We present a controlled-aperture wave-equation migration method that no1 only can reduce migration artiracts due to limited recording aperlurcs and determine image weights to balance the efl'ects of limited-aperture illumination, but also can improve thc migration accuracy by reducing the slowness perturbations within thc controlled migration regions. The method consists of two steps: migration aperture scan and controlled-aperture migration. Migration apertures for a sparse distribution of shots arc determined using wave-equation migration, and those for the other shots are obtained by interpolation. During the final controlled-aperture niigration step, we can select a reference slowness in c;ontrollecl regions of the slowness ... continued below

Physical Description

4 p.

Creation Information

Huang, L. (Lian-Jie); Fehler, Michael C.; Sun, H. (Hongchuan) & Li, Z. (Zhiming) January 1, 2003.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

We present a controlled-aperture wave-equation migration method that no1 only can reduce migration artiracts due to limited recording aperlurcs and determine image weights to balance the efl'ects of limited-aperture illumination, but also can improve thc migration accuracy by reducing the slowness perturbations within thc controlled migration regions. The method consists of two steps: migration aperture scan and controlled-aperture migration. Migration apertures for a sparse distribution of shots arc determined using wave-equation migration, and those for the other shots are obtained by interpolation. During the final controlled-aperture niigration step, we can select a reference slowness in c;ontrollecl regions of the slowness model to reduce slowncss perturbations, and consequently increase the accuracy of wave-equation migration inel hods that makc use of reference slownesses. In addition, the computation in the space domain during wavefield downward continuation is needed to be conducted only within the controlled apertures and therefore, the computational cost of controlled-aperture migration step (without including migration aperture scan) is less than the corresponding uncontrolled-aperture migration. Finally, we can use the efficient split-step Fourier approach for migration-aperture scan, then use other, more accurate though more expensive, wave-equation migration methods to perform thc final controlled-apertio.ee migration to produce the most accurate image.

Physical Description

4 p.

Source

  • Submitted to: SEG 2003 International Exposition and 73rd Annual Meeting

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LA-UR-03-2539
  • Grant Number: none
  • Office of Scientific & Technical Information Report Number: 976605
  • Archival Resource Key: ark:/67531/metadc935298

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • January 1, 2003

Added to The UNT Digital Library

  • Nov. 13, 2016, 7:26 p.m.

Description Last Updated

  • Dec. 12, 2016, 5:45 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Huang, L. (Lian-Jie); Fehler, Michael C.; Sun, H. (Hongchuan) & Li, Z. (Zhiming). Controlled-aperture wave-equation migration, article, January 1, 2003; United States. (digital.library.unt.edu/ark:/67531/metadc935298/: accessed December 18, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.