Description

We used the code PSUADE to calibrate Prout-Tompkins kinetic parameters for pure recrystallized TNT. The calibration was based on ALE3D simulations of a series of One Dimensional Time to Explosion (ODTX) experiments. The resultant kinetic parameters differed from TNT data points with an average error of 28%, which is slightly higher than the value of 23% previously calculated using a two-point optimization. The methodology described here provides a basis for future calibration studies using PSUADE. The files used in the procedure are listed in the Appendix.

Physical Description

PDF-file: 40 pages; size: 1.1 Mbytes

Creation Information

Wemhoff, A P & Hsieh, H April 11, 2007.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

We used the code PSUADE to calibrate Prout-Tompkins kinetic parameters for pure recrystallized TNT. The calibration was based on ALE3D simulations of a series of One Dimensional Time to Explosion (ODTX) experiments. The resultant kinetic parameters differed from TNT data points with an average error of 28%, which is slightly higher than the value of 23% previously calculated using a two-point optimization. The methodology described here provides a basis for future calibration studies using PSUADE. The files used in the procedure are listed in the Appendix.

Physical Description

PDF-file: 40 pages; size: 1.1 Mbytes

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: UCRL-TR-230194
  • Grant Number: W-7405-ENG-48
  • DOI: 10.2172/908909 | External Link
  • Office of Scientific & Technical Information Report Number: 908909
  • Archival Resource Key: ark:/67531/metadc888993

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 11, 2007

Added to The UNT Digital Library

  • Sept. 22, 2016, 2:13 a.m.

Description Last Updated

  • Dec. 7, 2016, 11:14 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Wemhoff, A P & Hsieh, H. TNT Prout-Tompkins Kinetics Calibration with PSUADE, report, April 11, 2007; Livermore, California. (digital.library.unt.edu/ark:/67531/metadc888993/: accessed August 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.