Sludge Batch 5 Slurry Fed Melt Rate Furnace Test with Frits 418 and 550 Page: 1 of 27
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
SRNL-STI-2008-00508, REVISION 0
Key Words:
Melt Rate, SB5,
DWPF, glass
Retention:
Permanent
SLUDGE BATCH 5 SLURRY FED MELT RATE FURNACE TESTS
WITH FRITS 418 AND 550
D. H. Miller
B. R. Pickenheim
DECEMBER 2008Savannah River National Laboratory
Savannah River Nuclear Solutions
Aiken. SC 29808
Prepared for the U.S. Department of Energy Under
Contract Number DE-AC09-08SR22470M SAVANNAH RIVER NATIONAL LABORATORY
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Miller, Donald & Pickenheim, Bradley. Sludge Batch 5 Slurry Fed Melt Rate Furnace Test with Frits 418 and 550, report, February 11, 2009; Aiken, South Carolina. (https://digital.library.unt.edu/ark:/67531/metadc896508/m1/1/: accessed April 22, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.