UNT Libraries Government Documents Department - 786 Matching Results

Search Results

45-Day safety screen results for Tank 241-C-101, auger sample 95-AUG-019

Description: One auger sample from Tank 241-C-101 was received by the 222-S Laboratory and underwent safety screening analyses--differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha analysis--in accordance with the tank characterization plan. Analytical results for the TGA on the crust sample (the uppermost portion of the auger sample) (sample number S95T000823) were less than the safety screening notification limit of 17 weight percent water. Verbal and written notifications were made on May 3, 1995. No exotherms were observed in the DSC analyses and the total alpha results were well below the safety screening notification limit. This report includes the primary safety screening results obtained from the analyses and copies of all DSC and TGA raw data scans as requested per the TCP. Although not included in this report, a photograph of the extruded sample was taken and is available. This report also includes bulk density measurements required by Characterization Plant Engineering. Additional analyses (pH, total organic carbon, and total inorganic carbon) are being performed on the drainable liquid at the request of Characterization Process Control; these analyses will be reported at a later date in a final report for this auger sample. Tank C-101 is not part of any of the four Watch Lists.
Date: May 11, 1995
Creator: Sasaki, L.M.

97-ERD-022 final report: Supernova on Nova

Description: This is the final year of the 3-year LDRD-ERD involving Lasers, D&NT, Physics, and ILSA to develope astrophysics experiments on intense lasers such as the Nova and Gekko lasers. During this 3 year period, we have developed a highly successful experiment probing the hydrodynamics of the explosion phase of core-collapse supernovae, which occurs during the first ~3 hours after core collapse. This was in collaboration with the Univ. of Arizona and CEA/Saclay. We also developed a very successful experiment to probe the hydrodynamics of the later time, young remnant phase, meaning the first ~10-20 years after core collapse. This was in collaboration with the Univ. of Michigan and Univ. of Colorado. Finally, we developed during the final year an exquisite experiment to probe the dynamics of radiative, high Mach number astrophysical jets, in collaboration with the Univ. of Maryland and Osaka Univ. Each experiment has received very high visibility, with a multitude of publications, both in the technical journals (most importantly, the astrophysical journals) and in the popular press. The attached publication list shows 25 papers published or submitted to technical journals, 5 articles appearing in the popular press (including a cover story of Sky and Telescope), and 65 conference presentations, ~10 of which were invited talks. The most important papers to come out of this effort was a comprehensive theory paper for Ap. J. establishing the rigorous scaling between laboratory laser experiments and the astrophysical subjects of interest: supernovae, supernova remnants, and jets; and a review article for Science covering this emerging subfield of Astrophysics on Intense Lasers. Since there are so many publications that have resulted from this LDRD project, only these two most important papers are attached. The rest are properly referenced, and can be found online or in the library. In anticipation of the closing of ...
Date: March 11, 1999
Creator: Remington, B. A.

100-D Ponds groundwater quality assessment

Description: The 100-D Ponds facility is regulated under the Resource Conservation and Recovery Act of 1976. The pH of groundwater in a downgradient well is statistically different than local background, triggering an assessment of groundwater contamination under 40 CFR 265.93. Results of a similar assessment, conducted in 1993, show that the elevated pH is caused by the presence of alkaline ash sediments beneath the ponds, which are not part of the RCRA unit. The 100-D Ponds should remain in indicator evaluation monitoring.
Date: April 11, 1996
Creator: Hartman, M. J.

105-DR Large Sodium Fire Facility closure activities evaluation report

Description: This report evaluates the closure activities at the 105-DR Large Sodium Fire Facility. The evaluation compares these activities to the regulatory requirements and closure plan requirements. The report concludes that the areas identified in the closure plan can be clean closed. This report summarizes and evaluates the closure activities performed in support of partial closure of the 105-DR Large Sodium Fire Facility (LSFF). This evaluation will be used in assessing the condition of the 105-DR LSFF for the purpose of meeting the partial clean closure conditions described in the 105-DR Large Sodium Fire Facility Closure Plan (DOE-RL 1995). Based on the evaluation of the decontamination activities, sampling activities, and sample data, it is has been determined that the partial clean closure conditions for the 105-DR LSFF have been met.
Date: April 11, 1996
Creator: Adler, J. G.

