Active polarimeter optical system laser hazard analysis. Page: 3 of 20
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
SAND2005-3583
Unlimited Release
Printed July 2005
Active Polarimeter Optical System
Laser Hazard Analysis
Arnold L. Augustoni
Lasers, Optics & Remote Sensing Department
Sandia National Laboratories
P.O. Box 5800
Albuquerque, NM 87185-1423
Abstract
A laser hazard analysis was performed for the SNL Active Polarimeter Optical
System based on the ANSI Standard Z136.1-2000, American National Standard
for Safe Use of Lasers and the ANSI Standard Z136.6-2000, American National
Standard for Safe Use of Lasers Outdoors.3
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Augustoni, Arnold L. Active polarimeter optical system laser hazard analysis., report, July 1, 2005; United States. (https://digital.library.unt.edu/ark:/67531/metadc898877/m1/3/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.