Aerial images for isolated defects and the interactions of defects with features are compared between the Actinic Inspection Tool (AIT) at Lawrence Berkeley National Laboratory (LBNL) and the fast EUV simulation program RADICAL. Comparisons between AIT images from August 2007 and RADICAL simulations are used to extract aberrations. At this time astigmatism was the dominant aberration with a value of 0.55 waves RMS. Significant improvements in the imaging performance of the AIT were made between August 2007 and December 2008. A good match will be shown between the most recent AIT images and RADICAL simulations without aberrations. These comparisons will ...
continued below
Publisher Info:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (United States)
Place of Publication:
Berkeley, California
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
Aerial images for isolated defects and the interactions of defects with features are compared between the Actinic Inspection Tool (AIT) at Lawrence Berkeley National Laboratory (LBNL) and the fast EUV simulation program RADICAL. Comparisons between AIT images from August 2007 and RADICAL simulations are used to extract aberrations. At this time astigmatism was the dominant aberration with a value of 0.55 waves RMS. Significant improvements in the imaging performance of the AIT were made between August 2007 and December 2008. A good match will be shown between the most recent AIT images and RADICAL simulations without aberrations. These comparisons will demonstrate that a large defect, in this case 7nm tall on the surface, is still printable even if it is centered under the absorber line. These comparisons also suggest that the minimum defect size is between 1.5nm and 0.8nm surface height because a 1.5nm defect was printable but a 0.8nm was not. Finally, the image of a buried defect near an absorber line through focus will demonstrate an inversion in the effect of the defect from a protrusion of the dark line into the space to a protrusion of the space into the line.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Clifford, C. H.; Wiraatmadja, S.; Chan, T. T.; Neureuther, A. R.; Goldberg, K. A.; Mochi, I. et al.Comparison of fast 3D simulation and actinic inspection for EUV masks with buries defects,