EVALUATION OF THE FAILURE OF A RADIOACTIVE WASTE TRANSFER LINE JACKET

PDF Version Also Available for Download.

Description

Radioactive wastes are confined in 49 underground storage tanks at the Savannah River Site. The waste is transported between tanks primarily via an underground transfer piping system. Due to the hazardous nature of the waste, the inner core stainless steel pipe is typically surrounded by a carbon steel pipe jacket, which provides secondary containment. Recently several through-wall penetrations were discovered on a segment of one of the jackets. An evaluation was performed to verify the failure mechanism and to estimate the degree of damage that occurred to the pipe segment. Failure analysis of a section of the jacket confirmed that ... continued below

Creation Information

Wiersma, B; Alan03 Plummer, A; Karthik Subramanian, K; Charles Jenkins, C; William Hinz, W & A Fellinger, A April 6, 2007.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Radioactive wastes are confined in 49 underground storage tanks at the Savannah River Site. The waste is transported between tanks primarily via an underground transfer piping system. Due to the hazardous nature of the waste, the inner core stainless steel pipe is typically surrounded by a carbon steel pipe jacket, which provides secondary containment. Recently several through-wall penetrations were discovered on a segment of one of the jackets. An evaluation was performed to verify the failure mechanism and to estimate the degree of damage that occurred to the pipe segment. Failure analysis of a section of the jacket confirmed that pitting corrosion on the exterior of the pipe led to the through-wall penetration. Ultrasonic measurements on sections of the pipe were utilized to determine the remaining wall thickness in adjacent areas of the pipe. Based on these measurements, the degree of pitting and general corrosion was determined. Pit growth rate models were then developed to estimate the life expectancy of sections of the pipe that had not been excavated. The calculations estimated that the occurrence of through-wall failures in this jacket will begin to increase substantially in 12 years. Given that this pipe segment will be utilized beyond this time, short-term and long-term solutions to this failure were proposed. The short-term solutions focused on the repair or replace decisions that must be made to return the jacket to service as soon as practical. The long-term solutions focused on a broader strategy to address jacket integrity issues in the entire tank farm facility. These solutions included the evaluation of innovative remote inspection and repair techniques.

Notes

available

Source

  • ASME PVP 2007/CREEP 8 Conference

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: WSRC-STI-2006-00327
  • Grant Number: DE-AC09-96SR18500
  • Office of Scientific & Technical Information Report Number: 903091
  • Archival Resource Key: ark:/67531/metadc887927

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • April 6, 2007

Added to The UNT Digital Library

  • Sept. 22, 2016, 2:13 a.m.

Description Last Updated

  • Nov. 2, 2016, 12:49 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 5

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Wiersma, B; Alan03 Plummer, A; Karthik Subramanian, K; Charles Jenkins, C; William Hinz, W & A Fellinger, A. EVALUATION OF THE FAILURE OF A RADIOACTIVE WASTE TRANSFER LINE JACKET, article, April 6, 2007; [Aiken, South Carolina]. (digital.library.unt.edu/ark:/67531/metadc887927/: accessed December 14, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.