Criticality benchmark calculations using PARTISN: Comparisons using MENDF5 and MENDF6 nuclear data libraries.

PDF Version Also Available for Download.

Description

A project was undertaken to assess the MENDF5 and MENDF6 nuclear data libraries through the analysis of 86 critical assembly benchmarks using the LANL discrete ordinates transport code PARTISN. As an initial analysis of the effects of some limitations in the MENDF libraries, this current work assesses differences in k,,a calculations between the PARTISN cases (with MENDF5 and MENDF6 nuclear data libraries) and MCNP cases, and compares these results to the experimental data.

Physical Description

[4] p.

Creation Information

Ellis, Ronald J.; Yugo, James J.; Frankle, S. C. (Stephanie C.) & Little, R. C. (Robert C.) January 1, 2003.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

A project was undertaken to assess the MENDF5 and MENDF6 nuclear data libraries through the analysis of 86 critical assembly benchmarks using the LANL discrete ordinates transport code PARTISN. As an initial analysis of the effects of some limitations in the MENDF libraries, this current work assesses differences in k,,a calculations between the PARTISN cases (with MENDF5 and MENDF6 nuclear data libraries) and MCNP cases, and compares these results to the experimental data.

Physical Description

[4] p.

Source

  • Submitted to: American Nuclear Society Annual Meeting, June 1 - 5, 2003, San Diego, CA

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LA-UR-03-1052
  • Grant Number: none
  • Office of Scientific & Technical Information Report Number: 976557
  • Archival Resource Key: ark:/67531/metadc932031

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • January 1, 2003

Added to The UNT Digital Library

  • Nov. 13, 2016, 7:26 p.m.

Description Last Updated

  • Dec. 12, 2016, 5:46 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Ellis, Ronald J.; Yugo, James J.; Frankle, S. C. (Stephanie C.) & Little, R. C. (Robert C.). Criticality benchmark calculations using PARTISN: Comparisons using MENDF5 and MENDF6 nuclear data libraries., article, January 1, 2003; United States. (digital.library.unt.edu/ark:/67531/metadc932031/: accessed September 23, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.