UNT Theses and Dissertations - 40 Matching Results

Search Results

Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers

Description: The HVAC&R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural corrosion behavior and its forms. Current results were gathered from five of ten samples that underwent initial testing. Finally, possible improvements towards the chamber system and the test method, including the salt solution, are discussed.
Access: This item is restricted to UNT Community Members. Login required if off-campus.
Date: May 2016
Creator: Vaughan, Haydn
Partner: UNT Libraries

Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing

Description: The cold-formed steel framed shear walls with steel sheets and wood-based sheathing are both code approved lateral force resisting system in light-framed construction. In the United States, the current design approach for cold-formed steel shear walls is capacity-based and developed from full-scale tests. The available design provisions provide nominal shear strength for only limited wall configurations. This research focused on the development of analytical models of cold-formed steel framed shear walls with steel sheet and wood-based sheathing to predict the nominal shear strength of the walls at their ultimate capacity level. Effective strip model was developed to predict the nominal shear strength of cold-formed steel framed steel sheet shear walls. The proposed design approach is based on a tension field action of the sheathing, shear capacity of sheathing-to-framing fastener connections, fastener spacing, wall aspect ratio, and material properties. A total of 142 full scale test data was used to verify the proposed design method and the supporting design equations. The proposed design approach shows consistent agreement with the test results and the AISI published nominal strength values. Simplified nominal strength model was developed to predict the nominal shear strength of cold-formed steel framed wood-based panel shear walls. The nominal shear strength is determined based on the shear capacity of individual sheathing-to-framing connections, wall height, and locations of sheathing-to-framing fasteners. The proposed design approach shows a good agreement with 179 full scale shear wall test data. This analytical method requires some efforts in testing of sheathing-to-framing connections to determine their ultimate shear capacity. However, if appropriate sheathing-to-framing connection capacities are provided, the proposed design method provides designers with an analytical tool to determine the nominal strength of the shear walls without conducting full-scale tests.
Date: May 2013
Creator: Yanagi, Noritsugu
Partner: UNT Libraries

Bearing Strength of Cold Formed Steel Bolted Connections in Trusses

Description: The existing design provision in North American Specification for Cold- Formed Steel Structural Member (AISI S100) for the bearing strength of bolted connections were developed from tests on bolted connected sheets which were restrained by bolt nut and head with or without washers. However, in the cold-formed assemblies, particularly in trusses, the single bolt goes through both sides of the connected sections, making the connected sheets on each side unrestrained. the warping of the unrestrained sheet may reduce the bearing strength of the bolted connection. This research investigates the behavior and strength of bearing failure in bolted connections in cold-formed steel trusses. Tensile tests were conducted on trusses connections with various material thicknesses. It was found that the AISI S100 works well for thick connections but provides unconservative predictions for thin materials. Based on the experimental results, a modified bearing strength method is proposed for calculating the bearing strength of bolted truss connections. the proposed method can be used for any cold-formed steel connections with unrestrained sheet.
Date: May 2012
Creator: Panyanouvong, Mark
Partner: UNT Libraries

Characterization of Iron Oxide Deposits Formed at Comanche Peak Steam Electric Station

Description: The presence of deposits leading to corrosion of the steam generator (SG) systems is a major contributor to operation and maintenance cost of pressurized water reactor (PWR) plants. Formation and transport of corrosion products formed due to the presence of impurities, metallic oxides and cations in the secondary side of the SG units result in formation of deposits. This research deals with the characterization of deposit samples collected from the two SG units (unit 1 and unit 2) at Comanche Peak Steam Electric Station (CPSES). X-ray diffraction (XRD), Fourier transform infrared spectrophotometry (FTIR), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) techniques have been used for studying the compositional and structural properties of iron oxides formed in the secondary side of unit 1 and unit 2. Magnetite (Fe3O4) was found to be predominant in samples from unit 1 and maghemite (g-Fe2O3) was found to be the dominant phase in case of unit 2. An attempt has been made to customize FTIR technique for analyzing different iron oxide phases present in the deposits of PWR-SG systems.
Access: This item is restricted to the UNT Community Members at a UNT Libraries Location.
Date: May 2003
Creator: Namduri, Haritha
Partner: UNT Libraries

