Search Results

open access

Design of a Monitoring System for a Plasma Cleaning Machine

Description: Plasma cleaning is the most effective dry process to remove surface contaminates from a SAW (Surface Acoustical Wave) device. Consistent gas pressures, flows, and good electrical connections between the chamber shelves are necessary for the process to function predictably. In addition, operation of the monitoring system must be transparent to the plasma cleaning unit. This thesis describes a simple solution to the complex problem of monitoring a plasma cleaning system. The monitoring system use… more
Date: May 1999
Creator: Fooks, Terry M. (Terry Max)

Development of a Coaxiality Indicator

Description: The geometric dimensioning and tolerancing concept of coaxiality is often required by design engineers for balance of rotating parts and precision mating parts. In current practice, it is difficult for manufacturers to measure coaxiality quickly and inexpensively. This study examines feasibility of a manually-operated, mechanical device combined with formulae to indicate coaxiality of a test specimen. The author designs, fabricates, and tests the system for measuring coaxiality of holes machine… more
Access: Restricted to UNT Community Members. Login required if off-campus.
Date: December 1999
Creator: Arendsee, Wayne C.
open access

A Computer-Based Process Control System for a Target Station in a LINAC Facility

Description: An event-driven, sequential, process control system was designed for International Isotopes, Inc., to automate and remotely control a target station at the company's linear accelerator facility. The designed system consisted of two major sections: a software program (virtual instrument), which was developed by LabVIEW, and a hardware interface (FieldPoint Modular Distributed I/O System by National Instrument), which had to be a pre-developed system that did not require customization. The design… more
Date: May 1999
Creator: Al-Shantaf, Abdulraouf O.