Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit Metadata

Metadata describes a digital item, providing (if known) such information as creator, publisher, contents, size, relationship to other resources, and more. Metadata may also contain "preservation" components that help us to maintain the integrity of digital files over time.

Title

  • Main Title Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit

Creator

  • Author: Huang, Zhenyu
    Creator Type: Personal
  • Author: faris, Anthony J.
    Creator Type: Personal
  • Author: Martin, Kenneth E.
    Creator Type: Personal
  • Author: Hauer, John F.
    Creator Type: Personal
  • Author: Bonebrake, Christopher A.
    Creator Type: Personal
  • Author: Shaw, James M.
    Creator Type: Personal

Contributor

  • Sponsor: United States. Department of Energy.
    Contributor Type: Organization

Publisher

  • Name: Pacific Northwest National Laboratory (U.S.)
    Place of Publication: Richland, Washington
    Additional Info: Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

Date

  • Creation: 2007-12-01

Language

  • English

Description

  • Content Description: PNNL and BPA have been in close collaboration on laboratory performance evaluation of phasor measurement units for over ten years. A series of evaluation tests are designed to confirm accuracy and determine measurement performance under a variety of conditions that may be encountered in actual use. Ultimately the testing conducted should provide parameters that can be used to adjust all measurements to a standardized basis. These tests are performed with a standard relay test set using recorded files of precisely generated test signals. The test set provides test signals at a level and in a format suitable for input to a PMU that accurately reproduces the signals in both signal amplitude and timing. Test set outputs are checked to confirm the accuracy of the output signal. The recorded signals include both current and voltage waveforms and a digital timing track used to relate the PMU measured value with the test signal. Test signals include steady-state waveforms to test amplitude, phase, and frequency accuracy, modulated signals to determine measurement and rejection bands, and step tests to determine timing and response accuracy. Additional tests are included as necessary to fully describe the PMU operation. Testing is done with a BPA phasor data concentrator (PDC) which provides communication support and monitors data input for dropouts and data errors.
  • Physical Description: PDFN

Subject

  • Keyword: Pmu
  • Keyword: Transducers
  • Keyword: Performance Testing Pmu
  • Keyword: Time Synchronization
  • STI Subject Categories: 24 Power Transmission And Distribution
  • Keyword: Power Transmission Lines
  • Keyword: Sel-421
  • Keyword: Measuring Instruments
  • Keyword: Load Management
  • Keyword: Phasor Measurement Unit
  • Keyword: Accuracy

Collection

  • Name: Office of Scientific & Technical Information Technical Reports
    Code: OSTI

Institution

  • Name: UNT Libraries Government Documents Department
    Code: UNTGD

Resource Type

  • Report

Format

  • Text

Identifier

  • Report No.: PNNL-16852
  • Grant Number: AC05-76RL01830
  • DOI: 10.2172/940755
  • Office of Scientific & Technical Information Report Number: 940755
  • Archival Resource Key: ark:/67531/metadc902409