Cold-Formed Steel Bolted Connections without Washers on Oversized and Slotted Holes

Description: The use of the cold-formed steel sheet bolted connections without washers is so significant; however, the North American Specifications for the Design of Cold Formed Steel Structural Members, NASPEC, doesn't provide provisions for such connections. The bearing failure of sheet and the shear failure of sheet were considered in this study. For the sheet shear strength, it was found that the NASPEC (2007) design provisions can be used for oversized holes in both single and double shear configurations and for the double shear connections on short slotted holes. For the sheet bearing strength, a new design method was proposed to be used for low and high ductile steel sheets. The method was compared with the NASPEC and the University of Waterloo approach. Washers were still required for single shear connections on short slotted holes. Besides, connections using ASTM A325 bolts yielded higher bearing strength than connections using ASTM A307 bolts.
Date: May 2009
Creator: Sheerah, Ibraheem
Partner: UNT Libraries

Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel

Description: Incombustibility is one important advantage of the sheet steel sheathed shear wall over wood panel sheathed shear wall. Compared to shear wall sheathed with plywood and OSB panel, shear wall sheathed with flat sheet steel behaved lower shear strength. Although shear wall sheathed with corrugated sheet steel exhibited high nominal strength and high stiffness, the shear wall usually behaved lower ductility resulting from brittle failure at the connection between the sheathing to frames. This research is aimed at developing modifications on the corrugated sheathing to improve the ductility of the shear wall as well as derive practical response modification factor by establishing correct relationship between ductility factor ? and response modification factor R. Totally 21 monotonic and cyclic full-scale shear wall tests were conducted during the winter break in 2012 by the author in NUCONSTEEL Materials Testing Laboratory in the University of North Texas. The research investigated nineteen 8 ft. × 4 ft. shear walls with 68 mil frames and 27 mil corrugation sheet steel in 11 configurations and two more shear walls sheathed with 6/17-in.OSB and 15/32-in. plywood respectively for comparison. The shear walls, which were in some special cutting arrangement patterns, performed better under lateral load conditions according to the behavior of ductility and shear strength and could be used as lateral system in construction.
Date: May 2013
Creator: Yu, Guowang
Partner: UNT Libraries

A Computer-Based Process Control System for a Target Station in a LINAC Facility

Description: An event-driven, sequential, process control system was designed for International Isotopes, Inc., to automate and remotely control a target station at the company's linear accelerator facility. The designed system consisted of two major sections: a software program (virtual instrument), which was developed by LabVIEW, and a hardware interface (FieldPoint Modular Distributed I/O System by National Instrument), which had to be a pre-developed system that did not require customization. The designed virtual instrument was tested on a simulation model that mimed the target station. The result was a valid design.
Date: May 1999
Creator: Al-Shantaf, Abdulraouf O.
Partner: UNT Libraries

Corrosion Protection of Low Carbon Steel By Cation Substituted Magnetite

Description: Surfaces of low carbon steel sheet were modified by exposure to highly caustic aqueous solutions containing either chromium or aluminum cations. Corrosion resistances of such surfaces were compared with that of steel surfaces exposed to plain caustic aqueous solution. In all cases a highly uniform, black coating having a spinel structure similar to magnetite (Fe3O4) was obtained. The coated steel surfaces were characterized using X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectrophotometry (FTIR). Polarization resistances (Rp) of modified steel surfaces were measured and compared with that of bare steel surfaces. Results indicate that chromium (Fe2+ Fe3+x Cr3+1-x) or aluminum (Fe2+ Fe3+x Al3+1-x) substituted spinel phases formed on steel surfaces showed higher Rp values compared to only magnetite (Fe2+ 2Fe3+O4) phase formed in the absence of either chromium or aluminum cations. Average Rp values for steel surfaces with chromium containing spinel phase were much higher (21.8 k?) as compared to 1.7 k? for bare steel surfaces. Steel surfaces with aluminum containing spinel phase and steels with plain magnetite coated samples showed average Rp values of 3.3 k? and 2.5 k? respectively. XPS and EDS analysis confirmed presence of cations of chromium and aluminum in Fe3O4 in cation substituted samples. FTIR results showed all coating phases were of spinel form with major absorption bands centered at either 570 cm-1 or 600 cm-1 assigned to Fe3O4 and ?-Fe2O3 respectively.
Date: May 2013
Creator: Phadnis, Ameya
Partner: UNT Libraries

