides a revised safety analysis for the upgraded 242-A Evaporator (the Evaporator). This safety analysis report (SAR) supports the operation of the Evaporator following life extension upgrades and other facility and operations upgrades (e.g., Project B-534) that were undertaken to enhance the capabilities of the Evaporator. The Evaporator has been classified as a moderate-hazard facility (Johnson 1990). The information contained in this SAR is based on information provided by 242-A Evaporator Operations, Westinghouse Hanford Company, site maintenance and operations contractor from June 1987 to October 1996, and the existing operating contractor, Waste Management Hanford (WMH) policies. Where appropriate, a discussion address the US Department of Energy (DOE) Orders applicable to a topic is provided. Operation of the facility will be compared to the operating contractor procedures using appropriate audits and appraisals. The following subsections provide introductory and background information, including a general description of the Evaporator facility and process, a description of the scope of this SAR revision,a nd a description of the basic changes made to the original SAR.
Date: May 17, 1999
Creator: CAMPBELL, T.A.

300 Area waste acid treatment system closure plan

Description: The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOERL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion includes closure plan documentation submitted for individual, treatment, storage, and/or disposal units undergoing closure, such as the 300 Area Waste Acid Treatment System. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Whenever appropriate, 300 Area Waste Acid Treatment System documentation makes cross-reference to the General Information Portion, rather than duplicating text. This 300 Area Waste Acid Treatment System Closure Plan (Revision 2) includes a Hanford Facility Dangerous Waste Permit Application, Part A, Form 3. Information provided in this closure plan is current as of April 1999.
Date: May 17, 1999
Creator: LUKE, S.N.

303-K Storage Facility report on FY98 closure activities

Description: This report summarizes and evaluates the decontamination activities, sampling activities, and sample analysis performed in support of the closure of the 303-K Storage Facility. The evaluation is based on the validated data included in the data validation package (98-EAP-346) for the 303-K Storage Facility. The results of this evaluation will be used for assessing contamination for the purpose of closing the 303-K Storage Facility as described in the 303-K Storage Facility Closure Plan, DOE/RL-90-04. The closure strategy for the 303-K Storage Facility is to decontaminate the interior of the north half of the 303-K Building to remove known or suspected dangerous waste contamination, to sample the interior concrete and exterior soils for the constituents of concern, and then to perform data analysis, with an evaluation to determine if the closure activities and data meet the closure criteria. The closure criteria for the 303-K Storage Facility is that the concentrations of constituents of concern are not present above the cleanup levels. Based on the evaluation of the decontamination activities, sampling activities, and sample data, determination has been made that the soils at the 303-K Storage Facility meet the cleanup performance standards (WMH 1997) and can be clean closed. The evaluation determined that the 303-K Building cannot be clean closed without additional closure activities. An additional evaluation will be needed to determine the specific activities required to clean close the 303-K Storage Facility. The radiological contamination at the 303-K Storage Facility is not addressed by the closure strategy.
Date: July 17, 1998
Creator: Adler, J. G.

A 600 MeV cyclotron for radioactive beam production

Description: The magnetic field design for a 600 MeV proton cyclotron is described. The cyclotron has a single stage, a normal conducting magnet coil and a 9.8 m outside yoke diameter. It has 8 sectors, with a transition to 4 sectors in the center region. The magnetic field design was done using 1958 Harwell rectangular ridge system measurements and was compared with recent 3-dimensional field calculations with the program TOSCA at NSCL. The center region 4--8 sector transition focussing was also checked with TOSCA.
Date: May 17, 1993
Creator: Clark, D. J.

12th Annual ALS Users' Association Meeting

Description: Science took the front seat as 219 Advanced Light Source (ALS) users and staff gathered on Monday and Tuesday, October 18 and 19 for the twelfth annual users' meeting. The bulk of the meeting was dedicated to reports on science at the ALS. Packed into two busy days were 31 invited oral presentations and 80 submitted poster presentations, as well as time to visit 24 vendor booths. The oral sessions were dedicated to environmental science, chemical dynamics, biosciences, magnetic materials, and atomic and molecular science. In addition, there was an ALS highlights session that emphasized new results and a session comprising highlights from the young scientists who will carry the ALS into the future.
Date: December 17, 1999
Creator: Robinson, Arthur L.

1972-1997, Twenty-five years of energy and environmental history : lessons learned.

Description: Given the events of the past 25 years concerning energy and environmental issues and our reaction to them, what lessons can we learn? First, the individual American consumer wants and expects energy to be a stable commodity with low prices and easy availability. As evidenced by the heated debate over increasing the federal gasoline tax by $.05 per gallon (which would still leave Americans paying only one-third of what Europeans pay for gasoline), increases in energy prices elicit very strong public and political opposition. As further evidence, it has been argued that the general public support of the Gulf War was due, in part, to a recognition of the need to maintain a stable source of cheap oil from the region. The American public wants to maintain the benefits of cheap and abundant energy and expects its political leaders to make it happen. A second lesson is that if constraints on the energy supply do occur (e.g., the OPEC-imposed oil embargo) ardor environmental impacts from energy use do appear to be significant (e.g., SO{sub 2} and CO{sub 2} emissions), the preference is for a technology fix rather than a behavioral change. This is evidenced by our reliance on moving low-sulfur coal more than 1,000 miles from Wyoming to burn in Illinois power plants rather than reducing the demand for electricity with energy-efficient measures in residential, commercial, and industrial activities. National research programs to produce an automobile that gets 80+ miles per gallon take higher priority over working to get people to use mass transit to reduce their driving mileage. Americans expect that advanced technology can be relied upon to come up with solutions to energy and environmental problems without having to change their lifestyles. The experience with natural gas, in which a regulatory change (deregulation) was combined with technology developments ...
Date: December 17, 1997
Creator: Drucker, H.

