Parcperdue Geopressure -- Geothermal Project: Appendices (C--M)

PDF Version Also Available for Download.

Description

Twelve flow tests were made on the L. R. Sweezy No. 1 well. Short-term tests, Flow Test No.1 through Flow Test No.4 were designed to estimate formation properties and were conducted for drawdown periods measured in hours. Intermediate-term tests, Flow Test No.5 through Flow Test No.8, were for a few days and were designed to test for reservoir boundaries. Long-term tests, Flow Test No.9 through Flow Test No.12, were designed for drawdown periods of about 60 days in order to examine the depletion behavior of the reservoir.

Creation Information

Sweezy, L.R. October 5, 1981.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

  • USDOE
    Place of Publication: United States

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Twelve flow tests were made on the L. R. Sweezy No. 1 well. Short-term tests, Flow Test No.1 through Flow Test No.4 were designed to estimate formation properties and were conducted for drawdown periods measured in hours. Intermediate-term tests, Flow Test No.5 through Flow Test No.8, were for a few days and were designed to test for reservoir boundaries. Long-term tests, Flow Test No.9 through Flow Test No.12, were designed for drawdown periods of about 60 days in order to examine the depletion behavior of the reservoir.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: None
  • Grant Number: AC08-79ET27255
  • DOI: 10.2172/898331 | External Link
  • Office of Scientific & Technical Information Report Number: 898331
  • Archival Resource Key: ark:/67531/metadc888667

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 5, 1981

Added to The UNT Digital Library

  • Sept. 22, 2016, 2:13 a.m.

Usage Statistics

When was this report last used?

Congratulations! It looks like you are the first person to view this item online.

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Sweezy, L.R. Parcperdue Geopressure -- Geothermal Project: Appendices (C--M), report, October 5, 1981; United States. (digital.library.unt.edu/ark:/67531/metadc888667/: accessed August 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.