A Data Acquisition System Experiment for Gas Temperature and Pressure Measurements on a Liquid-Nitrogen-Powered Vehicle

Description: A data acquisition system was set up to measure gas temperatures and pressures at various points on a liquid-nitrogen-powered vehicle. The experiment was attempted to develop a data acquisition method for applications on engines that use liquid air as the fuel. Two thermocouples and a pressure transducer were connected using data acquisition instruments interfaced to a laptop computer to acquire data.
Date: May 1998
Creator: Lui, Samson Sze-Sang
Partner: UNT Libraries

Design, Modeling, and Experiment of a Piezoelectric Pressure Sensor based on a Thickness-Shear Mode Crystal Resonator

Description: This thesis presents the design, modeling, and experiment of a novel pressure sensor using a dual-mode AT-cut quartz crystal resonator with beat frequency analysis based temperature compensation technique. The proposed sensor can measure pressure and temperature simultaneously by a single AT-cut quartz resonator. Apart from AT-cut quartz crystal, a newly developed Langasite (LGS) crystal resonator is also considered in the proposed pressure sensor design, since LGS can operate in a higher temperature environment than AT-cut quartz crystal. The pressure sensor is designed using CAD (computer aided design) software and CAE software - COMSOL Multiphysics. Finite element analysis (FEA) of the pressure sensor is performed to analyze the stress- strain of the sensor's mechanical structure. A 3D printing prototype of the sensor is fabricated and the proposed sensing principle is verified using a force-frequency analysis apparatus. Next to the 3D printing model verification, the pressure sensor with stainless steel housing has been fabricated with inbuilt crystal oscillator circuit. The oscillator circuit is used to excite the piezo crystal resonator at its fundamental vibrational mode and give the frequency as an output signal. Based on the FEA and experimental results, it has been concluded that the maximum pressure that the sensor can measure is 45 (psi). The pressure test results performed on the stainless steel product shows a highly linear relationship between the input (pressure) and the output (frequency).
Date: May 2017
Creator: Pham, Thanh Tuong
Partner: UNT Libraries

Design of a Monitoring System for a Plasma Cleaning Machine

Description: Plasma cleaning is the most effective dry process to remove surface contaminates from a SAW (Surface Acoustical Wave) device. Consistent gas pressures, flows, and good electrical connections between the chamber shelves are necessary for the process to function predictably. In addition, operation of the monitoring system must be transparent to the plasma cleaning unit. This thesis describes a simple solution to the complex problem of monitoring a plasma cleaning system. The monitoring system uses the LabVIEW® G programming language and hardware, both products of National Instruments, Inc.®, to monitor critical parameters necessary to achieve a consistent process when cleaning these devices.
Date: May 1999
Creator: Fooks, Terry M. (Terry Max)
Partner: UNT Libraries

Design of Power Amplifier Test Signals with a User-Defined Multisine

Description: Cellular radio communication involves wireless transmission and reception of signals at radio frequencies (RF). Base stations house equipment critical to the transmission and reception of signals. Power amplifier (PA) is a crucial element in base station assembly. PAs are expensive, take up space and dissipate heat. Of all the elements in the base station, it is difficult to design and operate a power amplifier. New designs of power amplifiers are constantly tested. One of the most important components required to perform this test successfully is a circuit simulator model of an entire communication system that generates a standard test signal. Standard test signals 524,288 data points in length require 1080 hours to complete one test of a PA model. In order to reduce the time taken to complete one test, a 'simulated test signal,' was generated. The objective of this study is to develop an algorithm to generate this 'simulated' test signal such that its characteristics match that of the 'standard' test signal.
Access: This item is restricted to UNT Community Members. Login required if off-campus.
Date: May 2004
Creator: Nagarajan, Preeti
Partner: UNT Libraries

Determination of the Shelf Life of Aluminum Electrolytic Capacitors.