241-SY-101 air lance removal lessons learned

Description: An emergency task was undertaken to remove four air lances and one thermocouple (TC) tree from tank 241-SY-101 (SY-101). This resulted from video observation that these pipes were being severely bent during periodic gas release events that regularly occurred every three to four months. At the time, the gas release events were considered to be the number one safety issue within the US Department of Energy (DOE) complex. This emergency removal task was undertaken on an extremely short schedule that required all activities possible to be completed in parallel. This approach and extremely short schedule, while successful, resulted in some undesirable consequences from less than desired time for design, reviews, equipment testing, operations training, and bad weather conditions. These consequences included leakage of liquid waste from the containers to the ground, higher than expected dose rates at the container surface, difficult field operations, and unexpected pipe configuration during removal. In addition, changes to environmental regulations and severe winter weather impacted the packaging and shipping activities required the prepare the removed pipes for storage at the Central Waste Complex (CWC). The purpose of this document is to identify lessons to be learned for future activities. In context of the emergency conditions that existed at the time and the urgency to remove these pipes, their removal was successfully completed under extremely difficult conditions and schedule. The success of the task should not be overshadowed by the desire to identify areas needing improvement and lessons to be learned. Many of the lessons identified in this document have already resulted in improved conduct of operations and engineering.
Date: October 11, 1994
Creator: Moore, T. L. & Titzler, P. A.

241-SY-101 data acquisition and control system (DACS) operator interface upgrade operational test report

Description: This procedure provides instructions for readiness of the first portion of the upgraded 241-SY-101 Data Acquisition and Control System (DACS) computer system to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank will be systematically evaluated by the performance of this procedure.
Date: May 11, 1999
Creator: Ermi, A. M.

300 Area treated effluent disposal facility sampling schedule

Description: This document is the interface between the 300 Area Liquid Effluent Process Engineering (LEPE) group and the Waste Sampling and Characterization Facility (WSCF), concerning process control samples. It contains a schedule for process control samples at the 300 Area TEDF which describes the parameters to be measured, the frequency of sampling and analysis, the sampling point, and the purpose for each parameter.
Date: October 11, 1994
Creator: Loll, C. M.

2D deterministic radiation transport with the discontinuous finite element method

Description: This report provides a complete description of the analytic and discretized equations for 2D deterministic radiation transport. This computational model has been checked against a wide variety of analytic test problems and found to give excellent results. We make extensive use of the discontinuous finite element method.
Date: November 11, 1993
Creator: Kershaw, D. & Harte, J.

Accelerated alpha radiation damage in a ceramic waste form, interim results

Description: Interim results are presented on the alpha-decay damage study of a {sup 238}Pu-loaded ceramic waste form (CWF). The waste form was developed to immobilize fission products and transuranic species accumulated from the electrometallurgical treatment of spent nuclear fuel. To evaluate the effects of {alpha}-decay damage on the waste form the {sup 238}Pu-loaded material was analyzed by (1) x-ray diffraction (XRD), (2) microstructure characterization by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) with energy and wavelength dispersive spectroscopy (EDS/WDS) and electron diffraction, (3) bulk density measurements and (4) waste form durability, performed by the product consistency test (PCT). While the predominate phase of plutonium in the CWF, PuO{sub 2}, shows the expected unit cell expansion due to {alpha}-decay damage, currently no significant change has occurred to the macro- or microstructure of the material. The major phase of the waste form is sodalite and contains very little Pu, although the exact amount is unknown. Interestingly, measurement of the sodalite phase unit cell is also showing very slight expansion; again, presumably from {alpha}-decay damage.
Date: November 11, 1999
Creator: Frank, S. M.; Johnson, S. G.; Moschetti, T. L.; O'Holleran, T. P.; Sinkler, W.; Esh, D. et al.

Acceleration of compact toruses and fusion applications

Description: The Compact Torus (Spheromak-type) is a near ideal plasma confinement configuration for acceleration. The fields are mostly generated by internal plasma currents, plasma confinement is toroidal, and the compact torus exhibits resiliency and stability in virtue of the ``rugged`` helicity invariant. Based on these considerations we are developing a coaxial rail-gun type Compact Torus Accelerator (CTA). In the CTA, the CT ring is formed between coaxial electrodes using a magnetized Marshall gun, it is quasistatically ``precompressed`` in a conical electrode section for inductive energy storage, it is accelerated in a straight-coaxial electrode section as in a conventional rail-gun, and it is focused to small size and high energy and power density in a final ``focus`` cone section. The dynamics of slow precompression and acceleration have been demonstrated experimentally in the RACE device with results in good agreement with 2-D MHD code calculations. CT plasma rings with 100 {micro}gms mass have been accelerated to 40 Kj kinetic energy at 20% efficiency with final velocity = 1 X 10{sup 8} cm/s (= 5 KeV/H{sup +}). Preliminary focus tests exhibi dynamics of radius compression, deceleration, and bouncing. Compression ratios of 2-3 have been achieved. A scaled-up 10-100 MJ CTA is predicted to achieve a focus radius of several cm to deliver = 30 MJ ring kinetic energy in 5-10 nsec. This is sufficient energy, power, and power density to enable the CTA to act as a high efficiency, low cost ICF driver. Alternatively, the focused CT can form the basis for an magnetically insulated, inertial confinement fusion (MICF) system. Preliminary calculations of these fusion systems will be discussed.
Date: October 11, 1990
Creator: Hartman, C.W.; Eddleman, J.L.; Hammer, J.H.; Logan, B.G.; McLean, H.S. & Molvik, A.W.

