The U.S. magnetic fusion energy program has developed a single design long pulse neutral beam source for TFTR, MFTF-B, and DIII-D. The arc is a very compact axial magnetic line cusp. The accelerator is an actively cooled tetrode with water cooled grid tubes of shaped molybdenum forming 'slot' beamlets. DIII-D and MFTF-B configurations have an 80 kV accelerator gap, with 12 x 48 cm aperture, and a 10 meter 'module' focus. TFTR modules are unfocused, with a 120 kV gap and 12 x 43 cm mask. The first CLPS was tested in the TFTR configuration, at 120 kV, 2 seconds. ... continued below

Creation Information

Vella, M. C.; Cooper, W. S. & Pincosy, P. A. December 1, 1987.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The U.S. magnetic fusion energy program has developed a single design long pulse neutral beam source for TFTR, MFTF-B, and DIII-D. The arc is a very compact axial magnetic line cusp. The accelerator is an actively cooled tetrode with water cooled grid tubes of shaped molybdenum forming 'slot' beamlets. DIII-D and MFTF-B configurations have an 80 kV accelerator gap, with 12 x 48 cm aperture, and a 10 meter 'module' focus. TFTR modules are unfocused, with a 120 kV gap and 12 x 43 cm mask. The first CLPS was tested in the TFTR configuration, at 120 kV, 2 seconds. Optimum current was 73 Amperes, or 1.76 ppervs (deuterium), with 80% - 85% atomic fraction. Optimum divergence of ions plus neutrals was 0.4' parallel to the slots, and 0.7' perpendicular to the slots ( l / e half angle). The combination of an axial cusp magnetic bucket and slot accelerator apertures gives the CLPS about twice the beam power per unit cross section of other long pulse sources, plus lower divergence in the direction parallel to the slots.

Source

  • Journal Name: Review of Scientific Instruments; Journal Volume: 59; Journal Issue: 11; Related Information: Journal Publication Date: 11/1988

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: LBL--22530
  • Grant Number: DE-AC02-05CH11231
  • Office of Scientific & Technical Information Report Number: 919665
  • Archival Resource Key: ark:/67531/metadc896016

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • December 1, 1987

Added to The UNT Digital Library

  • Sept. 27, 2016, 1:39 a.m.

Description Last Updated

  • Sept. 30, 2016, 1:39 p.m.

Usage Statistics

When was this article last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Vella, M. C.; Cooper, W. S. & Pincosy, P. A. DEVELOPMENT TESTING OF THE U.S. COMMON LONG PULSE SOURCE AT 120KV, article, December 1, 1987; Berkeley, California. (digital.library.unt.edu/ark:/67531/metadc896016/: accessed October 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.