Description: The aluminum electrolytic capacitor is used extensively in the electric utility industry. A factor limiting the storage of spare capacitors is the integrity of the aluminum oxide dielectric, which over time breaks down contributing to a shelf life currently estimated at one nuclear power electric generating station to be approximately five years. This project examined the electrical characteristics of naturally aged capacitors of several different styles to determine if design parameters were still within limits. Additionally, the effectiveness of a technique known as “Reforming” was examined to determine its impact on those characteristics.
Date: May 2002
Creator: Wynne, Edward McFaddin
Partner: UNT Libraries

Direct Strength Method for Web Crippling of Cold-formed Steel C-sections

Description: Web crippling is a form of localized buckling that occurs at points of transverse concentrated loading or supports of thin-walled structural members. The theoretical computation of web crippling strength is quite complex as it involves a large number of factors such as initial imperfections, local yielding at load application and instability of web. The existing design provision in North American specification for cold-formed steel C-sections (AISI S100, 2007) to calculate the web-crippling strength is based on the experimental investigation. The objective of this research is to extend the direct strength method to the web crippling strength of cold-formed steel C-sections. ABAQUS is used as a main tool to apply finite element analysis and is used to do the elastic buckling analysis. The work was carried out on C-sections under interior two flange (ITF) loading, end two flange (ETF) loading cases. Total of 128 (58 ITF, 70 ETF) sections were analyzed. Sections with various heights (3.5 in.to 6 in.) and various lengths (21 in. to 36 in.) were considered. Data is collected from the tests conducted in laboratory and the data from the previous researches is used, to extend the direct strength method to cold formed steel sections. Proposing a new design for both the loading cases and calculation of the resistance factors under (AISI S100, 2007) standards is done.
Date: May 2013
Creator: Seelam, Praveen Kumar Reddy
Partner: UNT Libraries

Effects of Processing Techniques on Mechanical Properties of Selected Polymers

Description: The mechanical properties of a polymer represent the critical characteristics to be considered when determining the applications for it. The same polymer processed with different methods can exhibit different mechanical properties. The purpose of this study is to investigate the difference in mechanical properties of the selected polymers caused by different processing techniques and conditions. Three polymers were studied, including low density polyethylene (LDPE), polypropylene (PP), and NEXPRENE® 1287A. Samples were processed with injection molding and compression molding under different processing condition. Tensile and DMA tests were performed on these samples. The acquired data of strain at break from the tensile tests and storage modulus from the DMA were utilized to calculate brittleness. Calculated brittleness values were used to perform analysis of variance (ANOVA) to investigate the statistical significance of the processing technique and condition. It was found that different processing techniques affect the brittleness significantly. The processing technique is the major factor affecting brittleness of PP and NEXPRENE, and the processing temperature is the major factor affecting brittleness of LDPE.
Date: May 2013
Creator: Dong, Yao
Partner: UNT Libraries

Effects of Rebar Temperature and Water to Cement Ratio on Rebar-Concrete Bond Strength of Concrete Containing Fly Ash

Description: This research presents the results on an experimental investigation to identify the effects of rebar temperature, fly ash and water to cement ratio on concrete porosity in continuously reinforced concrete pavements (CRCP). Samples were cast and analyzed using pullout tests. Water to cement ratio (w/c) and rebar temperature had a significant influence on the rebar-concrete bond strength. The 28-day shear strength measurements showed an increase in rebar-concrete bond strength as the water to cement ratio (w/c) was reduced from 0.50 to 0.40 for both fly ash containing and non fly ash control samples. There was a reduction in the peak pullout load as the rebar surface temperature increased from 77o F to 150o F for the cast samples. A heated rebar experiment was performed simulating a rebar exposed to hot summer days and the rebar cooling curves were plotted for the rebar temperatures of 180o F - 120o F. Fourier transform infrared spectroscopy was performed to show the moisture content of cement samples at the rebar-concrete interface. Mercury intrusion porosimetry test results on one batch of samples were used for pore size distribution analysis. An in-depth analysis of the morphological characteristics of the rebar-concrete interface and the observation of pores using the scanning electron microscope (SEM) was done.
Date: May 2010
Creator: Pati, Ardeep Ranjan
Partner: UNT Libraries

