UNT Libraries - 2 Matching Results

Search Results

Cold-Formed Steel Bolted Connections Using Oversized and Slotted Holes without Washers

Description: In cold-formed steel (CFS) construction, bolted connections without washers for either oversized or slotted holes may significantly expedite the installation process and lower the cost. However, the North American Specification (AISI S100, 2007) for the Design of Cold-Formed Steel Structural Members requires washers to be installed in bolted connections with oversized or slotted holes. A research project (Phase 1) sponsored by American Iron and Steel Institute (AISI) was recently completed at the University of North Texas (UNT) that investigated the performance and strength of bolted CFS connections with oversized and slotted holes without using washers. The research presented in this thesis is the Phase 2 project in which the bolted CFS connections were studied in a broader respect in terms of the failure mechanism, the material thickness, and the hole configurations. Single shear and double shear connections without washers using oversized holes, oversized combined with standard or slotted holes were experimentally examined. Combined with Phase 1 results, the Phase 2 gives a comprehensive evaluation of the behavior and strength of bolted CFS connections with oversized and slotted holes without using washers. Revisions to the existing AISI North American Specification requirements for bolted connections are proposed to account for the reduction in the connection strength caused by the oversized and slotted hole configurations without washers. Specific LRFD and LSD resistance factors and ASD safety factors for different hole configurations in terms of the new proposed methods were presented.
Date: August 2010
Creator: Xu, Ke

Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing

Description: In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing.
Date: August 2010
Creator: Chen, Yujie