Acceptance test procedure for K basins dose reduction project clean and coat equipment

Description: This document is the Acceptance Test Procedure (ATP) for the clean and coat equipment designed by Oceaneering Hanford, Inc. under purchase order MDK-XVC-406988 for use in the 105 K East Basin. The ATP provides the guidelines and criteria to test the equipment`s ability to clean and coat the concrete perimeter, divider walls, and dummy elevator pit above the existing water level. This equipment was designed and built in support of the Spent Nuclear Fuel, Dose Reduction Project. The ATP will be performed at the 305 test facility in the 300 Area at Hanford. The test results will be documented in WHC-SD-SNF-ATR-020.
Date: March 11, 1996
Creator: Creed, R.F.

Active voltammetric microsensors with neural signal processing.

Description: Many industrial and environmental processes, including bioremediation, would benefit from the feedback and control information provided by a local multi-analyte chemical sensor. For most processes, such a sensor would need to be rugged enough to be placed in situ for long-term remote monitoring, and inexpensive enough to be fielded in useful numbers. The multi-analyte capability is difficult to obtain from common passive sensors, but can be provided by an active device that produces a spectrum-type response. Such new active gas microsensor technology has been developed at Argonne National Laboratory. The technology couples an electrocatalytic ceramic-metallic (cermet) microsensor with a voltammetric measurement technique and advanced neural signal processing. It has been demonstrated to be flexible, rugged, and very economical to produce and deploy. Both narrow interest detectors and wide spectrum instruments have been developed around this technology. Much of this technology's strength lies in the active measurement technique employed. The technique involves applying voltammetry to a miniature electrocatalytic cell to produce unique chemical ''signatures'' from the analytes. These signatures are processed with neural pattern recognition algorithms to identify and quantify the components in the analyte. The neural signal processing allows for innovative sampling and analysis strategies to be employed with the microsensor. In most situations, the whole response signature from the voltammogram can be used to identify, classify, and quantify an analyte, without dissecting it into component parts. This allows an instrument to be calibrated once for a specific gas or mixture of gases by simple exposure to a multi-component standard rather than by a series of individual gases. The sampled unknown analytes can vary in composition or in concentration, the calibration, sensing, and processing methods of these active voltammetric microsensors can detect, recognize, and quantify different signatures and support subsequent analyses. The instrument can be trained to recognize and report ...
Date: December 11, 1998
Creator: Vogt, M. C.

An adaptive optics package designed for astronomical use with a laser guide star tuned to an absorption line of atomic sodium

Description: We present the design and implementation of a very compact adaptive optic system that senses the return light from a sodium guide-star and controls a deformable mirror and a pointing mirror to compensate atmospheric perturbations in the wavefront. The deformable mirror has 19 electrostrictive actuators and triangular subapertures. The wavefront sensor is a Hartmann sensor with lenslets on triangular centers. The high-bandwidth steering mirror assembly incorporates an analog controller that samples the tilt with an avalanche photodiode quad cell. An {line_integral}/25 imaging leg focuses the light into a science camera that can either obtain long-exposure images or speckle data. In laboratory tests overall Strehl ratios were improved by a factor of 3 when a mylar sheet was used as an aberrator. The crossover frequency at unity gain is 30 Hz.
Date: April 11, 1994
Creator: Salmon, J. T.; Avicola, K. & Brase, J. M.

AN ADVANCED CONTROL SYSTEM FOR FINE COAL FLOTATION

Description: A model-based flotation control scheme is being implemented to achieve optimal performance in the handling and treatment of fine coal. The control scheme monitors flotation performance through on-line analysis of tailings ash content. Then, based on an on-line estimate of incremental ash, the pulp level is adjusted using a model-based control algorithm to compensate for feed variations and other process disturbances. Recent developments in sensor technology are being applied for on-line determination of slurry ash content. During the eleventh quarter of this project, Task 7 (Operation and Testing) was nearly completed through the efforts of J.A. Herbst and Associates, Virginia Tech, and Pittston Coal Company. As a result of this work, a model-based control system has now been installed which can predict incremental ash based on tailings ash content and general plant data, and adjust pulp level accordingly to maintain a target incremental ash. The system has gone through a shake-down period, training has been carried out for plant operators, and the bulk of the control logic testing has been completed with the results of these tests awaiting analysis under Task 8 (System Evaluation). The flotation model has been shown to predict incremental ash quite successfully, implying that this approach may provide the basis for a useful ''soft sensor'' for on-line incremental ash analysis.
Date: January 11, 1999
Creator: Luttrell, G. H. & Adel, G. T.