Effects of Thickness and Indenter Tip Geometry in Nanoindentation of Nickel Films

Description: Nanoindentation has become a widely used technique to measure the mechanical properties of materials. Due to its capability to deform materials in micro- and nano-scale, nanoindentation has found more applications in characterizing the deformation behavior and determining the mechanical properties of thin films and coatings. This research deals with the characterization of samples received from Center for Advanced Microstructures and Devices (CAMD) and Integran Technologies Inc., Toronto, Canada and the objective of this investigation was to utilize the experimental data obtained from nanoindentation to determine the deformation behavior, mechanical properties of thin films on substrates and bulk materials, and the effect of geometrically different indenters (Berkovich, cubecorner, and conical). X-ray diffraction (XRD), transmission electron microscope (TEM), scanning electron microscopy (SEM), and atomic force microscopy (AFM) analysis were performed on these materials to determine the crystal orientation, grain size of the material, and also to measure any substrate effects like pile-up or sin-in respectively. The results indicate that indentation size effect (ISE) strongly depends on shape of the indenter and less sensitive to penetration depth where as the hardness measurements depends on shape of indenter and depth of penetration. There is a negligible strain rate dependency of hardness at deeper depths and a significant increase in the hardness due to the decrease in grain size and results also indicate that there is no significant substrate effect on thin films for 10% and 20% of film thicknesses. Nanocrystalline material could not validate a dislocation based mechanisms deformation for indentation made by cubecorner and conical indenters in depths less than 1mm.
Access: This item is restricted to UNT Community Members. Login required if off-campus.
Date: May 2004
Creator: Parakala, Padma
Partner: UNT Libraries

Flow Accelerated Corrosion Experience at Comanche Peak Steam Electric Station

Description: Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and "chimney" like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes.
Date: May 2008
Creator: Nakka, Ravi Kumar
Partner: UNT Libraries

FPGA Prototyping of a Watermarking Algorithm for MPEG-4

Description: In the immediate future, multimedia product distribution through the Internet will become main stream. However, it can also have the side effect of unauthorized duplication and distribution of multimedia products. That effect could be a critical challenge to the legal ownership of copyright and intellectual property. Many schemes have been proposed to address these issues; one is digital watermarking which is appropriate for image and video copyright protection. Videos distributed via the Internet must be processed by compression for low bit rate, due to bandwidth limitations. The most widely adapted video compression standard is MPEG-4. Discrete cosine transform (DCT) domain watermarking is a secure algorithm which could survive video compression procedures and, most importantly, attacks attempting to remove the watermark, with a visibly degraded video quality result after the watermark attacks. For a commercial broadcasting video system, real-time response is always required. For this reason, an FPGA hardware implementation is studied in this work. This thesis deals with video compression, watermarking algorithms and their hardware implementation with FPGAs. A prototyping VLSI architecture will implement video compression and watermarking algorithms with the FPGA. The prototype is evaluated with video and watermarking quality metrics. Finally, it is seen that the video qualities of the watermarking at the uncompressed vs. the compressed domain are only 1dB of PSNR lower. However, the cost of compressed domain watermarking is the complexity of drift compensation for canceling the drifting effect.
Date: May 2007
Creator: Cai, Wei
Partner: UNT Libraries

Increasing the Dynamic Range of Audio THD Measurements Using a Novel Noise and Distortion Canceling Methodology

