Adjustable Shock Test Sled for Haversine Pulses at 250 fps

PDF Version Also Available for Download.

Description

New test requirements were developed by Sandia National Laboratory to simulate a regime of shock testing not previously performed at the Kansas City Plant operated by Honeywell Federal Manufacturing & Technologies. These environments were unique in that they involved amplitude of shock >1000g with relatively long pulse durations (greater 5 ms but less than 10 ms) and involved velocity changes up to 235 ft/sec. Ten months were available to develop, design, manufacture and prove-in this new capability. We designed a new shock sled to deliver this new family of shock environments in a laboratory test. The performance range of the ... continued below

Creation Information

Hartwig, Troy; Hower, Brent & Seaholm, Aaron May 5, 2008.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

New test requirements were developed by Sandia National Laboratory to simulate a regime of shock testing not previously performed at the Kansas City Plant operated by Honeywell Federal Manufacturing & Technologies. These environments were unique in that they involved amplitude of shock >1000g with relatively long pulse durations (greater 5 ms but less than 10 ms) and involved velocity changes up to 235 ft/sec. Ten months were available to develop, design, manufacture and prove-in this new capability. We designed a new shock sled to deliver this new family of shock environments in a laboratory test. The performance range of the new sled includes five specific shocks (1000 g – 8 ms, 1300 - 6 ms, 1500 g – 5.4 ms, 1950 g – 6 ms, 2250 g – 5.4 ms; all haversine shaped), and it also incorporates adjustability to accommodate new shocks within this range. These shock environments result in velocity changes ranging from 160 fps to 250 fps. The test sled accommodates test articles weighing up to 20 lbs and measuring up to 10” along any axis.

Source

  • 78th Shock and Vibration Symposium Proceedings, Fall 2008

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: KCP-613-8445
  • Grant Number: AC04-01AL66850
  • Office of Scientific & Technical Information Report Number: 932961
  • Archival Resource Key: ark:/67531/metadc897943

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • May 5, 2008

Added to The UNT Digital Library

  • Sept. 27, 2016, 1:39 a.m.

Description Last Updated

  • Oct. 31, 2016, 7:45 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 5

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Hartwig, Troy; Hower, Brent & Seaholm, Aaron. Adjustable Shock Test Sled for Haversine Pulses at 250 fps, article, May 5, 2008; United States. (digital.library.unt.edu/ark:/67531/metadc897943/: accessed December 13, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.