233U Assay A Neutron NDA System

Description: The assay of highly enriched {sup 233}U material presents some unique challenges. Techniques which apply to the assay of materials of Pu or enriched {sup 235}U do not convert easily over to the assay of {sup 233}U. A specialized neutron assay device is being fabricated to exploit the singles neutron signal, the weak correlated neutron signal, and an active correlated signal. These pieces of information when combined with {gamma} ray isotopics information should give a good overall determination of {sup 233}U material now stored in bldg. 3019 at the Oak Ridge National Laboratory.
Date: November 17, 1998
Creator: Hensley, D.C.; Lucero, A.J. & Pierce, L.

242T FACP replacement

Description: This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Fire Protection system functions as required by project criteria. This ATP will test the Pyrotronic CP-400 fire alarm control panel (FACP), and interfaces with the radio fire alarm reporting box, alarm/supervisory initiating devices, and alarm indicating appliances. This document is to certify the installation and testing of the fire alarm control panel and all attached devices to insure the Hanford Fire Dept. receives the proper signals. This fire alarm control panel is located in Bldg. 242T in the 200 W Area of Hanford.
Date: November 17, 1994
Creator: Ferry, M. F.

(The 25th international conference on high-energy physics at Singapore)

Description: The traveler attended the 25th International Conference on High-Energy Physics in Singapore, August 1--8, 1990. The conference was dominated by results from the new LEP accelerator at CERN. The precision of the data from LEP is impressive, and all results are consistent with the standard model. No new physics'' has emerged at LEP. The traveler presented a talk on CERN/SPS WA80 results and had several interesting, private discussions on both L* and WA80 topics.
Date: August 17, 1990
Creator: Plasil, F.

2707SX FACP replacement

Description: This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Fire Protection system functions as required by project criteria. This ATP will test the Pyrotronic CP-400 fire alarm control panel (FACP), and interfaces with the radio fire alarm reporting box, alarm/supervisory initiating devices, and alarm indicating appliances. This document is to certify the installation of the fire alarm control panel and all attached devices to insure the Hanford Fire Dept. receives the proper signals. This particular fire alarm control panel services Bldg. 2707SX in the 200W Area of Hanford.
Date: November 17, 1994
Creator: Ferry, M. F.

Abortion Procedures

Description: The Partial-Birth Abortion Ban Act of 1997, H.R. 1122 was vetoed by President Clinton on October 10, 1997. This legislation would have made it a federal crime, punishable by fine and/or incarceration, for a physician to perform a partial birth abortion unless it was necessary to save the life of a mother whose life is endangered by a physical disorder, illness, or injury. The partial-birth abortion legislation has stimulated a great deal of controversy. This report provides a brief overview of the abortion methods currently in use for which data have been published and some positions on the partial birth abortion legislation.
Date: November 17, 1997
Creator: Stith-Coleman, Irene

Acceptance for Beneficial Use Pumping Instrumentation and Control Skid L

Description: This is a final Acceptance for Beneficial Use (ABU) for Pumping and Instrumentation Control (PIC) skid ''L''. PIC skid ''L'' is ready for pumping tank U-105. All the testing and documentation has been completed as required on the ABU checklist. This ABU covers only the readiness of the PIC skid ''L''. Other U-farm preparations including dilution tank fabrication, portable exhauster readiness, leak detection, valve pit preparation, and the Operation Control Station readiness are not part of this ABU. PIC skid ''L'' is a new skid fabricated and tested at Site Fabrication Services. The skid controls the jet pump and monitors various instruments associated with the pumping operation. This monitoring includes leak detection along the waste transfer route and flammable gases in the pump pit.
Date: November 17, 1999
Creator: Koch, M. R.

Acceptance test report for the safety class shutdown system

Description: This document provides the Acceptance Test Report for the successful testing of the Safety Shutdown Circuit. The test was done in accordance with the requirements that were defined in WHC-SD-WM-SCH-003, Interim Stabilization Safety Class Trip Circuit CGI Dedication Criteria. The actual test procedure document was contained in WHC-SD-WM-ATP-185, Acceptance Test Procedure for the Safety Class Shutdown System.
Date: October 17, 1996
Creator: Zuroff, W.F.

ACP research and scientific coordination: Annual performance report

Description: This research grant addresses two primary objectives: 1. Conduct of specific research tasks under the DOE Atmospheric Chemistry Program (ACP), and 2. Provision of scientific coordination for the Atmospheric Chemistry Program. In summary, the project is progressing essentially as expected, with some minor exceptions. Higher than anticipated demands within Objective 2, associated primarily with the ACP Ozone Project and the recompetition of the National Laboratories protion of ACP, have resulted in a somewhat higher proportionate emphasis on the coordination activities associated with this objective. Also, the immediate need for pre-campaign modeling of the North Pacific has resulted in an acceleration of the Pacific modeling task relative to other tasks, particularly the Atlantic modeling task. Modeling activities in general have been delayed somewhat because of the noted Objective 2 demands and because of the extended time that was necessary to complete financial agreements for this grant.
Date: September 17, 1992
Creator: Hales, J. M.