Description: The objective of this study was to determine how a new experimental methodology for measuring Total-Harmonic-Distortion (THD) of operational amplifiers functioned when compared with two standard methodologies, and whether the new methodology offers any improvement in noise floor and dynamic range along with distortion canceling of the sine-wave source used in the testing. The new methodology (THD) is being tested against two standard methodologies: Spectral Analysis using a tuned receiver type Spectrum Analyzer with Notch Filter pre-processing, and a digitized Fast Fourier Transform (FFT) using Notch Filter pre-processing. The THD results appear to agree across all methodologies, and across all items of the sample within all methodologies, to within a percent or less. The distortion and noise canceling feature of the new methodology appeared to function as expected and in accordance with theory. The sample tested in the study consisted of thirty-five NE5534 operational amplifiers produced by Texas Instruments, Inc. and purchased from a local store. The NE5534 is a low-noise, low-distortion, operational amplifier that is widely used in industry and is representative of today's best audio amplifiers.
Access: This item is restricted to UNT Community Members. Login required if off-campus.
Date: May 2003
Creator: Dunipace, Richard Alan
Partner: UNT Libraries

Innovative Cold-Formed Steel Shear Walls with Corrugated Steel Sheathing

Description: This thesis presents two major sections with the objective of introducing a new cold-formed steel (CFS) shear wall system with corrugated steel sheathings. The work shown herein includes the development of an optimal shear wall system as well as an optimal slit configuration for the CFS corrugated sheathings which result in a CFS shear wall with high ductility, high strength, high stiffness and overall high performance. The conclusion is based on the results of 36 full-scale shear wall tests performed in the structural laboratory of the University of North Texas. A variety of shear walls were the subject of this research to make further discussions and conclusions based on different sheathing materials, slit configurations, wall configurations, sheathing connection methods, wall dimensions, shear wall member thicknesses, and etc. The walls were subject to cyclic (CUREE protocol) lateral loading to study their deformations and structural performances. The optimal sit configuration for CFS shear walls with corrugated steel sheathings was found to be 12×2 in. vertical slits in 6 rows. The failure mode observed in this shear wall system was the connection failure between the sheathing and the framing members. Also, most of the shear walls tested displayed local buckling of the chord framing members located above the hold-down locations. The second section includes details of developing a Finite Element Model (FEM) in ABAQUS software to analyze the lateral response of the new shear wall systems. Different modeling techniques were used to define each element of the CFS shear wall and are reported herein. Material properties from coupon test results are applied. Connection tests are performed to define pinching paths to model fasteners with hysteretic user-defined elements. Element interactions, boundary conditions and loading applications are consistent with full scale tests. CFS members and corrugated sheathings are modeled with shell elements, sheathing-to-frame fasteners are ...
Access: This item is restricted to UNT Community Members. Login required if off-campus.
Date: May 2016
Creator: Mahdavian, Mahsa
Partner: UNT Libraries

Investigation of Spray Cooling Schemes for Dynamic Thermal Management

Description: This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems. Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency. Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. HFE-7100 dielectric liquid is selected as the working fluid. Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices. The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 μm thick copper-based coating prepared by dual stage electroplating technique. Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and ~10°C subcooling. Steady flow spray cooling tests are conducted at flow rates of 2 - 5 ml/cm².s, by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves in the form of surface superheat vs. heat flux. Variable flow and intermittent flow spray cooling tests are done at selected flowrate and subcooling conditions to investigate the effects of dynamic flow conditions on maintaining the target surface temperatures defined based on reference steady flow spray cooling performance.
Date: May 2017
Creator: Yata, Vishnu Vardhan Reddy
Partner: UNT Libraries

Laser Cutting Machine: Justification of initial costs

Description: The Industrial Laser is firmly established in metalcutting as the tool of choice for many applications. The elevator division of Montgomery KONE Inc., in an effort to move towards quality, ontime, complete deliveries and 100% customer satisfaction, decided to invest in new equipment to improve manufacturing processes. A huge investment is proposed for a laser-cutting machine. It is the responsibility of Manufacturing Engineering to direct the management by justifying its benefits, which includes payback time and financial gains. Factors such as common line cutting, automated material handling system and cutting time were involved in justification of the initial cost of a laser-cutting machine. Comparative statistics on appropriate factors accurately determine and justify the initial cost of a laser-cutting machine.
Date: May 2001
Creator: Nagaraja, Dwarakish
Partner: UNT Libraries